{"title":"Uncertainties in the measurement of relative doses in radiotherapy","authors":"K. Buliński, T. Kuszewski, K. Wnuk, J. Braziewicz, K. Slosarek","doi":"10.2478/pjmpe-2021-0001","DOIUrl":null,"url":null,"abstract":"Abstract Both the measurement of the dose and the measurement of its distribution, like any other measurements, are subject to measurement uncertainties. These uncertainties affect all dose calculations and dose distributions in a patient’s body during treatment planning in radiotherapy. Measurement uncertainty is not a medical physicist’s error, but an inevitable element of their work. Planning the dose distribution in a patient’s body, we often try to reduce it in the volume of critical organs (OaR - Organ at Risk) or increase the minimum dose in the PTV region by a few percent. It is believed that the measurement uncertainty should be taken into account in these calculations at the stage of treatment planning. The paper presents the method of calculating the measurement uncertainty for different physical quantities in radiotherapy as percentage depth dose, profile function and output factor, due to the fact that these quantities have a particular impact on the calculated dose distributions in a patient’s body. The uncertainties that must be taken into account in planning treatment the planned dose per fraction and real in PTV, maybe different up to 4%.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"1 1","pages":"1 - 9"},"PeriodicalIF":0.7000,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Medical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/pjmpe-2021-0001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract Both the measurement of the dose and the measurement of its distribution, like any other measurements, are subject to measurement uncertainties. These uncertainties affect all dose calculations and dose distributions in a patient’s body during treatment planning in radiotherapy. Measurement uncertainty is not a medical physicist’s error, but an inevitable element of their work. Planning the dose distribution in a patient’s body, we often try to reduce it in the volume of critical organs (OaR - Organ at Risk) or increase the minimum dose in the PTV region by a few percent. It is believed that the measurement uncertainty should be taken into account in these calculations at the stage of treatment planning. The paper presents the method of calculating the measurement uncertainty for different physical quantities in radiotherapy as percentage depth dose, profile function and output factor, due to the fact that these quantities have a particular impact on the calculated dose distributions in a patient’s body. The uncertainties that must be taken into account in planning treatment the planned dose per fraction and real in PTV, maybe different up to 4%.
期刊介绍:
Polish Journal of Medical Physics and Engineering (PJMPE) (Online ISSN: 1898-0309; Print ISSN: 1425-4689) is an official publication of the Polish Society of Medical Physics. It is a peer-reviewed, open access scientific journal with no publication fees. The issues are published quarterly online. The Journal publishes original contribution in medical physics and biomedical engineering.