{"title":"Comparing Original and Universal Screwdrivers and How They Affect Friction in the Screw.","authors":"Vasilios Alevizakos, Nadine Achilles, Björn Rahlf, Philipp Jehn, Constantin von See, Marcus Schiller","doi":"10.1563/aaid-joi-D-20-00249","DOIUrl":null,"url":null,"abstract":"<p><p>The present study focused on investigating whether universal screwdriver kits cause less friction between the screwdriver and the abutment screw than original screwdrivers. For this purpose, 2 original screwdrivers (Straumann and BEGO) and a universal screwdriver kit (bredent) were investigated. On 1 implant per screwdriver, 26 abutments were properly attached one after the other with the corresponding abutment screws. After tightening the abutment screw, the force required to pull the screwdriver off the screw head was determined with a spring balance. For both manufacturers, greater pull-off forces were measured when using the original screwdrivers than when using the universal screwdriver. The pull-off force (mean ± SD) required for the Straumann original screwdriver was 3.7 ± 1.4 N, while that required for the universal screwdriver was 0.1 ± 0.1 N (P < .001). The pull-off force was 1.5 ± 1.5 N for the BEGO original screwdriver and 0.7 ± 0.9 N for the universal screwdriver (P = .19). Using original manufacturer-supplied screwdrivers could thus minimize the risk of the screwdriver slipping out of the screw head during dental treatment and being swallowed or aspirated by the patient.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":" ","pages":"532-536"},"PeriodicalIF":1.5000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Oral Implantology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-20-00249","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
The present study focused on investigating whether universal screwdriver kits cause less friction between the screwdriver and the abutment screw than original screwdrivers. For this purpose, 2 original screwdrivers (Straumann and BEGO) and a universal screwdriver kit (bredent) were investigated. On 1 implant per screwdriver, 26 abutments were properly attached one after the other with the corresponding abutment screws. After tightening the abutment screw, the force required to pull the screwdriver off the screw head was determined with a spring balance. For both manufacturers, greater pull-off forces were measured when using the original screwdrivers than when using the universal screwdriver. The pull-off force (mean ± SD) required for the Straumann original screwdriver was 3.7 ± 1.4 N, while that required for the universal screwdriver was 0.1 ± 0.1 N (P < .001). The pull-off force was 1.5 ± 1.5 N for the BEGO original screwdriver and 0.7 ± 0.9 N for the universal screwdriver (P = .19). Using original manufacturer-supplied screwdrivers could thus minimize the risk of the screwdriver slipping out of the screw head during dental treatment and being swallowed or aspirated by the patient.
期刊介绍:
The official publication of the American Academy of Implant Dentistry and of the American Academy of Implant Prosthodontics, is dedicated to providing valuable information to general dentists, oral surgeons, prosthodontists, periodontists, scientists, clinicians, laboratory owners and technicians, manufacturers, and educators. Implant basics, prosthetics, pharmaceuticals, the latest research in implantology, implant surgery, and advanced implant procedures are just some of the topics covered.