TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector

E. Albuquerque, R. Bugalho, V. Dubceac, L. Ferramacho, H. França, M. Firlej, T. Fiutowski, M. Gallinaro, M. Idzik, J. Moroń, T. Niknejad, L. Oliveira, R. Francisco, J. C. Silva, R. Silva, M. Silveira, K. Swientek, J. Varela
{"title":"TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector","authors":"E. Albuquerque, R. Bugalho, V. Dubceac, L. Ferramacho, H. França, M. Firlej, T. Fiutowski, M. Gallinaro, M. Idzik, J. Moroń, T. Niknejad, L. Oliveira, R. Francisco, J. C. Silva, R. Silva, M. Silveira, K. Swientek, J. Varela","doi":"10.1109/NSS/MIC42677.2020.9507749","DOIUrl":null,"url":null,"abstract":"The CMS Detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30–40 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected at the beginning of HL-LHC operation. We present an overview of the TOFHIR2 requirements and design, simulation results and the first measurements with TOFHIR2A silicon samples.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"22 21 1","pages":"1-7"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSS/MIC42677.2020.9507749","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

The CMS Detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30–40 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected at the beginning of HL-LHC operation. We present an overview of the TOFHIR2 requirements and design, simulation results and the first measurements with TOFHIR2A silicon samples.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
TOFHIR2: CMS桶状MIP定时检测器的读出专用集成电路
CMS探测器将为HL-LHC升级,包括MIP定时探测器(MTD)。MTD将由管状定时层和端盖定时层组成,分别为BTL和ETL,提供带电粒子的精确定时。BTL传感器是基于LYSO:Ce闪烁晶体耦合到SiPMs与TOFHIR2 asic的前端读出。预计在HL-LHC开始运行时,MIP信号的分辨率为30-40 ps,每通道速率为2.5 Mhit/s。我们概述了TOFHIR2的要求和设计,模拟结果和TOFHIR2A硅样品的首次测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance of Dual-Ended Readout PET Detectors Based on SiPMs with Different Microcell Sizes Neural Network-based Inter-crystal Scatter Event Positioning in a PET System Design Based on 3D Position Sensitive Detectors An e-LINAC driven PGNAA system for concealed drug inspection Design of a Multi-Technology Pre-Clinical SPECT System Comprehensive Simulation and Design of 3D Silicon Sensors for Enhanced Timing Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1