Luís Guilherme Scavone de Macedo, André Antonio Pelegrine, Peter Karyen Moy
{"title":"Barbell Technique: A Novel Approach for Bidirectional Bone Augmentation: Clinical and Tomographic Study.","authors":"Luís Guilherme Scavone de Macedo, André Antonio Pelegrine, Peter Karyen Moy","doi":"10.1563/aaid-joi-D-21-00286","DOIUrl":null,"url":null,"abstract":"<p><p>Horizontal bone augmentation is a common surgical procedure used in implant therapy to achieve adequate bone volume to permit dental implant placement. However, most current techniques are focused on unidirectional bone reconstruction (grafting only on the buccal side). This study was carried out to validate a new device that will permit bidirectional bone augmentation. Ten patients of both sexes (7 women and 3 men), with ages ranging from 29 to 62 years, who needed a bidirectional horizontal bone augmentation in maxilla were separated in accordance with the horizontal alveolar change (HAC) classification published by Pelegrine et al (2018). The patients classified as HAC 3 (ie, containing remaining cancellous bone at the recipient bed) received the Barbell device with xenogeneic biomaterial and a collagen membrane, whereas HAC 4 patients (ie, with no remaining cancellous bone at the recipient bed) received the Barbell device with a mixture of autogenous bone chips and xenogeneic biomaterial covered by a collagen membrane. For each patient, two computerized tomography scans were performed (T0 at baseline and T1 at 6 months postoperative examinations). Mean bone thickness (T0) in the studied sites were 3.25 ± 0.35 in HAC 3 and 1.98 ± 0.5 in HAC 4 patients. The mean bone thickness achieved after 6 months was 7.70 ± 0.89 mm and 8.62 ± 0.89 in HAC 3 and 4, respectively. All grafted sites were able to receive dental implants in adequate prosthetic positions. Based on these results, the use of this novel device permits bidirectional horizontal bone augmentation.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":" ","pages":"458-464"},"PeriodicalIF":1.5000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Oral Implantology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-21-00286","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Horizontal bone augmentation is a common surgical procedure used in implant therapy to achieve adequate bone volume to permit dental implant placement. However, most current techniques are focused on unidirectional bone reconstruction (grafting only on the buccal side). This study was carried out to validate a new device that will permit bidirectional bone augmentation. Ten patients of both sexes (7 women and 3 men), with ages ranging from 29 to 62 years, who needed a bidirectional horizontal bone augmentation in maxilla were separated in accordance with the horizontal alveolar change (HAC) classification published by Pelegrine et al (2018). The patients classified as HAC 3 (ie, containing remaining cancellous bone at the recipient bed) received the Barbell device with xenogeneic biomaterial and a collagen membrane, whereas HAC 4 patients (ie, with no remaining cancellous bone at the recipient bed) received the Barbell device with a mixture of autogenous bone chips and xenogeneic biomaterial covered by a collagen membrane. For each patient, two computerized tomography scans were performed (T0 at baseline and T1 at 6 months postoperative examinations). Mean bone thickness (T0) in the studied sites were 3.25 ± 0.35 in HAC 3 and 1.98 ± 0.5 in HAC 4 patients. The mean bone thickness achieved after 6 months was 7.70 ± 0.89 mm and 8.62 ± 0.89 in HAC 3 and 4, respectively. All grafted sites were able to receive dental implants in adequate prosthetic positions. Based on these results, the use of this novel device permits bidirectional horizontal bone augmentation.
期刊介绍:
The official publication of the American Academy of Implant Dentistry and of the American Academy of Implant Prosthodontics, is dedicated to providing valuable information to general dentists, oral surgeons, prosthodontists, periodontists, scientists, clinicians, laboratory owners and technicians, manufacturers, and educators. Implant basics, prosthetics, pharmaceuticals, the latest research in implantology, implant surgery, and advanced implant procedures are just some of the topics covered.