{"title":"Elastoplastic Quasi-Static and Impact Load Response of Steel Structure Sub-Assemblage with CFRP Strips","authors":"Ali Al Aloosi, Zia Razzaq","doi":"10.24018/ejeng.2023.8.2.2968","DOIUrl":null,"url":null,"abstract":"Presented in this paper is the outcome of an experimental investigation of the elastoplastic quasi-static and impact load response of a steel sub-assemblage constructed using a pair of hollow square section members with or without Carbon Fiber Reinforced Polymer (CFRP) strips. The sub-assemblage consists of a long structural member welded to a short member, thus representing a typical combination of a column and a beam on the face of a multi-story steel building frame. The column is subjected to a lateral quasi-static or impact load. Tests are conducted on four separate steel sub-assemblages. The first two tests are conducted with a gradually increasing flexural load applied at the midspan of the column up to the collapse condition without and with CFRP strips, respectively. Additional two tests are performed with a flexural impact load applied at midspan of the column also both without and with CFRP strips, respectively. The results of the study show that CFRP strips substantially increase the quasi-static collapse load of the sub-assemblage. However, when subjected to an impact load, the steel structure sub-assemblage with CFRP strips developed smaller strains in comparison with those without the CFRP strips. The post-impact time-dependent strains also became considerably smaller for the sub-assemblage with CFRP strips.","PeriodicalId":12001,"journal":{"name":"European Journal of Engineering and Technology Research","volume":"33 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Engineering and Technology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24018/ejeng.2023.8.2.2968","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Presented in this paper is the outcome of an experimental investigation of the elastoplastic quasi-static and impact load response of a steel sub-assemblage constructed using a pair of hollow square section members with or without Carbon Fiber Reinforced Polymer (CFRP) strips. The sub-assemblage consists of a long structural member welded to a short member, thus representing a typical combination of a column and a beam on the face of a multi-story steel building frame. The column is subjected to a lateral quasi-static or impact load. Tests are conducted on four separate steel sub-assemblages. The first two tests are conducted with a gradually increasing flexural load applied at the midspan of the column up to the collapse condition without and with CFRP strips, respectively. Additional two tests are performed with a flexural impact load applied at midspan of the column also both without and with CFRP strips, respectively. The results of the study show that CFRP strips substantially increase the quasi-static collapse load of the sub-assemblage. However, when subjected to an impact load, the steel structure sub-assemblage with CFRP strips developed smaller strains in comparison with those without the CFRP strips. The post-impact time-dependent strains also became considerably smaller for the sub-assemblage with CFRP strips.