Intraindividual variability of the Eustachian tube function: a longitudinal study in a pressure chamber.

IF 0.8 4区 医学 Q4 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH Diving and hyperbaric medicine Pub Date : 2023-03-31 DOI:10.28920/dhm53.1.24-30
Nele Peters, Stefanie Jansen, Jens P Klußmann, Moritz F Meyer
{"title":"Intraindividual variability of the Eustachian tube function: a longitudinal study in a pressure chamber.","authors":"Nele Peters, Stefanie Jansen, Jens P Klußmann, Moritz F Meyer","doi":"10.28920/dhm53.1.24-30","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The Eustachian tube (ET) is essential for fast and direct pressure equalisation between middle ear and ambient pressure. It is not yet known to what extent Eustachian tube function in healthy adults changes in a weekly periodicity due to internal and external factors. This question is particularly interesting with regard to scuba divers among whom there is a need to evaluate intraindividual ET function variability.</p><p><strong>Methods: </strong>Continuous impedance measurement in a pressure chamber was performed three times at one-week intervals between measurements. Twenty healthy participants (40 ears) were enrolled. Using a monoplace hyperbaric chamber, individual subjects were exposed to a standardised pressure profile consisting of a 20 kPa decompression over 1 min, a 40 kPa compression over 2 min, and a 20 kPa decompression over 1 min. Measurements of Eustachian tube opening pressure (ETOP), opening duration (ETOD), and opening frequency (ETOF) were made. Intraindividual variability was assessed.</p><p><strong>Results: </strong>Mean ETOD during compression (actively induced pressure equalisation) on the right side was 273.8 (SD 158.8) ms, 259.4 (157.7) ms, and 249.2 (154.1) ms (Chi-square 7.30, P = 0.026) across weeks 1-3. Mean ETOD for both sides was 265.6 (153.3) ms, 256.1 (154.6) ms, and 245.7 (147.8) ms (Chi-square 10.00, P = 0.007) across weeks 1-3. There were no other significant differences in ETOD, ETOP and ETOF across the three weekly measurements.</p><p><strong>Conclusions: </strong>This longitudinal study suggests low week-to-week intraindividual variability of Eustachian tube function.</p>","PeriodicalId":11296,"journal":{"name":"Diving and hyperbaric medicine","volume":"53 1","pages":"24-30"},"PeriodicalIF":0.8000,"publicationDate":"2023-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10325792/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diving and hyperbaric medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.28920/dhm53.1.24-30","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The Eustachian tube (ET) is essential for fast and direct pressure equalisation between middle ear and ambient pressure. It is not yet known to what extent Eustachian tube function in healthy adults changes in a weekly periodicity due to internal and external factors. This question is particularly interesting with regard to scuba divers among whom there is a need to evaluate intraindividual ET function variability.

Methods: Continuous impedance measurement in a pressure chamber was performed three times at one-week intervals between measurements. Twenty healthy participants (40 ears) were enrolled. Using a monoplace hyperbaric chamber, individual subjects were exposed to a standardised pressure profile consisting of a 20 kPa decompression over 1 min, a 40 kPa compression over 2 min, and a 20 kPa decompression over 1 min. Measurements of Eustachian tube opening pressure (ETOP), opening duration (ETOD), and opening frequency (ETOF) were made. Intraindividual variability was assessed.

Results: Mean ETOD during compression (actively induced pressure equalisation) on the right side was 273.8 (SD 158.8) ms, 259.4 (157.7) ms, and 249.2 (154.1) ms (Chi-square 7.30, P = 0.026) across weeks 1-3. Mean ETOD for both sides was 265.6 (153.3) ms, 256.1 (154.6) ms, and 245.7 (147.8) ms (Chi-square 10.00, P = 0.007) across weeks 1-3. There were no other significant differences in ETOD, ETOP and ETOF across the three weekly measurements.

Conclusions: This longitudinal study suggests low week-to-week intraindividual variability of Eustachian tube function.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
咽鼓管功能的个体内变异性:压力舱纵向研究。
简介咽鼓管(ET)对于快速、直接地平衡中耳和环境压力至关重要。目前尚不清楚健康成年人的咽鼓管功能每周会因内部和外部因素发生多大变化。这个问题对于水肺潜水员尤为重要,因为他们需要评估个体内部咽鼓管功能的变化:方法:在压力舱中进行三次连续阻抗测量,每次测量间隔一周。共招募了 20 名健康参与者(40 耳)。使用单点高压氧舱,受试者分别暴露在标准化的压力曲线下,包括 1 分钟内 20 kPa 的减压、2 分钟内 40 kPa 的加压和 1 分钟内 20 kPa 的减压。对咽鼓管开放压力(ETOP)、开放持续时间(ETOD)和开放频率(ETOF)进行了测量。对个体内部的变异性进行了评估:第 1-3 周,右侧压迫(主动诱导压力平衡)期间的平均 ETOD 分别为 273.8(标清 158.8)毫秒、259.4(157.7)毫秒和 249.2(154.1)毫秒(Chi-square 7.30,P = 0.026)。第 1-3 周,两侧的平均 ETOD 分别为 265.6 (153.3) ms、256.1 (154.6) ms 和 245.7 (147.8) ms(卡方 10.00,P = 0.007)。在每周的三次测量中,ETOD、ETOP 和 ETOF 没有其他明显差异:这项纵向研究表明,咽鼓管功能的周内个体间变异性较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Diving and hyperbaric medicine
Diving and hyperbaric medicine 医学-公共卫生、环境卫生与职业卫生
CiteScore
1.70
自引率
22.20%
发文量
37
审稿时长
>12 weeks
期刊介绍: Diving and Hyperbaric Medicine (DHM) is the combined journal of the South Pacific Underwater Medicine Society (SPUMS) and the European Underwater and Baromedical Society (EUBS). It seeks to publish papers of high quality on all aspects of diving and hyperbaric medicine of interest to diving medical professionals, physicians of all specialties, scientists, members of the diving and hyperbaric industries, and divers. Manuscripts must be offered exclusively to Diving and Hyperbaric Medicine, unless clearly authenticated copyright exemption accompaniesthe manuscript. All manuscripts will be subject to peer review. Accepted contributions will also be subject to editing.
期刊最新文献
Acoustic emission, an innovative diagnosis tool for therapeutic hyperbaric chambers: or how to requalify safely using pneumatic pressure test. Arterial dissection in scuba divers: a potential adverse manifestation of the physiological effects of immersion. Bispectral index with density spectral array (BIS-DSA) monitoring in a patient with inner ear and cerebral decompression sickness. Evaluation of a new hyperbaric oxygen ventilator during pressure-controlled ventilation. Hyperbaric medicine and climate footprint.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1