Developing the foundation for assessment of Devices used for Acute Ischemic Stroke Interventions (DAISI) using a Coordinated Registry Network.

Hartley LeRoy, Laura Elisabeth Gressler, David S Liebeskind, Claudette E Brooks, Adnan Siddiqui, Sameer Ansari, Murray Sheldon, Carlos Pena, Art Sedrakyan, Danica Marinac-Dabic
{"title":"Developing the foundation for assessment of Devices used for Acute Ischemic Stroke Interventions (DAISI) using a Coordinated Registry Network.","authors":"Hartley LeRoy, Laura Elisabeth Gressler, David S Liebeskind, Claudette E Brooks, Adnan Siddiqui, Sameer Ansari, Murray Sheldon, Carlos Pena, Art Sedrakyan, Danica Marinac-Dabic","doi":"10.1136/bmjsit-2021-000113","DOIUrl":null,"url":null,"abstract":"© Author(s) (or their employer(s)) 2022. Reuse permitted under CC BYNC. No commercial reuse. See rights and permissions. Published by BMJ. INTRODUCTION Stroke is the leading cause of disability with treatment costs exceeding $46 billion between 2014 and 2015 in the USA alone. 2 Every year, approximately 795 000 Americans suffer a new or recurrent stroke resulting in nearly 140 000 deaths, with 87% being ischemic strokes. Deviceassisted interventions, such as endovascular mechanical thrombectomy, can be used for the emergent treatment of acute ischemic stroke. The comprehensive assessment of safety and effectiveness of deviceassisted treatments is complicated by several factors, including complex and unique neurovascular anatomy, the timing of stroke presentations, and variable tissue tolerability to ischemia. Realworld data (RWD) collected during routine medical care of patients presenting with acute ischemic stroke may be used to develop realworld evidence (RWE) to help evaluate the safety and effectiveness of deviceassisted treatments. The generated RWE may support postmarket surveillance requirements, identify potential adverse events, and perhaps guide regulatory decisions. For these reasons, the Center for Devices and Radiological Health (CDRH) at the Food and Drug Administration (FDA) recognizes the potential value of RWE and its use in the course of clinical and regulatory decisionmaking when appropriate. Coordinated Registry Networks (CRNs) allow for the systematic aggregation of highquality RWD which can in turn be analyzed, potentially leading to relevant and reliable evidence for the evaluation of medical devices. 5 Prompted by participation in two public meetings in late 2015, FDA Public Meeting on Acute Ischemic Stroke and the Stroke Treatment Academic Industry Roundtable, the FDA began to consider initiating a registry to advance acute ischemic stroke clinical trials and, where appropriate, to capture data necessary to support regulatory, reimbursement, coverage, and physician decisionmaking. On February 2, 2017, the FDA held a Public Workshop on a CRN for Devices used for Acute Ischemic Stroke Interventions (DAISICRN). The purpose for this workshop was to obtain initial public stakeholders’ input and plan for future collaboration. On November 9, 2017, a multistakeholder group convened to launch the DAISI initiative. The mission of the DAISI initiative is to establish a CRN using RWE generated in the clinical care domain by patients, physicians, providers, and payers, for the purposes of enhancing regulatory and clinical decisionmaking, improving healthcare, and supporting the development of innovative devices to treat acute ischemic stroke. This CRN will use national and international databases to capture information from patient encounters with medical devices used to treat acute ischemic stroke using common data elements (CDEs) related to patient characteristics, medical history, the procedure, preoperative and postoperative imaging, treatment devices, technical outcomes, and clinical followup needed in the CRN for the assessment of successful revascularization using endovascular mechanical thrombectomy devices.","PeriodicalId":33349,"journal":{"name":"BMJ Surgery Interventions Health Technologies","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/7e/3d/bmjsit-2021-000113.PMC9660605.pdf","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Surgery Interventions Health Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjsit-2021-000113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 3

Abstract

© Author(s) (or their employer(s)) 2022. Reuse permitted under CC BYNC. No commercial reuse. See rights and permissions. Published by BMJ. INTRODUCTION Stroke is the leading cause of disability with treatment costs exceeding $46 billion between 2014 and 2015 in the USA alone. 2 Every year, approximately 795 000 Americans suffer a new or recurrent stroke resulting in nearly 140 000 deaths, with 87% being ischemic strokes. Deviceassisted interventions, such as endovascular mechanical thrombectomy, can be used for the emergent treatment of acute ischemic stroke. The comprehensive assessment of safety and effectiveness of deviceassisted treatments is complicated by several factors, including complex and unique neurovascular anatomy, the timing of stroke presentations, and variable tissue tolerability to ischemia. Realworld data (RWD) collected during routine medical care of patients presenting with acute ischemic stroke may be used to develop realworld evidence (RWE) to help evaluate the safety and effectiveness of deviceassisted treatments. The generated RWE may support postmarket surveillance requirements, identify potential adverse events, and perhaps guide regulatory decisions. For these reasons, the Center for Devices and Radiological Health (CDRH) at the Food and Drug Administration (FDA) recognizes the potential value of RWE and its use in the course of clinical and regulatory decisionmaking when appropriate. Coordinated Registry Networks (CRNs) allow for the systematic aggregation of highquality RWD which can in turn be analyzed, potentially leading to relevant and reliable evidence for the evaluation of medical devices. 5 Prompted by participation in two public meetings in late 2015, FDA Public Meeting on Acute Ischemic Stroke and the Stroke Treatment Academic Industry Roundtable, the FDA began to consider initiating a registry to advance acute ischemic stroke clinical trials and, where appropriate, to capture data necessary to support regulatory, reimbursement, coverage, and physician decisionmaking. On February 2, 2017, the FDA held a Public Workshop on a CRN for Devices used for Acute Ischemic Stroke Interventions (DAISICRN). The purpose for this workshop was to obtain initial public stakeholders’ input and plan for future collaboration. On November 9, 2017, a multistakeholder group convened to launch the DAISI initiative. The mission of the DAISI initiative is to establish a CRN using RWE generated in the clinical care domain by patients, physicians, providers, and payers, for the purposes of enhancing regulatory and clinical decisionmaking, improving healthcare, and supporting the development of innovative devices to treat acute ischemic stroke. This CRN will use national and international databases to capture information from patient encounters with medical devices used to treat acute ischemic stroke using common data elements (CDEs) related to patient characteristics, medical history, the procedure, preoperative and postoperative imaging, treatment devices, technical outcomes, and clinical followup needed in the CRN for the assessment of successful revascularization using endovascular mechanical thrombectomy devices.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用协调注册网络为评估用于急性缺血性卒中干预(DAISI)的设备奠定基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.80
自引率
0.00%
发文量
22
审稿时长
17 weeks
期刊最新文献
The impact of adjuvant antibiotic hydrogel application on the primary stability of uncemented hip stems. Prospective randomized evaluation of the sustained impact of assistive artificial intelligence on anesthetists' ultrasound scanning for regional anesthesia. Clinical effectiveness of a modified muscle sparing posterior technique compared with a standard lateral approach in hip hemiarthroplasty for displaced intracapsular fractures (HemiSPAIRE): a multicenter, parallel-group, randomized controlled trial. IDEAL evaluation for global surgery innovation. No frugal innovation without frugal evaluation: the Global IDEAL Sub-Framework.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1