DIAGNOdent versus International Caries Detection and Assessment System in detection of incipient carious lesions: A diagnostic accuracy study.

Q2 Dentistry Journal of Conservative Dentistry Pub Date : 2023-03-01 Epub Date: 2023-03-16 DOI:10.4103/jcd.jcd_575_22
Omar Osama Shaalan
{"title":"DIAGNOdent versus International Caries Detection and Assessment System in detection of incipient carious lesions: A diagnostic accuracy study.","authors":"Omar Osama Shaalan","doi":"10.4103/jcd.jcd_575_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The present investigation aimed at assessing the diagnostic accuracy of DIAGNOdent compared to the International Caries Detection and Assessment System-II (ICDAS-II) in the detection of facial, smooth surface noncavitated carious lesions.</p><p><strong>Settings and design: </strong>Sixty patients were enrolled in the current study according to the eligibility criteria. There were 161 teeth with noncavitated, white spot carious lesions and 32 sound teeth.</p><p><strong>Materials and methods: </strong>Before examination, teeth were cleaned and polished and all patients were assessed under standardized operating conditions: preset dental unit position, operating light, and prolonged air drying (approximately 5 s). All teeth were assessed by two calibrated examiners individually without any contact using ICDAS-II and DIAGNOdent.</p><p><strong>Statistical analysis: </strong>The diagnostic accuracy of DIAGNOdent device was determined, including sensitivity, specificity, overall accuracy, positive and negative predictive values, and receiver operating characteristic curve analysis. Chi-square test was conducted to compare the distribution of ICDAS-II and DIAGNOdent scores. Inter-observer agreement between assessors was evaluated using Cohen's kappa test.</p><p><strong>Results: </strong>In the current study, DIAGNOdent had an overall accuracy of 84.45% with sensitivity and specificity of 87.58% and 96.87%, respectively, and +PV and -PV of 97.7% and 83.9%, respectively, when score 0 represented sound tooth surface, while scores 1 and 2 were considered clinically noncavitated carious lesions. Moreover, when only ICDAS score 1 was considered representing first visual change in enamel, DIAGNOdent had an accuracy of 74.15% with sensitivity and specificity of 83.53% and 90.62%, respectively, and +PV and -PV of 93% and 78.6%, respectively. In the present study, when only ICDAS score 2 was considered representing distinct visual change in enamel, DIAGNOdent had an accuracy of 100% with sensitivity and specificity of 100% and 100%, respectively, and +PV and -PV of 100% and 100%, respectively.</p><p><strong>Conclusions: </strong>The overall performance of DIAGNOdent was equivalent to the visual inspection using ICDAS-II. DIAGNOdent might be considered a useful adjunctive device for detection and monitoring development of noncavitated carious lesions on facial smooth surfaces.</p>","PeriodicalId":38892,"journal":{"name":"Journal of Conservative Dentistry","volume":"26 2","pages":"199-206"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10190091/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Conservative Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jcd.jcd_575_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/16 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 1

Abstract

Aim: The present investigation aimed at assessing the diagnostic accuracy of DIAGNOdent compared to the International Caries Detection and Assessment System-II (ICDAS-II) in the detection of facial, smooth surface noncavitated carious lesions.

Settings and design: Sixty patients were enrolled in the current study according to the eligibility criteria. There were 161 teeth with noncavitated, white spot carious lesions and 32 sound teeth.

Materials and methods: Before examination, teeth were cleaned and polished and all patients were assessed under standardized operating conditions: preset dental unit position, operating light, and prolonged air drying (approximately 5 s). All teeth were assessed by two calibrated examiners individually without any contact using ICDAS-II and DIAGNOdent.

Statistical analysis: The diagnostic accuracy of DIAGNOdent device was determined, including sensitivity, specificity, overall accuracy, positive and negative predictive values, and receiver operating characteristic curve analysis. Chi-square test was conducted to compare the distribution of ICDAS-II and DIAGNOdent scores. Inter-observer agreement between assessors was evaluated using Cohen's kappa test.

Results: In the current study, DIAGNOdent had an overall accuracy of 84.45% with sensitivity and specificity of 87.58% and 96.87%, respectively, and +PV and -PV of 97.7% and 83.9%, respectively, when score 0 represented sound tooth surface, while scores 1 and 2 were considered clinically noncavitated carious lesions. Moreover, when only ICDAS score 1 was considered representing first visual change in enamel, DIAGNOdent had an accuracy of 74.15% with sensitivity and specificity of 83.53% and 90.62%, respectively, and +PV and -PV of 93% and 78.6%, respectively. In the present study, when only ICDAS score 2 was considered representing distinct visual change in enamel, DIAGNOdent had an accuracy of 100% with sensitivity and specificity of 100% and 100%, respectively, and +PV and -PV of 100% and 100%, respectively.

Conclusions: The overall performance of DIAGNOdent was equivalent to the visual inspection using ICDAS-II. DIAGNOdent might be considered a useful adjunctive device for detection and monitoring development of noncavitated carious lesions on facial smooth surfaces.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
DIAGNOdent与国际龋齿检测和评估系统在早期龋齿病变检测中的对比:诊断准确性研究。
目的:本研究旨在评估DIAGNOdent与国际龋齿检测和评估系统II(ICDAS-II)在检测面部光滑表面无空洞龋齿病变方面的诊断准确性。设置和设计:根据资格标准,60名患者被纳入本研究。161颗牙齿有无空洞、白斑龋坏,32颗牙齿完好。材料和方法:检查前,对所有患者进行牙齿清洁和抛光,并在标准化的操作条件下进行评估:预设牙科单元位置、手术灯和延长空气干燥时间(约5 s)。使用ICDAS-II和DIAGNOdent,由两名校准的检查人员在没有任何接触的情况下单独评估所有牙齿。统计分析:确定DIAGNOdant设备的诊断准确性,包括敏感性、特异性、总体准确性、阳性和阴性预测值,以及受试者操作特征曲线分析。卡方检验用于比较ICDAS-II和DIAGNOdent评分的分布。使用Cohen’s kappa检验评估评估员之间的观察者间一致性。结果:在目前的研究中,当0分代表健全的牙齿表面时,DIAGNOdent的总体准确率为84.45%,敏感性和特异性分别为87.58%和96.87%,+PV和-PV分别为97.7%和83.9%,而1分和2分被认为是临床上的非龋齿病变。此外,当仅ICDAS评分1被认为代表牙釉质的首次视觉变化时,DIAGNOdent的准确率为74.15%,敏感性和特异性分别为83.53%和90.62%,+PV和-PV分别为93%和78.6%。在本研究中,当仅ICDAS评分2被认为代表牙釉质的明显视觉变化时,DIAGNOdent的准确率为100%,敏感性和特异性分别为100%和100%,+PV和-PV分别为100%。结论:DIAGNOdent的整体性能相当于ICDAS-II的目视检查。DIAGNOdent可能被认为是一种有用的辅助设备,用于检测和监测面部光滑表面上非空洞性龋齿病变的发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Conservative Dentistry
Journal of Conservative Dentistry Dentistry-Dentistry (all)
CiteScore
2.10
自引率
0.00%
发文量
114
期刊介绍: The Journal of Conservative Dentistry (ISSN - 0972-0707) is the official journal of the Indian Association of Conservative Dentistry and Endodontics (IACDE). Our journal publishes scientific articles, case reports, short communications, invited reviews and comparative studies evaluating materials and methods in the fields of Conservative Dentistry, Dental Materials and Endodontics. J Conserv Dent has a diverse readership that includes full-time clinicians, full-time academicians, residents, students and scientists. Effective communication with this diverse readership requires careful attention to writing style.
期刊最新文献
The Effect of Adding Epigallocatechin-3-gallate on the Porosity of Calcium Hydroxide Determination of gamma radiation sterilization dose on bioceramic BCP-Sr-Ag as bone graft according to ISO 11137 standards Compressive strength of nanohybrid composite resin after the application of glycerin immersed in fermented milk Differences in the solubility of CaCO3 from blood clam shells and Ca(OH)2 as a candidate pulp capping material Effective Dose of Nano Propolis as Anti-Pain in Animal Models of Mus Musculus Using Writhing Test Method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1