Évaluation clinique d' un nouvel oxygenateur a membrane en chirurgie cardiaque pediatrique néonatale : Le Kid D1000

P. Pouard, R. Rambur, G. Allanic, L. Tourneur, S. Moreau, P. Vouhé
{"title":"Évaluation clinique d' un nouvel oxygenateur a membrane en chirurgie cardiaque pediatrique néonatale : Le Kid D1000","authors":"P. Pouard,&nbsp;R. Rambur,&nbsp;G. Allanic,&nbsp;L. Tourneur,&nbsp;S. Moreau,&nbsp;P. Vouhé","doi":"10.1016/S1297-9562(06)80006-9","DOIUrl":null,"url":null,"abstract":"<div><p>The authors have evaluated a new hollow fiber membrane oxygenator specially dedicated for neonatal cardiac surgery. The priming volume is optimized at 31 ml with a membrane surface area of 0.22 m2 for a maximum blood fow 0.71/min. The main finding of this evaluation is the ease with wick the management of blood gaz is possible. This new oxygenator allows to avoid hypocarbia and hyperoxia often observed during neonatal cardiopulmonary bypass.</p></div>","PeriodicalId":100733,"journal":{"name":"ITBM-RBM","volume":"27 ","pages":"Pages S19-S21"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S1297-9562(06)80006-9","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ITBM-RBM","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1297956206800069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The authors have evaluated a new hollow fiber membrane oxygenator specially dedicated for neonatal cardiac surgery. The priming volume is optimized at 31 ml with a membrane surface area of 0.22 m2 for a maximum blood fow 0.71/min. The main finding of this evaluation is the ease with wick the management of blood gaz is possible. This new oxygenator allows to avoid hypocarbia and hyperoxia often observed during neonatal cardiopulmonary bypass.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种新型膜氧发生器在儿科新生儿心脏手术中的临床评价:Kid D1000
作者评价了一种专门用于新生儿心脏手术的新型中空纤维膜氧合器。启动体积优化为31 ml,膜表面积为0.22 m2,最大血流量为0.71/min。本评价的主要发现是易于用灯芯管理血气是可能的。这种新的氧合器可以避免新生儿体外循环过程中经常观察到的低碳和高氧。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Oxygéenateurs : évolution et nouveautés Oxygenators : evolution and update Sortie de CEC difficile : tableaux cliniques et modalités thérapeutiques Phase contact dans la réponse hémostatique et vasculaire vers un système intégré Place de l'aprotinine en chirurgie cardiaque Déficit acquis en Antithrombine et hemofiltration
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1