Correction of specimen orientation in three-dimensional measurement of surface roughness with small waviness by contact stylus instrument (2nd report) : simulation and experimental verification
{"title":"Correction of specimen orientation in three-dimensional measurement of surface roughness with small waviness by contact stylus instrument (2nd report) : simulation and experimental verification","authors":"N. Cho, T. Tsukada, M. Takahashi","doi":"10.2493/JJSPE.60.549","DOIUrl":null,"url":null,"abstract":"In this paper, the method I is compared with the method II. The method I is developed in the 1st report to control surface orientation by using two measuring lines perpendicular to each other and the method II by two parallel measuring lines. The results are as follows . (1)The measuring length for control data in the method I increases for anisotropic rough surface under the condition that the angle between measuring direction and lay orientation of asperities is less than 15•K . (2)The measuring length for control data in the method II decreases as the coefficient k2 depending on a stylus speed decreases. (3)Both of the measuring length and the objective function showing measuring time in the method II are shorter than those in the method I for isotropic and anisotropic rough surfaces . Finally, the method II is better technique than the method I .","PeriodicalId":14336,"journal":{"name":"International Journal of The Japan Society for Precision Engineering","volume":"4 1","pages":"253-258"},"PeriodicalIF":0.0000,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of The Japan Society for Precision Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2493/JJSPE.60.549","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this paper, the method I is compared with the method II. The method I is developed in the 1st report to control surface orientation by using two measuring lines perpendicular to each other and the method II by two parallel measuring lines. The results are as follows . (1)The measuring length for control data in the method I increases for anisotropic rough surface under the condition that the angle between measuring direction and lay orientation of asperities is less than 15•K . (2)The measuring length for control data in the method II decreases as the coefficient k2 depending on a stylus speed decreases. (3)Both of the measuring length and the objective function showing measuring time in the method II are shorter than those in the method I for isotropic and anisotropic rough surfaces . Finally, the method II is better technique than the method I .