{"title":"Variations and effects of bladder and rectal volume following uniform preparation procedure in cervical cancer: Five fractions of 6 Gy.","authors":"Bin-Qiang Ye, Cheng-Zong Zhao, Peng-Fei Sun","doi":"10.5114/jcb.2023.126863","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To analyze the effects of different bladder and rectal volumes on the dose of organ at risks (OARs) and primary tumors following uniform preparation procedure.</p><p><strong>Material and methods: </strong>In this retrospective study, a total of 60 patients with cervical cancer treated with external beam radiation therapy (EBRT) combined with chemotherapy and brachytherapy (BT) during 2019-2022 were included (300 insertions). Then, tandem-ovoid applicators were placed and computed tomography (CT) scanning was performed after each insertion. Delineation of OARs and clinical target volumes (CTVs) were done according to GEC-ESTRO group recommendations. Finally, doses of high-risk clinical target volume (HR-CTV) and OARs were obtained from dose volume histogram (DVH) automatically generated by BT treatment planning system.</p><p><strong>Results: </strong>Following a uniform preparation procedure, the median bladder volume of 68.36 cc (range, 29.9-235.68 cc) was in optimal agreement with the recommended bladder volume of ≤ 70 ml, which avoided more manipulation and possible risk of adverse events during general anesthesia. As the bladder filling volume increased, there was no corresponding increase in rectal, HR-CTV, and small bowel volumes, while the sigmoid colon volume decreased. The median rectal volume was 54.95 cc (range, 24.92-168.1 cc), and as the rectal volume increased, HR-CTV, sigmoid colon, and rectum volumes increased, and conversely, small bowel volume decreased. HR-CTV changes with volume affected the rectum, bladder, and HR-CTV, but not the sigmoid colon and small intestine.</p><p><strong>Conclusions: </strong>Following a uniform preparation procedure, the bladder and rectum can also be controlled to an optimal volume (B ≤ 70 cc, R ≈ 40 cc), which is related to the dose of the bladder, rectum, and sigmoid colon.</p>","PeriodicalId":51305,"journal":{"name":"Journal of Contemporary Brachytherapy","volume":"15 2","pages":"123-129"},"PeriodicalIF":1.1000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/bf/c1/JCB-15-50581.PMC10196726.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Brachytherapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5114/jcb.2023.126863","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To analyze the effects of different bladder and rectal volumes on the dose of organ at risks (OARs) and primary tumors following uniform preparation procedure.
Material and methods: In this retrospective study, a total of 60 patients with cervical cancer treated with external beam radiation therapy (EBRT) combined with chemotherapy and brachytherapy (BT) during 2019-2022 were included (300 insertions). Then, tandem-ovoid applicators were placed and computed tomography (CT) scanning was performed after each insertion. Delineation of OARs and clinical target volumes (CTVs) were done according to GEC-ESTRO group recommendations. Finally, doses of high-risk clinical target volume (HR-CTV) and OARs were obtained from dose volume histogram (DVH) automatically generated by BT treatment planning system.
Results: Following a uniform preparation procedure, the median bladder volume of 68.36 cc (range, 29.9-235.68 cc) was in optimal agreement with the recommended bladder volume of ≤ 70 ml, which avoided more manipulation and possible risk of adverse events during general anesthesia. As the bladder filling volume increased, there was no corresponding increase in rectal, HR-CTV, and small bowel volumes, while the sigmoid colon volume decreased. The median rectal volume was 54.95 cc (range, 24.92-168.1 cc), and as the rectal volume increased, HR-CTV, sigmoid colon, and rectum volumes increased, and conversely, small bowel volume decreased. HR-CTV changes with volume affected the rectum, bladder, and HR-CTV, but not the sigmoid colon and small intestine.
Conclusions: Following a uniform preparation procedure, the bladder and rectum can also be controlled to an optimal volume (B ≤ 70 cc, R ≈ 40 cc), which is related to the dose of the bladder, rectum, and sigmoid colon.
期刊介绍:
The “Journal of Contemporary Brachytherapy” is an international and multidisciplinary journal that will publish papers of original research as well as reviews of articles. Main subjects of the journal include: clinical brachytherapy, combined modality treatment, advances in radiobiology, hyperthermia and tumour biology, as well as physical aspects relevant to brachytherapy, particularly in the field of imaging, dosimetry and radiation therapy planning. Original contributions will include experimental studies of combined modality treatment, tumor sensitization and normal tissue protection, molecular radiation biology, and clinical investigations of cancer treatment in brachytherapy. Another field of interest will be the educational part of the journal.