Osseointegration in relation to drilling speed in the preparation of dental implants sites: A systematic review

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthetic Dentistry Pub Date : 2025-02-01 DOI:10.1016/j.prosdent.2023.03.004
Cícero Andrade Sigilião Celles DDS , Izabela Ferreira DDS , Mariana da Lima da Costa Valente PhD , Andréa Cândido dos Reis PhD
{"title":"Osseointegration in relation to drilling speed in the preparation of dental implants sites: A systematic review","authors":"Cícero Andrade Sigilião Celles DDS ,&nbsp;Izabela Ferreira DDS ,&nbsp;Mariana da Lima da Costa Valente PhD ,&nbsp;Andréa Cândido dos Reis PhD","doi":"10.1016/j.prosdent.2023.03.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div>The drilling speed used for preparing dental implants<span> may affect bone-implant contact (BIC), implant stability quotient (ISQ), and bone area fraction occupancy (BAFO). Different rotational speeds and the presence or absence of irrigation during site preparation have been investigated, but an established protocol for achieving the best osseointegration results is lacking.</span></div></div><div><h3>Purpose</h3><div><span>The purpose of this systematic review was to investigate the influence of drill rotational speed on bone drilling for </span>dental implant placement and its relationship with osseointegration.</div></div><div><h3>Material and methods</h3><div>This review included the preferred reporting items for systematic reviews and meta-analyses (PRISMA) and was registered in the international prospective register of systematic reviews (PROSPERO) database. Electronic searches were performed in the MEDLINE (PubMed), Scopus, Science Direct, and Embase databases. The risk of bias was analyzed by using the systematic review center for laboratory animal experimentation (SYRCLE).</div></div><div><h3>Results</h3><div>A total of 1282 articles were found, and after removing duplicates and applying the eligibility criteria to in vivo articles on animals that addressed drilling speed and its relationship to osseointegration, 8 articles were selected for analysis. Of these, 5 articles showed no statistical differences, and 3 others showed significantly better osseointegration results by analyzing the parameters of BIC, BAFO, ISQs, and pull-out forces (PoFs). In all selected articles, high-speed drilling was performed with irrigation.</div></div><div><h3>Conclusions</h3><div>Although drilling speed seems to affect bone perforation, no definitive protocol was found in the literature consulted. The results vary depending on the combination of different factors, including bone type, irrigation, and drilling speed.</div></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"133 2","pages":"Pages 394-401"},"PeriodicalIF":4.3000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391323001385","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem

The drilling speed used for preparing dental implants may affect bone-implant contact (BIC), implant stability quotient (ISQ), and bone area fraction occupancy (BAFO). Different rotational speeds and the presence or absence of irrigation during site preparation have been investigated, but an established protocol for achieving the best osseointegration results is lacking.

Purpose

The purpose of this systematic review was to investigate the influence of drill rotational speed on bone drilling for dental implant placement and its relationship with osseointegration.

Material and methods

This review included the preferred reporting items for systematic reviews and meta-analyses (PRISMA) and was registered in the international prospective register of systematic reviews (PROSPERO) database. Electronic searches were performed in the MEDLINE (PubMed), Scopus, Science Direct, and Embase databases. The risk of bias was analyzed by using the systematic review center for laboratory animal experimentation (SYRCLE).

Results

A total of 1282 articles were found, and after removing duplicates and applying the eligibility criteria to in vivo articles on animals that addressed drilling speed and its relationship to osseointegration, 8 articles were selected for analysis. Of these, 5 articles showed no statistical differences, and 3 others showed significantly better osseointegration results by analyzing the parameters of BIC, BAFO, ISQs, and pull-out forces (PoFs). In all selected articles, high-speed drilling was performed with irrigation.

Conclusions

Although drilling speed seems to affect bone perforation, no definitive protocol was found in the literature consulted. The results vary depending on the combination of different factors, including bone type, irrigation, and drilling speed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
骨整合与牙种植体位置准备中钻孔速度的关系:一项系统综述。
问题陈述:用于制备牙种植体的钻孔速度可能会影响骨-种植体接触(BIC),种植体稳定商(ISQ)和骨面积分数占用(BAFO)。已经研究了不同的旋转速度和在场地准备过程中是否进行灌溉,但缺乏实现最佳骨整合结果的既定方案。目的:本系统综述的目的是探讨牙种植体植入中钻头转速对骨钻孔的影响及其与骨整合的关系。材料和方法:本综述纳入了系统评价和荟萃分析的首选报告项目(PRISMA),并在国际前瞻性系统评价注册(PROSPERO)数据库中注册。在MEDLINE (PubMed)、Scopus、Science Direct和Embase数据库中进行电子检索。通过实验动物实验系统评价中心(sycle)进行偏倚风险分析。结果:共找到1282篇文章,在去除重复并将合格标准应用于研究钻孔速度及其与骨整合关系的动物体内文章后,选择了8篇文章进行分析。其中,5篇文献无统计学差异,3篇文献通过分析BIC、BAFO、ISQs、拔牙力(pof)等参数显示骨整合效果明显改善。在所有选定的文章中,高速钻孔与灌溉一起进行。结论:虽然钻孔速度似乎影响骨穿孔,但在查阅的文献中没有找到明确的方案。结果取决于不同因素的组合,包括骨类型、灌溉和钻孔速度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
期刊最新文献
Accuracy of complete arch implant scans recorded by using intraoral and extraoral photogrammetry systems. A meta-analysis of the accuracy of different measuring techniques to evaluate the marginal and internal gap of a fixed dental prosthesis: The American Academy of Fixed Prosthodontics, Research in Fixed Prosthodontics Committee. Accuracy of registration between digitized extraoral scan bodies and virtual casts: Effect of the edentulous area, tooth anatomy, and registration method. An AI-based tool for prosthetic crown segmentation serving automated intraoral scan-to-CBCT registration in challenging high artifact scenarios. Comparison of scanning depth in widened root canals: An analysis of three intraoral scanners and two scanning techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1