Compact laser spectroscopic sensor head prototype for time-resolved breath oxygen monitoring.

IF 3.7 4区 医学 Q1 BIOCHEMICAL RESEARCH METHODS Journal of breath research Pub Date : 2023-01-30 DOI:10.1088/1752-7163/acb07a
Link Patrick, Gerard Wysocki
{"title":"Compact laser spectroscopic sensor head prototype for time-resolved breath oxygen monitoring.","authors":"Link Patrick,&nbsp;Gerard Wysocki","doi":"10.1088/1752-7163/acb07a","DOIUrl":null,"url":null,"abstract":"<p><p>A small and lightweight optical sensor head prototype with a disposable airway adapter for continuous mainstream monitoring of oxygen at high sampling rate is designed and tested on an optical benchtop. In terms of its size and functionality, the sensor head design is similar to current capnography systems from leading medical equipment manufacturers, and it has been designed within constraints of potential applications in direct breath oxygen monitoring that require direct interaction with the gas inside a breathing tube. The measurement precision of 0.1% O<sub>2</sub>with a 10 ms integration time are well within the performance required for breath O<sub>2</sub>monitoring applications.</p>","PeriodicalId":15306,"journal":{"name":"Journal of breath research","volume":"17 2","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2023-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of breath research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1088/1752-7163/acb07a","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

A small and lightweight optical sensor head prototype with a disposable airway adapter for continuous mainstream monitoring of oxygen at high sampling rate is designed and tested on an optical benchtop. In terms of its size and functionality, the sensor head design is similar to current capnography systems from leading medical equipment manufacturers, and it has been designed within constraints of potential applications in direct breath oxygen monitoring that require direct interaction with the gas inside a breathing tube. The measurement precision of 0.1% O2with a 10 ms integration time are well within the performance required for breath O2monitoring applications.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于时间分辨呼吸氧监测的紧凑型激光光谱传感器头部原型。
设计了一种小而轻的光学传感器头原型,该原型带有一次性气道适配器,用于在高采样率下连续主流监测氧气。就其尺寸和功能而言,传感器头部的设计类似于目前领先的医疗设备制造商的二氧化碳成像系统,并且它的设计限制了直接呼吸氧气监测的潜在应用,需要与呼吸管内的气体直接相互作用。测量精度为0.1% o2,集成时间为10 ms,完全符合呼吸o2监测应用所需的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of breath research
Journal of breath research BIOCHEMICAL RESEARCH METHODS-RESPIRATORY SYSTEM
CiteScore
7.60
自引率
21.10%
发文量
49
审稿时长
>12 weeks
期刊介绍: Journal of Breath Research is dedicated to all aspects of scientific breath research. The traditional focus is on analysis of volatile compounds and aerosols in exhaled breath for the investigation of exogenous exposures, metabolism, toxicology, health status and the diagnosis of disease and breath odours. The journal also welcomes other breath-related topics. Typical areas of interest include: Big laboratory instrumentation: describing new state-of-the-art analytical instrumentation capable of performing high-resolution discovery and targeted breath research; exploiting complex technologies drawn from other areas of biochemistry and genetics for breath research. Engineering solutions: developing new breath sampling technologies for condensate and aerosols, for chemical and optical sensors, for extraction and sample preparation methods, for automation and standardization, and for multiplex analyses to preserve the breath matrix and facilitating analytical throughput. Measure exhaled constituents (e.g. CO2, acetone, isoprene) as markers of human presence or mitigate such contaminants in enclosed environments. Human and animal in vivo studies: decoding the ''breath exposome'', implementing exposure and intervention studies, performing cross-sectional and case-control research, assaying immune and inflammatory response, and testing mammalian host response to infections and exogenous exposures to develop information directly applicable to systems biology. Studying inhalation toxicology; inhaled breath as a source of internal dose; resultant blood, breath and urinary biomarkers linked to inhalation pathway. Cellular and molecular level in vitro studies. Clinical, pharmacological and forensic applications. Mathematical, statistical and graphical data interpretation.
期刊最新文献
Correlations between Propofol Concentration in Exhaled Breath and BIS in Patients undergoing Thyroid Surgery. Halitosis in oral lichen planus patients. Validation of a sensor system for the measurement of breath ammonia using selected-ion flow-tube mass spectrometry. Therapeutic efficacy of a probiotic preparation on idiopathic halitosis: a retrospective observational study. Effectiveness of a combination of laccase and green coffee extract on oral malodor: A comparative, randomized, controlled, evaluator-blind, parallel-group trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1