Life Cycle Water Use for Oxy Fuel Combustion Power Generation with CO2 Capture and Storage

M. Jalal, Q. Yang, Chen Mengxi
{"title":"Life Cycle Water Use for Oxy Fuel Combustion Power Generation with CO2 Capture and Storage","authors":"M. Jalal, Q. Yang, Chen Mengxi","doi":"10.12783/dteees/iceee2019/31758","DOIUrl":null,"url":null,"abstract":"The water scarcity is becoming a growing concern. Regarded as a potential CO emission mitigation technology for coal-fired power plants, oxy-fuel combustion, a typical CCS technology, theoretically consumes a large amount of water, which increases the severity of the water scarcity. Therefore, revealing the water use of oxy-fuel coal-fired power plants is of great importance for the deployment of CCS technologies under water resource constraint in the future. In this respect, the aim of this study is to evaluate the life cycle water use of oxy-fuel CO capture, transport and storage via a 600 MW coal fired oxy-fuel power plant in China. By using a tiered hybrid life cycle assessment, both direct and indirect water use are calculated. Results show 22.9L H O/kg of CO and the oxy-fuel power plant stage dominates the total water use, while the water intensity for power generation is calculated as 3233.3 L H O/MWh, which is higher than the conventional power plants. Sensitivity analysis is performed in this research and indicates that the variation of tap water use affects the water intensity immensely. Furthermore, the use of the membrane method for air separation decreases the overall water use 14.21% respectively. China is continually increasing its efforts to reduce carbon emissions due to both domestic and international pressure. Hence the development and implement of the CCS technology is of great urgency. At the end of this study possible solutions such as using wasted or discarded wind power for the separation of oxygen to minimize water use in oxy-fuel power plant stage are put forward.","PeriodicalId":11324,"journal":{"name":"DEStech Transactions on Environment, Energy and Earth Sciences","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"DEStech Transactions on Environment, Energy and Earth Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12783/dteees/iceee2019/31758","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The water scarcity is becoming a growing concern. Regarded as a potential CO emission mitigation technology for coal-fired power plants, oxy-fuel combustion, a typical CCS technology, theoretically consumes a large amount of water, which increases the severity of the water scarcity. Therefore, revealing the water use of oxy-fuel coal-fired power plants is of great importance for the deployment of CCS technologies under water resource constraint in the future. In this respect, the aim of this study is to evaluate the life cycle water use of oxy-fuel CO capture, transport and storage via a 600 MW coal fired oxy-fuel power plant in China. By using a tiered hybrid life cycle assessment, both direct and indirect water use are calculated. Results show 22.9L H O/kg of CO and the oxy-fuel power plant stage dominates the total water use, while the water intensity for power generation is calculated as 3233.3 L H O/MWh, which is higher than the conventional power plants. Sensitivity analysis is performed in this research and indicates that the variation of tap water use affects the water intensity immensely. Furthermore, the use of the membrane method for air separation decreases the overall water use 14.21% respectively. China is continually increasing its efforts to reduce carbon emissions due to both domestic and international pressure. Hence the development and implement of the CCS technology is of great urgency. At the end of this study possible solutions such as using wasted or discarded wind power for the separation of oxygen to minimize water use in oxy-fuel power plant stage are put forward.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
含氧燃料燃烧发电与二氧化碳捕集与封存的生命周期用水
水资源短缺正成为一个日益令人担忧的问题。全氧燃烧作为典型的CCS技术,在理论上消耗大量的水,增加了水资源短缺的严重程度,被认为是一种有潜力的燃煤电厂CO减排技术。因此,揭示全氧燃煤电厂的用水情况,对于未来水资源约束下CCS技术的部署具有重要意义。在这方面,本研究的目的是通过中国一座600兆瓦的燃煤全氧电厂来评估全氧燃料CO捕集、运输和储存的生命周期用水量。通过分层混合生命周期评估,计算了直接和间接用水量。结果表明:CO为22.9L H O/kg,全氧火力发电厂阶段占总用水量的主导地位,发电用水强度为3233.3 L H O/MWh,高于常规火力发电厂;本研究进行了敏感性分析,结果表明自来水用量的变化对水强度的影响很大。此外,采用膜法进行空气分离的总用水量分别降低了14.21%。由于国内和国际的压力,中国正在不断加大减少碳排放的努力。因此,开发和实施CCS技术刻不容缓。在本研究的最后,提出了可能的解决方案,如利用废弃或废弃的风力发电进行氧分离,以尽量减少氧燃料发电厂阶段的用水量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Research on Environmental Performance Evaluation of Petrochemical Enterprises Based on Balanced Scorecard-Entropy Method Measurement and Numerical Simulation Analysis of Smoke Flow Field after Dust Collector Modification Research on Collaborative Filtering Recommendation Algorithm Based on Mahout Preparation of Ultrafine -Al2O3 Powder from Fly Ash by Ammonium Sulfate Roasting Technology Design of Dual Mode Power Supply Distribution Circuit with Detection and Control Functions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1