Normal coronal kinematics of dynamic alignment and bony positions relative to the ground in three-dimensional motion analysis during gait: A preliminary study.
{"title":"Normal coronal kinematics of dynamic alignment and bony positions relative to the ground in three-dimensional motion analysis during gait: A preliminary study.","authors":"Yasuyuki Tomiyama, Tomoharu Mochizuki, Osamu Tanifuji, Katsutoshi Nishino, Masaei Tanaka, Go Omori, Noriaki Yamamoto, Hiroshi Koga, Yoshio Koga, Hiroyuki Kawashima","doi":"10.3233/BME-211383","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>During gait, healthy knee coronal kinematics of each bony axis and lower extremity alignment are important because they could be useful as reference data for several surgeries and provide clarification of the etiology of diseases around the knee in healthy participants; however, it remains unknown.</p><p><strong>Objective: </strong>The objective of this study was to clarify the kinematics of lower extremity alignment and the bony axes relative to the ground during gait, focused on the coronal plane, in healthy individuals by applying our unique three-dimensional (3D) motion analysis.</p><p><strong>Methods: </strong>The study included 21 healthy individuals, including 9 healthy females and 12 healthy males with an average age of 36 ± 17 years. Knee kinematics were calculated in a gait analysis by combining the data from a motion-capture system and a 3D lower-extremity alignment assessment system on biplanar long-leg radiographs by using a 3D-2D registration technique. The main kinematic parameters were the dynamic position change relative to the ground, applying the femoral anatomical axis (FAA), tibial anatomical axis (TAA), and dynamic alignment in the coronal plane during the stance phase of gait.</p><p><strong>Results: </strong>The average changes in FAA, TAA, and dynamic varus alignment were 3.7° ± 1.2°, 3.5° ± 0.8°, and 3.0° ± 1.2°, respectively. The TAA tilted laterally during the loading response and a plateau area appeared afterwards; the FAA gradually inclined laterally until the terminal stance phase, and the dynamic alignment showed varus angular change during the loading response.</p><p><strong>Conclusions: </strong>The tibia and femur were found to change approximately 2-5° of the position of the bony axes relative to the ground. In terms of clinical relevance, our findings can be used to clarify the etiology of diseases around the knee joint and as reference data for surgeries.</p>","PeriodicalId":9109,"journal":{"name":"Bio-medical materials and engineering","volume":"34 1","pages":"37-49"},"PeriodicalIF":1.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bio-medical materials and engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/BME-211383","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: During gait, healthy knee coronal kinematics of each bony axis and lower extremity alignment are important because they could be useful as reference data for several surgeries and provide clarification of the etiology of diseases around the knee in healthy participants; however, it remains unknown.
Objective: The objective of this study was to clarify the kinematics of lower extremity alignment and the bony axes relative to the ground during gait, focused on the coronal plane, in healthy individuals by applying our unique three-dimensional (3D) motion analysis.
Methods: The study included 21 healthy individuals, including 9 healthy females and 12 healthy males with an average age of 36 ± 17 years. Knee kinematics were calculated in a gait analysis by combining the data from a motion-capture system and a 3D lower-extremity alignment assessment system on biplanar long-leg radiographs by using a 3D-2D registration technique. The main kinematic parameters were the dynamic position change relative to the ground, applying the femoral anatomical axis (FAA), tibial anatomical axis (TAA), and dynamic alignment in the coronal plane during the stance phase of gait.
Results: The average changes in FAA, TAA, and dynamic varus alignment were 3.7° ± 1.2°, 3.5° ± 0.8°, and 3.0° ± 1.2°, respectively. The TAA tilted laterally during the loading response and a plateau area appeared afterwards; the FAA gradually inclined laterally until the terminal stance phase, and the dynamic alignment showed varus angular change during the loading response.
Conclusions: The tibia and femur were found to change approximately 2-5° of the position of the bony axes relative to the ground. In terms of clinical relevance, our findings can be used to clarify the etiology of diseases around the knee joint and as reference data for surgeries.
期刊介绍:
The aim of Bio-Medical Materials and Engineering is to promote the welfare of humans and to help them keep healthy. This international journal is an interdisciplinary journal that publishes original research papers, review articles and brief notes on materials and engineering for biological and medical systems. Articles in this peer-reviewed journal cover a wide range of topics, including, but not limited to: Engineering as applied to improving diagnosis, therapy, and prevention of disease and injury, and better substitutes for damaged or disabled human organs; Studies of biomaterial interactions with the human body, bio-compatibility, interfacial and interaction problems; Biomechanical behavior under biological and/or medical conditions; Mechanical and biological properties of membrane biomaterials; Cellular and tissue engineering, physiological, biophysical, biochemical bioengineering aspects; Implant failure fields and degradation of implants. Biomimetics engineering and materials including system analysis as supporter for aged people and as rehabilitation; Bioengineering and materials technology as applied to the decontamination against environmental problems; Biosensors, bioreactors, bioprocess instrumentation and control system; Application to food engineering; Standardization problems on biomaterials and related products; Assessment of reliability and safety of biomedical materials and man-machine systems; and Product liability of biomaterials and related products.