Diagnostic Value of T1 Mapping in Detecting Iron Overload in Indian Patients with Thalassemia Major: A Comparison with T2* Mapping.

Q4 Arts and Humanities Echa Przeszlosci Pub Date : 2023-09-04 eCollection Date: 2024-01-01 DOI:10.1055/s-0043-1772467
Surya Pratap Singh, Priya Jagia, Vineeta Ojha, Tulika Seth, Nitish Naik, Kartik P Ganga, Sanjeev Kumar
{"title":"Diagnostic Value of T1 Mapping in Detecting Iron Overload in Indian Patients with Thalassemia Major: A Comparison with T2* Mapping.","authors":"Surya Pratap Singh, Priya Jagia, Vineeta Ojha, Tulika Seth, Nitish Naik, Kartik P Ganga, Sanjeev Kumar","doi":"10.1055/s-0043-1772467","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose</b>  T2* is the gold standard for iron quantification in liver as well as myocardium. In this study, we evaluated the diagnostic accuracy of myocardial T1 mapping for the assessment of myocardial iron overload (MIO) as compared to the T2* mapping in patients with thalassemia major (TM). <b>Methods</b>  Consecutive TM patients attending the thalassemia clinic were prospectively enrolled. Magnetic resonance imaging was performed on a 1.5 T scanner (Siemens Healthineers, Germany) using a gradient echo T2* as well as a T1 mapping (MOLLI) sequence done at a mid-ventricular short-axis single 8 mm slice of the left ventricle. Values were analyzed by manually drawing a region of interest in the mid-septum. T2*less than 20ms was used as the cutoff for significant MIO. <b>Results</b>  One-hundred three patients (58 males, mean age: 17 ± 7.8 years, mean ferritin: 2009.5 µg/L) underwent cardiovascular magnetic resonance. Median T2* of myocardium was 33.45ms. Nineteen patients (18.4%) had T2*less than 20ms. T1 value was low (<850ms) in all the patients with T2* less than 20 ms. Receiver operating characteristic curve analysis revealed the best cutoff of native T1 mapping value as 850 ms which had high specificity (95.2%), sensitivity (94.2%) and negative predictive value (98.8%) for T2* less than 20ms. There was excellent agreement between T1 and T2* for diagnosis of MIO (Kappa-0.848, <i>p</i> <0.001). We did not find any patient who had normal T1 mapping values but had MIO on T2*. <b>Conclusion</b>  T1 and T2* correlate well and normal T1 values may rule out presence of MIO. T1 mapping can act as additional imaging marker for MIO and may be helpful in centers with nonavailability or limited experience of T2*.</p>","PeriodicalId":36993,"journal":{"name":"Echa Przeszlosci","volume":"1 1","pages":"54-59"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10723946/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Echa Przeszlosci","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1772467","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"Arts and Humanities","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose  T2* is the gold standard for iron quantification in liver as well as myocardium. In this study, we evaluated the diagnostic accuracy of myocardial T1 mapping for the assessment of myocardial iron overload (MIO) as compared to the T2* mapping in patients with thalassemia major (TM). Methods  Consecutive TM patients attending the thalassemia clinic were prospectively enrolled. Magnetic resonance imaging was performed on a 1.5 T scanner (Siemens Healthineers, Germany) using a gradient echo T2* as well as a T1 mapping (MOLLI) sequence done at a mid-ventricular short-axis single 8 mm slice of the left ventricle. Values were analyzed by manually drawing a region of interest in the mid-septum. T2*less than 20ms was used as the cutoff for significant MIO. Results  One-hundred three patients (58 males, mean age: 17 ± 7.8 years, mean ferritin: 2009.5 µg/L) underwent cardiovascular magnetic resonance. Median T2* of myocardium was 33.45ms. Nineteen patients (18.4%) had T2*less than 20ms. T1 value was low (<850ms) in all the patients with T2* less than 20 ms. Receiver operating characteristic curve analysis revealed the best cutoff of native T1 mapping value as 850 ms which had high specificity (95.2%), sensitivity (94.2%) and negative predictive value (98.8%) for T2* less than 20ms. There was excellent agreement between T1 and T2* for diagnosis of MIO (Kappa-0.848, p <0.001). We did not find any patient who had normal T1 mapping values but had MIO on T2*. Conclusion  T1 and T2* correlate well and normal T1 values may rule out presence of MIO. T1 mapping can act as additional imaging marker for MIO and may be helpful in centers with nonavailability or limited experience of T2*.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
T1 Mapping 在检测印度重型地中海贫血患者铁超载方面的诊断价值:与 T2* Mapping 的比较。
目的 T2*是肝脏和心肌铁定量的金标准。在这项研究中,我们评估了在重型地中海贫血(TM)患者中评估心肌铁负荷过重(MIO)的心肌 T1 图谱与 T2* 图谱的诊断准确性。方法 前瞻性地招募了在地中海贫血诊所就诊的连续重型地中海贫血患者。磁共振成像在 1.5 T 扫描仪(德国西门子 Healthineers 公司)上进行,使用梯度回波 T2* 和 T1 映射(MOLLI)序列在左心室中轴短轴单个 8 毫米切片上进行。通过在中隔手动绘制感兴趣区来分析数值。以 T2* 小于 20ms 作为明显 MIO 的临界值。结果 103名患者(58名男性,平均年龄:17 ± 7.8岁,平均铁蛋白:2009.5 µg/L)接受了心血管磁共振检查。心肌中位 T2* 为 33.45ms。19 名患者(18.4%)的 T2* 小于 20 毫秒。T1 值偏低(P 结论 T1 和 T2* 相互关系良好,正常的 T1 值可排除 MIO 的存在。T1 映射可作为 MIO 的额外成像标记,在没有 T2* 或 T2* 经验有限的中心可能会有所帮助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Echa Przeszlosci
Echa Przeszlosci Arts and Humanities-History
CiteScore
0.10
自引率
0.00%
发文量
14
期刊最新文献
Diagnostic Value of T1 Mapping in Detecting Iron Overload in Indian Patients with Thalassemia Major: A Comparison with T2* Mapping. An unfortunate ally of the United Arab Republic.The People’s National Army of the People’s Democratic Republic of Algeria during the 1967 Arab-Israeli war Влияние решений Замойского собора на формирование европейской ментальности в украинцев и белорусов Речи Посполитой – историография проблемы Communism and communists towards the intelligentsia in interwar Poland. An outline of the issue Участь українців австро-угорського підданства в Першій більшовицько-українській війні (січень–березень 1918 р.)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1