Monitoring Spike Potential and Abrupt Impedance Rise with Concomitant Temperature/Contact Force Change for Timely Detection of the Occurrence of "Silent" or "Nonaudible" Steam Pop.

IF 1.6 3区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of interventional cardiology Pub Date : 2023-04-05 eCollection Date: 2023-01-01 DOI:10.1155/2023/8873404
Chengye Di, Qun Wang, Yanxi Wu, Longyu Li, Wenhua Lin
{"title":"Monitoring Spike Potential and Abrupt Impedance Rise with Concomitant Temperature/Contact Force Change for Timely Detection of the Occurrence of \"Silent\" or \"Nonaudible\" Steam Pop.","authors":"Chengye Di, Qun Wang, Yanxi Wu, Longyu Li, Wenhua Lin","doi":"10.1155/2023/8873404","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>Steam pop (SP) during radiofrequency catheter ablation (RFCA) for pulmonary vein isolation (PVI) may cause cardiac perforation, which may require drainage and emergent thoracotomy or even lead to death. Data investigating the timely detection of the occurrence of \"silent\" or \"nonaudible\" SP events are limited.</p><p><strong>Methods and results: </strong>A total of 516 consecutive atrial fibrillation (AF) patients who underwent index PVI were included in this retrospective observational study. The duration, power, impedance, temperature, and contact force (CF) of RFCA were continually monitored and recorded throughout the procedure. A total of 15 (2.9%) audible SP events occurred in 14 patients; 2 of the patients developed pericardial tamponade, 1 patient underwent drainage, and 1 patient underwent emergent thoracotomy. The time from RFCA initiation to the occurrence of audible SP was 19.4 ± 6.9 s. Abrupt temperature change occurred in 13 (86.7%) of the 15 SP events, of which 8 (53.3%) exhibited an abrupt temperature rise of 2.3 ± 1.0°C, 5 (33.3%) exhibited an abrupt temperature drop of 2.3 ± 1.3°C, and 2 (13.3%) exhibited no discernible temperature change.</p><p><strong>Conclusions: </strong>In conclusion, simultaneously recorded spike potentials and abrupt impedance rise with concomitant temperature and/or CF change could be a feasible method for the timely detection of the occurrence of audible, \"silent,\" or \"nonaudible\" SP events, particularly in regions where the risk of perforation may be of concern.</p>","PeriodicalId":16329,"journal":{"name":"Journal of interventional cardiology","volume":"2023 ","pages":"8873404"},"PeriodicalIF":1.6000,"publicationDate":"2023-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10098411/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of interventional cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/2023/8873404","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: Steam pop (SP) during radiofrequency catheter ablation (RFCA) for pulmonary vein isolation (PVI) may cause cardiac perforation, which may require drainage and emergent thoracotomy or even lead to death. Data investigating the timely detection of the occurrence of "silent" or "nonaudible" SP events are limited.

Methods and results: A total of 516 consecutive atrial fibrillation (AF) patients who underwent index PVI were included in this retrospective observational study. The duration, power, impedance, temperature, and contact force (CF) of RFCA were continually monitored and recorded throughout the procedure. A total of 15 (2.9%) audible SP events occurred in 14 patients; 2 of the patients developed pericardial tamponade, 1 patient underwent drainage, and 1 patient underwent emergent thoracotomy. The time from RFCA initiation to the occurrence of audible SP was 19.4 ± 6.9 s. Abrupt temperature change occurred in 13 (86.7%) of the 15 SP events, of which 8 (53.3%) exhibited an abrupt temperature rise of 2.3 ± 1.0°C, 5 (33.3%) exhibited an abrupt temperature drop of 2.3 ± 1.3°C, and 2 (13.3%) exhibited no discernible temperature change.

Conclusions: In conclusion, simultaneously recorded spike potentials and abrupt impedance rise with concomitant temperature and/or CF change could be a feasible method for the timely detection of the occurrence of audible, "silent," or "nonaudible" SP events, particularly in regions where the risk of perforation may be of concern.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
监测尖峰电位和阻抗骤然升高以及伴随的温度/接触力变化,及时发现 "无声 "或 "听不见 "的蒸汽爆裂。
目的:肺静脉隔离术(PVI)射频导管消融(RFCA)过程中的蒸汽爆裂(SP)可能会导致心脏穿孔,可能需要引流和紧急开胸手术,甚至导致死亡。及时发现 "无声 "或 "听不见 "SP事件的研究数据非常有限:这项回顾性观察研究共纳入了 516 名连续接受指数 PVI 的心房颤动(房颤)患者。在整个手术过程中持续监测和记录了 RFCA 的持续时间、功率、阻抗、温度和接触力 (CF)。14 名患者共发生了 15 次(2.9%)可闻及的 SP 事件;其中 2 名患者出现心包填塞,1 名患者进行了引流,1 名患者进行了紧急开胸手术。从开始实施 RFCA 到发生可闻 SP 的时间为 19.4±6.9 秒。15 个 SP 事件中有 13 个(86.7%)发生了温度骤变,其中 8 个(53.3%)显示温度骤升 2.3 ± 1.0°C,5 个(33.3%)显示温度骤降 2.3 ± 1.3°C,2 个(13.3%)显示温度无明显变化:总之,同时记录尖峰电位和阻抗骤然升高,并伴随温度和/或 CF 变化,是及时发现可闻、"无声 "或 "不可闻 "SP 事件的可行方法,尤其是在可能存在穿孔风险的地区。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of interventional cardiology
Journal of interventional cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.80
自引率
0.00%
发文量
81
审稿时长
6-12 weeks
期刊介绍: Journal of Interventional Cardiology is a peer-reviewed, Open Access journal that provides a forum for cardiologists determined to stay current in the diagnosis, investigation, and management of patients with cardiovascular disease and its associated complications. The journal publishes original research articles, review articles, and clinical studies focusing on new procedures and techniques in all major subject areas in the field, including: Acute coronary syndrome Coronary disease Congenital heart diseases Myocardial infarction Peripheral arterial disease Valvular heart disease Cardiac hemodynamics and physiology Haemostasis and thrombosis
期刊最新文献
Epidemiological Trends, Etiology, and Burden Study of Heart Failure in China, 1990–2019 A Comparative Analysis of Primary and Bailout ADR in CTO-PCI The Effect of Electromagnetic Interference Produced by Smartphones Using 5G Network on Patients With Permanent Pacemakers (EMS5G-PPM Study) Comparison of Sheathless and Sheathed Guiding Catheters in Transradial Percutaneous Coronary Interventions: A Systematic Review and Meta-Analysis Percutaneous Coronary Intervention Using the DynamX Sirolimus-Eluting Bioadaptor: 12-Month Clinical and Imaging Outcomes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1