Impact of Cardiac Motion on coronary artery calcium scoring using a virtual non-iodine algorithm on photon-counting detector CT: a dynamic phantom study.

IF 1.5 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS International Journal of Cardiovascular Imaging Pub Date : 2023-10-01 Epub Date: 2023-07-15 DOI:10.1007/s10554-023-02912-z
Nicola Fink, Emese Zsarnoczay, U Joseph Schoepf, Jim O'Doherty, Moritz C Halfmann, Thomas Allmendinger, Junia Hagenauer, Joseph P Griffith, Milán Vecsey-Nagy, Daniel Pinos, Ullrich Ebersberger, Jens Ricke, Akos Varga-Szemes, Tilman Emrich
{"title":"Impact of Cardiac Motion on coronary artery calcium scoring using a virtual non-iodine algorithm on photon-counting detector CT: a dynamic phantom study.","authors":"Nicola Fink,&nbsp;Emese Zsarnoczay,&nbsp;U Joseph Schoepf,&nbsp;Jim O'Doherty,&nbsp;Moritz C Halfmann,&nbsp;Thomas Allmendinger,&nbsp;Junia Hagenauer,&nbsp;Joseph P Griffith,&nbsp;Milán Vecsey-Nagy,&nbsp;Daniel Pinos,&nbsp;Ullrich Ebersberger,&nbsp;Jens Ricke,&nbsp;Akos Varga-Szemes,&nbsp;Tilman Emrich","doi":"10.1007/s10554-023-02912-z","DOIUrl":null,"url":null,"abstract":"<p><p>This study assessed the impact of cardiac motion and in-vessel attenuation on coronary artery calcium (CAC) scoring using virtual non-iodine (VNI) against virtual non-contrast (VNC) reconstructions on photon-counting detector CT. Two artificial vessels containing calcifications and different in-vessel attenuations (500, 800HU) were scanned without (static) and with cardiac motion (60, 80, 100 beats per minute [bpm]). Images were post-processed using a VNC and VNI algorithm at 70 keV and quantum iterative reconstruction (QIR) strength 2. Calcium mass, Agatston scores, cardiac motion susceptibility (CMS)-indices were compared to physical mass, static scores as well as between reconstructions, heart rates and in-vessel attenuations. VNI scores decreased with rising heart rate (p < 0.01) and showed less underestimation than VNC scores (p < 0.001). Only VNI scores were similar to the physical mass at static measurements, and to static scores at 60 bpm. Agatston scores using VNI were similar to static scores at 60 and 80 bpm. Standard deviation of CMS-indices was lower for VNI-based than for VNC-based CAC scoring. VNI scores were higher at 500 than 800HU (p < 0.001) and higher than VNC scores (p < 0.001) with VNI scores at 500 HU showing the lowest deviation from the physical reference. VNI-based CAC quantification is influenced by cardiac motion and in-vessel attenuation, but least when measuring Agatston scores, where it outperforms VNC-based CAC scoring.</p>","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"2083-2092"},"PeriodicalIF":1.5000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Cardiovascular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10554-023-02912-z","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/15 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 2

Abstract

This study assessed the impact of cardiac motion and in-vessel attenuation on coronary artery calcium (CAC) scoring using virtual non-iodine (VNI) against virtual non-contrast (VNC) reconstructions on photon-counting detector CT. Two artificial vessels containing calcifications and different in-vessel attenuations (500, 800HU) were scanned without (static) and with cardiac motion (60, 80, 100 beats per minute [bpm]). Images were post-processed using a VNC and VNI algorithm at 70 keV and quantum iterative reconstruction (QIR) strength 2. Calcium mass, Agatston scores, cardiac motion susceptibility (CMS)-indices were compared to physical mass, static scores as well as between reconstructions, heart rates and in-vessel attenuations. VNI scores decreased with rising heart rate (p < 0.01) and showed less underestimation than VNC scores (p < 0.001). Only VNI scores were similar to the physical mass at static measurements, and to static scores at 60 bpm. Agatston scores using VNI were similar to static scores at 60 and 80 bpm. Standard deviation of CMS-indices was lower for VNI-based than for VNC-based CAC scoring. VNI scores were higher at 500 than 800HU (p < 0.001) and higher than VNC scores (p < 0.001) with VNI scores at 500 HU showing the lowest deviation from the physical reference. VNI-based CAC quantification is influenced by cardiac motion and in-vessel attenuation, but least when measuring Agatston scores, where it outperforms VNC-based CAC scoring.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在光子计数探测器CT上使用虚拟非碘算法对心脏运动对冠状动脉钙评分的影响:一项动态体模研究。
本研究评估了心脏运动和血管内衰减对冠状动脉钙(CAC)评分的影响,使用光子计数探测器CT上的虚拟非碘(VNI)和虚拟非对比(VNC)重建。两个含有钙化和不同血管内衰减(500800HU)的人造血管在无(静态)和有心脏运动(每分钟60、80、100次/分[bpm])的情况下进行扫描。使用70keV和量子迭代重建(QIR)强度为2的VNC和VNI算法对图像进行后处理。将钙质量、Agaston评分、心脏运动易感性(CMS)指数与物理质量、静态评分以及重建之间、心率和血管内衰减进行比较。VNI评分随着心率的升高而降低(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.00
自引率
9.50%
发文量
77
审稿时长
1 months
期刊介绍: The International Journal of Cardiovascular Imaging publishes technical and clinical communications (original articles, review articles and editorial comments) associated with cardiovascular diseases. The technical communications include the research, development and evaluation of novel imaging methods in the various imaging domains. These domains include magnetic resonance imaging, computed tomography, X-ray imaging, intravascular imaging, and applications in nuclear cardiology and echocardiography, and any combination of these techniques. Of particular interest are topics in medical image processing and image-guided interventions. Clinical applications of such imaging techniques include improved diagnostic approaches, treatment , prognosis and follow-up of cardiovascular patients. Topics include: multi-center or larger individual studies dealing with risk stratification and imaging utilization, applications for better characterization of cardiovascular diseases, and assessment of the efficacy of new drugs and interventional devices.
期刊最新文献
Usefulness of three-dimensional pulmonary vein-left atrium image reconstructed from non-enhanced computed tomography for atrial fibrillation ablation. Reproducibility of transthoracic 3D echocardiography in the assessment of mitral valve area in patients with rheumatic mitral stenosis: real time versus ECG-gated 3D echocardiography. Evaluation of an artificial intelligence-based system for echocardiographic estimation of right atrial pressure. Strain Echocardiography in Myocarditis with preserved left ventricular function. The prognostic value of coronary flow reserve in patients with non-obstructive coronary artery disease and microvascular dysfunction: a systematic review and meta-analysis with focus on imaging modality and sex difference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1