Development of Two Simple Spectrophotometric Methods to Assay Phenylephrine-HCl as Pure Form And in Its Drug Forms

Hanan Hameed, Salim Ali
{"title":"Development of Two Simple Spectrophotometric Methods to Assay Phenylephrine-HCl as Pure Form And in Its Drug Forms","authors":"Hanan Hameed, Salim Ali","doi":"10.18596/jotcsa.1260666","DOIUrl":null,"url":null,"abstract":"This work includes the development of two spectrophotometric methods which are sensitive, accurate, stable, and has good recovery for the determination of phenylephrine-HCl as free form and in the pharmaceutical preparations. In the method (A), phenylephrine is oxidized by potassium permanganate in a basic solution of sodium hydroxide and the bluish-green color of the resulting manganate (MnO 42- ) is measured at wavelength 610 nm, which is linearly proportional to the amount of phenylephrine-HCl. Method (B), is involved the oxidation of phenylephrine-HCl by using an excess amount of N-bromosuccinimide in an acidic medium of hydrochloric acid solution, the remaining (unreacted) amount of N-bromosuccinimide is used to bleach indigo carmine dye and the absorbance of the blue color of the remaining dye is measured at the wavelength of 610 nm. which is directly proportional to the concentration of phenylephrine-HCl. The molar absorptivity coefficients of methods (A) and (B) are estimated and equal to 1.5722×10 4 and 5.5191×10 4 L/mol.cm, respectively. Beer’s law of the both methods are linear in the concentration ranges 0.2–8.0 µg/mL (method A) and 0.2–3.5 µg/mL (method B). The relative standard deviation values of methods (A) and (B) are also found to be better than 0.0286 and 0.0114, respectively. The two proposed methods are applied to estimate phenylephrine-HCl in injection and drop.","PeriodicalId":17299,"journal":{"name":"Journal of the Turkish Chemical Society Section A: Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Turkish Chemical Society Section A: Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18596/jotcsa.1260666","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work includes the development of two spectrophotometric methods which are sensitive, accurate, stable, and has good recovery for the determination of phenylephrine-HCl as free form and in the pharmaceutical preparations. In the method (A), phenylephrine is oxidized by potassium permanganate in a basic solution of sodium hydroxide and the bluish-green color of the resulting manganate (MnO 42- ) is measured at wavelength 610 nm, which is linearly proportional to the amount of phenylephrine-HCl. Method (B), is involved the oxidation of phenylephrine-HCl by using an excess amount of N-bromosuccinimide in an acidic medium of hydrochloric acid solution, the remaining (unreacted) amount of N-bromosuccinimide is used to bleach indigo carmine dye and the absorbance of the blue color of the remaining dye is measured at the wavelength of 610 nm. which is directly proportional to the concentration of phenylephrine-HCl. The molar absorptivity coefficients of methods (A) and (B) are estimated and equal to 1.5722×10 4 and 5.5191×10 4 L/mol.cm, respectively. Beer’s law of the both methods are linear in the concentration ranges 0.2–8.0 µg/mL (method A) and 0.2–3.5 µg/mL (method B). The relative standard deviation values of methods (A) and (B) are also found to be better than 0.0286 and 0.0114, respectively. The two proposed methods are applied to estimate phenylephrine-HCl in injection and drop.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
两种简单分光光度法测定盐酸苯肾上腺素的纯态和剂型
建立了两种灵敏、准确、稳定、回收率高的分光光度法测定游离形态盐酸苯肾上腺素和制剂中的盐酸苯肾上腺素。在方法(A)中,苯肾上腺素在氢氧化钠的碱性溶液中被高锰酸钾氧化,在波长610 nm处测量得到的锰酸盐(mno42 -)的蓝绿色,该波长与苯肾上腺素- hcl的量成线性比例。方法(B),在盐酸溶液的酸性介质中使用过量的n -溴代琥珀酰亚胺氧化盐酸苯甲素,用剩余(未反应的)n -溴代琥珀酰亚胺漂白靛蓝胭脂红染料,在波长610 nm处测量剩余染料的蓝色吸光度。它与盐酸苯肾上腺素的浓度成正比。方法(A)和(B)的摩尔吸收系数分别为1.5722×10 4和5.5191×10 4 L/mol。厘米,分别。两种方法的Beer’s定律在0.2 ~ 8.0µg/mL(方法A)和0.2 ~ 3.5µg/mL(方法B)的浓度范围内均呈线性关系,方法A和方法B的相对标准偏差值分别优于0.0286和0.0114。应用这两种方法对盐酸苯肾上腺素注射液和滴剂进行了评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Microdetermination of Piroxicam in Pharmaceutical Formulations by Complexation with Fe(III) and Image Scanning Densitometry New Generation Nanoadsorbents and Conventional Techniques for Arsenic Removal from Waters Enhancing Biogas Production with The Addition of Nano-catalysts Degradation of Tolonium Chloride Dye by Phosphate Ion in Aqueous Acidic Solution: Kinetic Approach Preparation of Poly (N-Isopropylacrylamide) -Poly (2-Ethyl-2-Oxazoline) and Their Self-Assembly Properties with Dicarboxylic Acid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1