{"title":"Voltage stability enhancement during excess load increments through optimal location of UPFC devices","authors":"Aniruddha Ray, J. Chandle","doi":"10.1109/TAPENERGY.2015.7229660","DOIUrl":null,"url":null,"abstract":"Modern power systems are subjected to widespread line failures due to excess load demands, leading to voltage instability and voltage collapse. The objective of this paper is to study the application of Unified Power Flow Controller (UPFC) devices in improving voltage profile and controlling the power flowing through the transmission lines during excess load increments. Voltage Stability Analysis of the network is carried out by computing the eigen values of the power system reduced Jacobian matrix for each case of load increments before and after placing the UPFC device in the system. The line outage for which we get maximum number of critical eigen values is termed as the critical line outage. Voltage Stability Index is computed for each line corresponding to this critical outage. The line which has got the highest VSI for the critical outage is called as the critical line which indicates the optimal location of UPFC device. After placing the UPFC device on the critical line, the voltage magnitudes of the severely affected buses for this critical load increments is compared with those magnitudes during the critical outage.. The proposed approach is demonstrated on the IEEE 14 bus system in Matlab PSAT( Power system analysis Toolbox) software. The results obtained shows that UPFC devices improves the voltage profile of the buses and controls both active and reactive power flows across the transmission lines thus, preventing their outages during excess load demands and making the power system network voltage stable.","PeriodicalId":6552,"journal":{"name":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","volume":"24 1","pages":"443-448"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TAPENERGY.2015.7229660","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Modern power systems are subjected to widespread line failures due to excess load demands, leading to voltage instability and voltage collapse. The objective of this paper is to study the application of Unified Power Flow Controller (UPFC) devices in improving voltage profile and controlling the power flowing through the transmission lines during excess load increments. Voltage Stability Analysis of the network is carried out by computing the eigen values of the power system reduced Jacobian matrix for each case of load increments before and after placing the UPFC device in the system. The line outage for which we get maximum number of critical eigen values is termed as the critical line outage. Voltage Stability Index is computed for each line corresponding to this critical outage. The line which has got the highest VSI for the critical outage is called as the critical line which indicates the optimal location of UPFC device. After placing the UPFC device on the critical line, the voltage magnitudes of the severely affected buses for this critical load increments is compared with those magnitudes during the critical outage.. The proposed approach is demonstrated on the IEEE 14 bus system in Matlab PSAT( Power system analysis Toolbox) software. The results obtained shows that UPFC devices improves the voltage profile of the buses and controls both active and reactive power flows across the transmission lines thus, preventing their outages during excess load demands and making the power system network voltage stable.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过UPFC设备的最佳位置,在过载增量期间增强电压稳定性
现代电力系统普遍存在因负荷过大而导致的线路故障,从而导致电压不稳定和电压崩溃。本文的目的是研究统一潮流控制器(UPFC)装置在改善电压分布和控制过载增量时通过输电线路的功率方面的应用。通过计算UPFC设备放入系统前后各负荷增量情况下电力系统约简雅比矩阵的特征值,对网络进行电压稳定性分析。临界特征值数目最大的线路中断称为临界线路中断。电压稳定指数计算对应于这一关键停电的每条线路。临界停机时VSI值最高的线路称为临界线,表示UPFC设备的最佳位置。在将UPFC设备放置在关键线上后,将此关键负载增量的严重受影响总线的电压值与关键停电期间的电压值进行比较。该方法在IEEE 14总线系统上用Matlab PSAT(Power system analysis Toolbox)软件进行了验证。结果表明,UPFC设备改善了母线的电压分布,控制了输电线路上的有功和无功功率流,从而防止了在过载需求时母线的中断,使电网电压稳定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Reduction of common mode voltage in three phase inverter A novel topology of forward-flyback PFC converter with constant on-time control Online benefit optimization in a liberalized/free microgrid market model UHVDC transmission with dedicated metallic return Bridgeless flyback converter for low power lighting application
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1