The Additional Diagnostic Value of Electrocardiogram and Strain Patterns in Transplanted Patients

Decis. Sci. Pub Date : 2023-08-25 DOI:10.3390/sci5030034
L. Stefani, Goffredo Orlandi, M. Corsi, Edoardo Falconi, Roberto Palazzo, A. Pellegrino, P. Modesti
{"title":"The Additional Diagnostic Value of Electrocardiogram and Strain Patterns in Transplanted Patients","authors":"L. Stefani, Goffredo Orlandi, M. Corsi, Edoardo Falconi, Roberto Palazzo, A. Pellegrino, P. Modesti","doi":"10.3390/sci5030034","DOIUrl":null,"url":null,"abstract":"Background: Transplanted patients are frail individuals who may be affected by diastolic dysfunction, leading to a decrease in exercise tolerance. Previous studies have reported that certain ECG and echocardiographic parameters (such as the P-wave interval, PQ interval, P-wave dispersion, Tend-P interval, QTc interval, and strain) can support the diagnosis of diastolic dysfunction when the ejection fraction is preserved. This study aimed to examine the potential diagnostic contribution of specific ECG and deformation parameters in transplanted recipients, who are at a high risk of heart failure. Materials and Methods: A group of 33 transplanted subjects (17 renal and 16 liver) were categorized using two scores for heart failure with preserved ejection fraction (HFpEF). Additionally, they underwent evaluation based on ECG parameters (P-wave interval, PQ interval, Pwave dispersion, and Tend-P QTc) and echocardiographic deformation parameters (strain and twist). The Student’s t-test was used for statistical analysis. Results: The two scores identified different numbers of excludable and not excludable subjects potentially affected by HFpEF. The not excludable group presented ECG parameters with significantly higher values (P-wave, PQ interval, posterior wall diastole, and Tend-P, all with p ≤ 0.05) and significantly lower 4D strain and twist values (p < 0.05) Conclusions: There is evidence for a significant diagnostic contribution of additional ECG and echo strain parameters in an early phase of diastolic dysfunction in subjects potentially affected by HFpEF.","PeriodicalId":10987,"journal":{"name":"Decis. Sci.","volume":"2 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Decis. Sci.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/sci5030034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Transplanted patients are frail individuals who may be affected by diastolic dysfunction, leading to a decrease in exercise tolerance. Previous studies have reported that certain ECG and echocardiographic parameters (such as the P-wave interval, PQ interval, P-wave dispersion, Tend-P interval, QTc interval, and strain) can support the diagnosis of diastolic dysfunction when the ejection fraction is preserved. This study aimed to examine the potential diagnostic contribution of specific ECG and deformation parameters in transplanted recipients, who are at a high risk of heart failure. Materials and Methods: A group of 33 transplanted subjects (17 renal and 16 liver) were categorized using two scores for heart failure with preserved ejection fraction (HFpEF). Additionally, they underwent evaluation based on ECG parameters (P-wave interval, PQ interval, Pwave dispersion, and Tend-P QTc) and echocardiographic deformation parameters (strain and twist). The Student’s t-test was used for statistical analysis. Results: The two scores identified different numbers of excludable and not excludable subjects potentially affected by HFpEF. The not excludable group presented ECG parameters with significantly higher values (P-wave, PQ interval, posterior wall diastole, and Tend-P, all with p ≤ 0.05) and significantly lower 4D strain and twist values (p < 0.05) Conclusions: There is evidence for a significant diagnostic contribution of additional ECG and echo strain parameters in an early phase of diastolic dysfunction in subjects potentially affected by HFpEF.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
移植患者心电图和应变图的附加诊断价值
背景:移植患者是虚弱的个体,可能受到舒张功能障碍的影响,导致运动耐量下降。已有研究报道,在保留射血分数的情况下,某些心电图和超声心动图参数(如p波间期、PQ间期、p波弥散度、Tend-P间期、QTc间期和应变)可以支持舒张功能障碍的诊断。本研究旨在检查特定ECG和变形参数对移植受者的潜在诊断贡献,这些受者有心力衰竭的高风险。材料与方法:33例移植患者(17例肾移植,16例肝移植)采用保留射血分数(HFpEF)对心力衰竭进行评分。此外,根据心电图参数(p波间隔、PQ间隔、p波弥散和Tend-P QTc)和超声心动图变形参数(应变和扭转)对患者进行评估。采用学生t检验进行统计分析。结果:两种评分确定了可能受HFpEF影响的可排除性和不可排除性受试者的不同数量。非排除组心电图参数值(p波、PQ间期、后壁舒张、Tend-P值均p≤0.05)显著升高,4D应变和扭转值显著降低(p < 0.05)。结论:在HFpEF可能影响患者的舒张功能障碍早期,附加心电图和回声应变参数有重要的诊断价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Privacy and Security of Blockchain in Healthcare: Applications, Challenges, and Future Perspectives Digital Twins in Manufacturing: A RAMI 4.0 Compliant Concept In Silico Study of Potential Small Molecule TIPE2 Inhibitors for the Treatment of Cancer Treatment of Diabetes Mellitus by Acupuncture: Dynamics of Blood Glucose Level and Its Mathematical Modelling T5 for Hate Speech, Augmented Data, and Ensemble
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1