The association between the duration of using ocular prosthesis and upper and lower conjunctival fornix depth

Tari Adrian, R. R. Lubis, A. Arma
{"title":"The association between the duration of using ocular prosthesis and upper and lower conjunctival fornix depth","authors":"Tari Adrian, R. R. Lubis, A. Arma","doi":"10.5455/ijmsph.2020.08133202018082020","DOIUrl":null,"url":null,"abstract":"Background: Ocular prosthesis is needed to replace the content of eyeball lost due to several factors. Adequate retention of ocular prosthesis requires an adequate upper and lower conjunctival fornix depth. Objectives: The objectives of the study were to evaluate the association between the duration of using ocular prosthesis and upper and lower conjunctival fornix depth. Materials and Methods: A case–control study was conducted in 30 anophthalmic socket patients aged 22–77 that using ocular prosthesis more than 6 months. The contralateral eye with healthy socket was chosen as a control group. Upper and lower conjunctival fornix depth were measure using fornicometer. We design a fornix depth measurer for objective measurement of upper and lower conjunctival fornix depth. Results: From 30 anophthalmic socket patients, males were about 14 times more often than female, with the average age that was 51. The mean upper conjunctival fornix depth in males was 10.8 ± 0.6 and lower conjunctival fornix depth was 6.2 ± 0.8. The mean upper conjunctival fornix depth in females was 10.80± 0.6 and lower conjunctival fornix depth was 5.5 ± 0.7. There is medium relationship between upper conjunctival fornix depth and the duration of using prosthesis (cc = −0.435; P = 0.016) and there is high relationship between lower conjunctival fornix depth and the duration of using prosthesis (cc = −0.551; P = 0.002). Conclusions: There was a significant association between the duration of using ocular prosthesis and upper and lower conjunctival fornix depth.","PeriodicalId":14153,"journal":{"name":"International Journal of Medical Science and Public Health","volume":"49 1","pages":"444-448"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Science and Public Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5455/ijmsph.2020.08133202018082020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Ocular prosthesis is needed to replace the content of eyeball lost due to several factors. Adequate retention of ocular prosthesis requires an adequate upper and lower conjunctival fornix depth. Objectives: The objectives of the study were to evaluate the association between the duration of using ocular prosthesis and upper and lower conjunctival fornix depth. Materials and Methods: A case–control study was conducted in 30 anophthalmic socket patients aged 22–77 that using ocular prosthesis more than 6 months. The contralateral eye with healthy socket was chosen as a control group. Upper and lower conjunctival fornix depth were measure using fornicometer. We design a fornix depth measurer for objective measurement of upper and lower conjunctival fornix depth. Results: From 30 anophthalmic socket patients, males were about 14 times more often than female, with the average age that was 51. The mean upper conjunctival fornix depth in males was 10.8 ± 0.6 and lower conjunctival fornix depth was 6.2 ± 0.8. The mean upper conjunctival fornix depth in females was 10.80± 0.6 and lower conjunctival fornix depth was 5.5 ± 0.7. There is medium relationship between upper conjunctival fornix depth and the duration of using prosthesis (cc = −0.435; P = 0.016) and there is high relationship between lower conjunctival fornix depth and the duration of using prosthesis (cc = −0.551; P = 0.002). Conclusions: There was a significant association between the duration of using ocular prosthesis and upper and lower conjunctival fornix depth.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
眼假体使用时间与上、下结膜穹窿深度的关系
背景:由于多种因素导致眼球内容物丢失,需要人工眼。眼假体的充分保留需要足够的上、下结膜穹窿深度。目的:本研究的目的是评估眼假体使用时间与上、下结膜穹窿深度之间的关系。材料与方法:对30例22 ~ 77岁无眼窝且使用人工眼6个月以上的患者进行病例对照研究。选取正常眼窝的对侧眼作为对照组。采用穹窿计测量上、下结膜穹窿深度。我们设计了一种穹窿深度测量仪,用于客观测量上、下结膜穹窿深度。结果:30例眼窝无闭患者中,男性约为女性的14倍,平均年龄51岁。男性结膜上穹窿平均深度为10.8±0.6,下结膜穹窿平均深度为6.2±0.8。女性上结膜穹窿平均深度为10.80±0.6,下结膜穹窿平均深度为5.5±0.7。上结膜穹窿深度与假体使用时间呈中等相关性(cc =−0.435;P = 0.016),下结膜穹窿深度与假体使用时间高度相关(cc =−0.551;P = 0.002)。结论:眼假体使用时间与上、下结膜穹窿深度有显著相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Knowledge, attitude, and preventive behavior toward COVID-19 of high school students in Bangkok, Thailand: A study among students in harrow's international school Knowledge, attitude, and drug resistance preventive behaviors of high school students in Bangkok Effect of neurodynamic techniques on radiating symptoms and mechanosensitivity of neural tissue in subjects with lumbosacral radiculopathy: A double-blind randomized controlled trial Correlation of homocysteine and Vitamin B12 level as a surrogative marker for early detection of sensorineural hearing loss in children Mutations in genes onset the disease of cancer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1