{"title":"Efficacy of a novel polyoxazoline-based hemostatic patch in liver and spleen surgery.","authors":"Edwin A Roozen,&nbsp;Roger M L M Lomme,&nbsp;Nicole U B Calon,&nbsp;Richard P G Ten Broek,&nbsp;Harry van Goor","doi":"10.1186/s13017-023-00483-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>A new hemostatic sealant based on a N-hydroxy-succinimide polyoxazoline (NHS-POx) polymer was evaluated to determine hemostatic efficacy and long-term wound healing and adverse effects in a large animal model of parenchymal organ surgical bleeds.</p><p><strong>Methods: </strong>Experiment 1 included 20 pigs that were treated with two NHS-POx patch prototypes [a gelatin fibrous carrier (GFC) with NHS-POx and an oxidized regenerated cellulose (ORC) with poly(lactic-co-glycolic acid)-NHS-POx:NU-POx (nucleophilically activated polyoxazoline)], a blank gelatin patch (GFC Blank), TachoSil<sup>®</sup> and Veriset™ to stop moderate liver and spleen punch bleedings. After various survival periods (1-6 weeks), pigs were re-operated to evaluate patch degradation and parenchymal healing. During the re-operation, experiment 2 was performed: partial liver and spleen resections with severe bleeding, and hemostatic efficacy was evaluated under normal and heparinized conditions of the two previous prototypes and one additional NHS-POx patch. In the third experiment an improved NHS-POx patch (GATT-Patch; GFC-NHS-POx and added 20% as nucleophilically activated polyoxazoline; NU-POx) was compared with TachoSil<sup>®</sup>, Veriset™ and GFC Blank on punch bleedings and partial liver and spleen resections for rapid (10s) hemostatic efficacy.</p><p><strong>Results: </strong>NHS-POx-based patches showed better (GFC-NHS-POx 83.1%, ORC-PLGA-NHS-POx: NU-POx 98.3%) hemostatic efficacy compared to TachoSil<sup>®</sup> (25.0%) and GFC Blank (43.3%), and comparable efficacy with Veriset™ (96.7%) on moderate standardized punch bleedings on liver and spleen. All patches demonstrated gradual degradation over 6 weeks with a reduced local inflammation rate and an improved wound healing. For severe bleedings under non-heparinized conditions, hemostasis was achieved in 100% for Veriset™, 40% for TachoSil and 80-100% for the three NHS-POx prototypes; similar differences between patches remained for heparinized conditions. In experiment 3, GATT-Patch, Veriset™, TachoSil and GFC Blank reached hemostasis after 10s in 100%, 42.8%, 7.1% and 14.3%, respectively, and at 3 min in 100%, 100%, 14.3% and 35.7%, respectively, on all liver and spleen punctures and resections.</p><p><strong>Conclusions: </strong>NHS-POx-based patches, and particularly the GATT-Patch, are fast in achieving effective hemostatic sealing on standardized moderate and severe bleedings without apparent long-term adverse events.</p>","PeriodicalId":48867,"journal":{"name":"World Journal of Emergency Surgery","volume":"18 1","pages":"19"},"PeriodicalIF":6.0000,"publicationDate":"2023-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10012589/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Emergency Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13017-023-00483-x","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: A new hemostatic sealant based on a N-hydroxy-succinimide polyoxazoline (NHS-POx) polymer was evaluated to determine hemostatic efficacy and long-term wound healing and adverse effects in a large animal model of parenchymal organ surgical bleeds.

Methods: Experiment 1 included 20 pigs that were treated with two NHS-POx patch prototypes [a gelatin fibrous carrier (GFC) with NHS-POx and an oxidized regenerated cellulose (ORC) with poly(lactic-co-glycolic acid)-NHS-POx:NU-POx (nucleophilically activated polyoxazoline)], a blank gelatin patch (GFC Blank), TachoSil® and Veriset™ to stop moderate liver and spleen punch bleedings. After various survival periods (1-6 weeks), pigs were re-operated to evaluate patch degradation and parenchymal healing. During the re-operation, experiment 2 was performed: partial liver and spleen resections with severe bleeding, and hemostatic efficacy was evaluated under normal and heparinized conditions of the two previous prototypes and one additional NHS-POx patch. In the third experiment an improved NHS-POx patch (GATT-Patch; GFC-NHS-POx and added 20% as nucleophilically activated polyoxazoline; NU-POx) was compared with TachoSil®, Veriset™ and GFC Blank on punch bleedings and partial liver and spleen resections for rapid (10s) hemostatic efficacy.

Results: NHS-POx-based patches showed better (GFC-NHS-POx 83.1%, ORC-PLGA-NHS-POx: NU-POx 98.3%) hemostatic efficacy compared to TachoSil® (25.0%) and GFC Blank (43.3%), and comparable efficacy with Veriset™ (96.7%) on moderate standardized punch bleedings on liver and spleen. All patches demonstrated gradual degradation over 6 weeks with a reduced local inflammation rate and an improved wound healing. For severe bleedings under non-heparinized conditions, hemostasis was achieved in 100% for Veriset™, 40% for TachoSil and 80-100% for the three NHS-POx prototypes; similar differences between patches remained for heparinized conditions. In experiment 3, GATT-Patch, Veriset™, TachoSil and GFC Blank reached hemostasis after 10s in 100%, 42.8%, 7.1% and 14.3%, respectively, and at 3 min in 100%, 100%, 14.3% and 35.7%, respectively, on all liver and spleen punctures and resections.

Conclusions: NHS-POx-based patches, and particularly the GATT-Patch, are fast in achieving effective hemostatic sealing on standardized moderate and severe bleedings without apparent long-term adverse events.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种新型聚恶唑啉类止血贴在肝脾手术中的疗效观察。
背景:在大型动物肝实质器官手术出血模型中,研究了一种基于n -羟基琥珀酰亚胺聚恶唑啉(NHS-POx)聚合物的新型止血密封剂的止血效果和长期伤口愈合及不良反应。方法:实验1包括20头猪,用两种NHS-POx贴片原型(明胶纤维载体(GFC)含有NHS-POx和氧化再生纤维素(ORC)含有聚(乳酸-羟基乙酸)-NHS-POx: nupox(亲核活性聚恶唑啉))、空白明胶贴片(GFC blank)、TachoSil®和Veriset™处理,以阻止中度肝脏和脾脏穿孔出血。在不同的生存期(1-6周)后,猪再次手术以评估贴片降解和实质愈合。再次手术时,进行实验2:切除部分肝脏和脾脏,严重出血,并在正常和肝素化条件下评估前2个原型和1个额外的NHS-POx贴片的止血效果。在第三个实验中,改进的NHS-POx patch (GATT-Patch;GFC-NHS-POx和添加20%为亲核活化聚恶唑啉;将NU-POx与TachoSil®、Veriset™和GFC Blank在穿孔出血和部分肝脾切除方面的快速(10s)止血效果进行比较。结果:与TachoSil®(25.0%)和GFC Blank(43.3%)相比,基于nhs - pox的贴片(GFC- nhs - pox 83.1%, ORC-PLGA-NHS-POx: nul - pox 98.3%)具有更好的止血效果,与Veriset™(96.7%)相比,对肝脏和脾脏中度标准化穿孔出血的疗效相当。所有贴片在6周内逐渐退化,局部炎症率降低,伤口愈合改善。对于非肝素化条件下的严重出血,Veriset™的止血率为100%,TachoSil的止血率为40%,三种NHS-POx原型的止血率为80-100%;在肝素化的情况下,斑块之间仍然存在类似的差异。在实验3中,gtat - patch、Veriset™、TachoSil和GFC Blank在所有肝脾穿刺和切除中,10s后分别100%、42.8%、7.1%和14.3%达到止血,3min后分别100%、100%、14.3%和35.7%达到止血。结论:基于nhs - pox的贴片,特别是GATT-Patch,在标准化的中重度出血中快速实现有效止血密封,且无明显的长期不良事件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
World Journal of Emergency Surgery
World Journal of Emergency Surgery EMERGENCY MEDICINE-SURGERY
CiteScore
14.50
自引率
5.00%
发文量
60
审稿时长
10 weeks
期刊介绍: The World Journal of Emergency Surgery is an open access, peer-reviewed journal covering all facets of clinical and basic research in traumatic and non-traumatic emergency surgery and related fields. Topics include emergency surgery, acute care surgery, trauma surgery, intensive care, trauma management, and resuscitation, among others.
期刊最新文献
Prophylactic PICO◊ dressing shortens wound dressing requirements post emergency laparotomy (EL-PICO◊ trial) A new technology for medical and surgical data organisation: the WSES-WJES Decentralised Knowledge Graph Erector spinae plane block (ESPB) enhances hemodynamic stability decreasing analgesic requirements in surgical stabilization of rib fractures (SSRFs) Ultra minimally invasive surgical stabilization of Rib fractures (uMI-SSRF): reduction and fixation techniques to minimize the surgical wound Ultrasonic dissection versus electrocautery dissection in laparoscopic cholecystectomy for acute cholecystitis: a randomized controlled trial (SONOCHOL-trial)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1