Statistical considerations for testing automated sphygmomanometers in special patient populations.

IF 1.2 4区 医学 Q4 PERIPHERAL VASCULAR DISEASE Blood Pressure Monitoring Pub Date : 2023-06-01 DOI:10.1097/MBP.0000000000000644
Bruce S Alpert, Paul Matsumura, Colin O Wu, Bruce Friedman, Doris Flotzinger, David Osborn
{"title":"Statistical considerations for testing automated sphygmomanometers in special patient populations.","authors":"Bruce S Alpert,&nbsp;Paul Matsumura,&nbsp;Colin O Wu,&nbsp;Bruce Friedman,&nbsp;Doris Flotzinger,&nbsp;David Osborn","doi":"10.1097/MBP.0000000000000644","DOIUrl":null,"url":null,"abstract":"<p><p>The International Standards Organization 81060-2:2018 is the current global Standard for the validation of automated sphygmomanometers. It specifies the requirements for clinical studies on the general population, as well as additional requirements for special populations, which might have physiologic characteristics that affect the accuracy of blood pressure measurements. This paper summarizes the statistical methodology behind the sample size required to test automated sphygmomanometers in these special populations and specifically addresses the pregnant patient population.</p>","PeriodicalId":8950,"journal":{"name":"Blood Pressure Monitoring","volume":"28 3","pages":"167-170"},"PeriodicalIF":1.2000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Pressure Monitoring","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBP.0000000000000644","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

The International Standards Organization 81060-2:2018 is the current global Standard for the validation of automated sphygmomanometers. It specifies the requirements for clinical studies on the general population, as well as additional requirements for special populations, which might have physiologic characteristics that affect the accuracy of blood pressure measurements. This paper summarizes the statistical methodology behind the sample size required to test automated sphygmomanometers in these special populations and specifically addresses the pregnant patient population.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在特殊患者群体中测试自动血压计的统计考虑。
国际标准组织81060-2:2018是目前自动血压计验证的全球标准。它规定了对一般人群进行临床研究的要求,以及对特殊人群的额外要求,这些人群可能具有影响血压测量准确性的生理特征。本文总结了在这些特殊人群中测试自动血压计所需样本量的统计方法,并特别针对怀孕患者群体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Blood Pressure Monitoring
Blood Pressure Monitoring 医学-外周血管病
CiteScore
2.00
自引率
7.70%
发文量
110
审稿时长
>12 weeks
期刊介绍: Blood Pressure Monitoring is devoted to original research in blood pressure measurement and blood pressure variability. It includes device technology, analytical methodology of blood pressure over time and its variability, clinical trials - including, but not limited to, pharmacology - involving blood pressure monitoring, blood pressure reactivity, patient evaluation, and outcomes and effectiveness research. This innovative journal contains papers dealing with all aspects of manual, automated, and ambulatory monitoring. Basic and clinical science papers are considered although the emphasis is on clinical medicine. Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool.
期刊最新文献
Validation of the automated oscillometric upper-arm cuff home blood pressure monitor Microlife BP3KV1-5X (BP B6 Connect) in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard (ISO 81060-2:2018). Association between the direction of the blood pressure discrepancy and vascular aging in a large-scale screening population. Validation of the automated oscillometric upper-arm cuff home blood pressure monitor Microlife BP3KT1-4X (BP B3 Comfort PC) in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard (ISO 81060-2:2018). Combination of treatment intensity score and interankle diastolic blood pressure is associated with cardiovascular prognosis among adults with controlled hypertension who have pre-existing cardiovascular disease. Validation of the BTL ambulatory blood pressure monitoring NG ambulatory blood pressure monitoring device according to the Universal Standard International Organization for Standardization 81060-2:2018.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1