Synchronisation of wearable inertial measurement units based on magnetometer data.

IF 1.8 4区 医学 Q4 ENGINEERING, BIOMEDICAL Biomedical Engineering / Biomedizinische Technik Pub Date : 2023-06-27 DOI:10.1515/bmt-2021-0329
Andreas Spilz, Michael Munz
{"title":"Synchronisation of wearable inertial measurement units based on magnetometer data.","authors":"Andreas Spilz,&nbsp;Michael Munz","doi":"10.1515/bmt-2021-0329","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Synchronisation of wireless inertial measurement units in human movement analysis is often achieved using event-based synchronisation techniques. However, these techniques lack precise event generation and accuracy. An inaccurate synchronisation could lead to large errors in motion estimation and reconstruction and therefore wrong analysis outputs.</p><p><strong>Methods: </strong>We propose a novel event-based synchronisation technique based on a magnetic field, which allows sub-sample accuracy. A setup featuring Shimmer3 inertial measurement units is designed to test the approach.</p><p><strong>Results: </strong>The proposed technique shows to be able to synchronise with a maximum offset of below 2.6 ms with sensors measuring at 100 Hz. The investigated parameters suggest a required synchronisation time of 8 s.</p><p><strong>Conclusions: </strong>The results indicate a reliable event generation and detection for synchronisation of wireless inertial measurement units. Further research should investigate the temperature changes that the sensors are exposed to during human motion analysis and their influence on the internal time measurement of the sensors. In addition, the approach should be tested using inertial measurement units from different manufacturers to investigate an identified constant offset in the accuracy measurements.</p>","PeriodicalId":8900,"journal":{"name":"Biomedical Engineering / Biomedizinische Technik","volume":"68 3","pages":"263-273"},"PeriodicalIF":1.8000,"publicationDate":"2023-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Engineering / Biomedizinische Technik","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1515/bmt-2021-0329","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Synchronisation of wireless inertial measurement units in human movement analysis is often achieved using event-based synchronisation techniques. However, these techniques lack precise event generation and accuracy. An inaccurate synchronisation could lead to large errors in motion estimation and reconstruction and therefore wrong analysis outputs.

Methods: We propose a novel event-based synchronisation technique based on a magnetic field, which allows sub-sample accuracy. A setup featuring Shimmer3 inertial measurement units is designed to test the approach.

Results: The proposed technique shows to be able to synchronise with a maximum offset of below 2.6 ms with sensors measuring at 100 Hz. The investigated parameters suggest a required synchronisation time of 8 s.

Conclusions: The results indicate a reliable event generation and detection for synchronisation of wireless inertial measurement units. Further research should investigate the temperature changes that the sensors are exposed to during human motion analysis and their influence on the internal time measurement of the sensors. In addition, the approach should be tested using inertial measurement units from different manufacturers to investigate an identified constant offset in the accuracy measurements.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于磁强计数据的可穿戴惯性测量装置同步。
目的:在人体运动分析中,无线惯性测量单元的同步通常使用基于事件的同步技术来实现。然而,这些技术缺乏精确的事件生成和准确性。不准确的同步可能导致运动估计和重建中的大误差,从而导致错误的分析输出。方法:我们提出了一种基于磁场的新的基于事件的同步技术,该技术允许子样本精度。设计了一个具有Shimmer3惯性测量单元的装置来测试该方法。结果:所提出的技术表明,能够与传感器在100 Hz测量的最大偏移量低于2.6 ms同步。所调查的参数表明所需的同步时间为8秒。结论:结果表明,无线惯性测量单元的同步可靠的事件产生和检测。进一步的研究应探讨传感器在人体运动分析过程中所暴露的温度变化及其对传感器内部时间测量的影响。此外,该方法应使用来自不同制造商的惯性测量单元进行测试,以研究精度测量中确定的常数偏移。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
5.90%
发文量
58
审稿时长
2-3 weeks
期刊介绍: Biomedical Engineering / Biomedizinische Technik (BMT) is a high-quality forum for the exchange of knowledge in the fields of biomedical engineering, medical information technology and biotechnology/bioengineering. As an established journal with a tradition of more than 60 years, BMT addresses engineers, natural scientists, and clinicians working in research, industry, or clinical practice.
期刊最新文献
Evaluation of the RF depositions at 3T in routine clinical scans with respect to the SAR safety to improve efficiency of MRI utilization Comparative evaluation of volumetry estimation from plain and contrast enhanced computed tomography liver images Sparse-view CT reconstruction based on group-based sparse representation using weighted guided image filtering Actuators and transmission mechanisms in rehabilitation lower limb exoskeletons: a review Abstracts of the 2023 Annual Meeting of the Austrian Society for Biomedical Engineering (ÖGBMT)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1