首页 > 最新文献

International Journal of Cardiovascular Imaging最新文献

英文 中文
Evaluation of an artificial intelligence-based system for echocardiographic estimation of right atrial pressure. 基于人工智能的超声心动图右房压评估系统的评价。
IF 2.1 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pub Date : 2023-12-01 Epub Date: 2023-09-08 DOI: 10.1007/s10554-023-02941-8
Ghada Zamzmi, Li-Yueh Hsu, Sivaramakrishnan Rajaraman, Wen Li, Vandana Sachdev, Sameer Antani

Current noninvasive estimation of right atrial pressure (RAP) by inferior vena cava (IVC) measurement during echocardiography may have significant inter-rater variability due to different levels of observers' experience. Therefore, there is a need to develop new approaches to decrease the variability of IVC analysis and RAP estimation. This study aims to develop a fully automated artificial intelligence (AI)-based system for automated IVC analysis and RAP estimation. We presented a multi-stage AI system to identify the IVC view, select good quality images, delineate the IVC region and quantify its thickness, enabling temporal tracking of its diameter and collapsibility changes. The automated system was trained and tested on expert manual IVC and RAP reference measurements obtained from 255 patients during routine clinical workflow. The performance was evaluated using Pearson correlation and Bland-Altman analysis for IVC values, as well as macro accuracy and chi-square test for RAP values. Our results show an excellent agreement (r=0.96) between automatically computed versus manually measured IVC values, and Bland-Altman analysis showed a small bias of [Formula: see text]0.33 mm. Further, there is an excellent agreement ([Formula: see text]) between automatically estimated versus manually derived RAP values with a macro accuracy of 0.85. The proposed AI-based system accurately quantified IVC diameter, collapsibility index, both are used for RAP estimation. This automated system could serve as a paradigm to perform IVC analysis in routine echocardiography and support various cardiac diagnostic applications.

目前超声心动图中通过下腔静脉(IVC)测量无创右房压(RAP)的方法,由于观察者经验水平的不同,可能存在显著的评分差异。因此,有必要开发新的方法来降低IVC分析和RAP估计的变异性。本研究旨在开发一个基于人工智能(AI)的全自动IVC分析和RAP估计系统。我们提出了一种多阶段人工智能系统来识别IVC视图,选择高质量的图像,描绘IVC区域并量化其厚度,从而实现对其直径和可折叠性变化的时间跟踪。在常规临床工作流程中,对该自动化系统进行了专家手动IVC和RAP参考测量的训练和测试。IVC值采用Pearson相关分析和Bland-Altman分析,RAP值采用宏观精度和卡方检验。我们的结果显示,自动计算的IVC值与人工测量的IVC值之间的一致性很好(r=0.96), Bland-Altman分析显示了0.33 mm的小偏差。此外,自动估计的RAP值与手动导出的RAP值之间存在非常好的一致性([公式:见文本]),宏观精度为0.85。本文提出的基于人工智能的系统准确量化了IVC直径和可折叠性指数,两者都用于RAP估计。该自动化系统可作为常规超声心动图中进行IVC分析的范例,并支持各种心脏诊断应用。
{"title":"Evaluation of an artificial intelligence-based system for echocardiographic estimation of right atrial pressure.","authors":"Ghada Zamzmi, Li-Yueh Hsu, Sivaramakrishnan Rajaraman, Wen Li, Vandana Sachdev, Sameer Antani","doi":"10.1007/s10554-023-02941-8","DOIUrl":"10.1007/s10554-023-02941-8","url":null,"abstract":"<p><p>Current noninvasive estimation of right atrial pressure (RAP) by inferior vena cava (IVC) measurement during echocardiography may have significant inter-rater variability due to different levels of observers' experience. Therefore, there is a need to develop new approaches to decrease the variability of IVC analysis and RAP estimation. This study aims to develop a fully automated artificial intelligence (AI)-based system for automated IVC analysis and RAP estimation. We presented a multi-stage AI system to identify the IVC view, select good quality images, delineate the IVC region and quantify its thickness, enabling temporal tracking of its diameter and collapsibility changes. The automated system was trained and tested on expert manual IVC and RAP reference measurements obtained from 255 patients during routine clinical workflow. The performance was evaluated using Pearson correlation and Bland-Altman analysis for IVC values, as well as macro accuracy and chi-square test for RAP values. Our results show an excellent agreement (r=0.96) between automatically computed versus manually measured IVC values, and Bland-Altman analysis showed a small bias of [Formula: see text]0.33 mm. Further, there is an excellent agreement ([Formula: see text]) between automatically estimated versus manually derived RAP values with a macro accuracy of 0.85. The proposed AI-based system accurately quantified IVC diameter, collapsibility index, both are used for RAP estimation. This automated system could serve as a paradigm to perform IVC analysis in routine echocardiography and support various cardiac diagnostic applications.</p>","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"2437-2450"},"PeriodicalIF":2.1,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10692014/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10173937","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Assessment of mitral valve geometry in nonvalvular atrial fibrillation patients with or without ventricular dysfunction: insights from high volume rate three-dimensional transesophageal echocardiography. 有或无心室功能障碍的非瓣膜性房颤患者二尖瓣几何形状的评估:高容积率三维经食管超声心动图的见解。
IF 2.1 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pub Date : 2023-12-01 Epub Date: 2023-09-04 DOI: 10.1007/s10554-023-02940-9
Wenjuan Bai, Ying Chen, Yue Zhong, Ling Deng, Dayan Li, Wei Zhu, Li Rao

Meticulous understanding of the mechanisms underpinning mitral regurgitation in atrial fibrillation (AF) patients is crucial to optimize therapeutic strategies. The morphologic characteristics of mitral valves in atrial functional mitral regurgitation (FMR) patients with and without left ventricular (LV) dysfunction were evaluated by high volume rate (HVR) three-dimensional transesophageal echocardiography (3D-TEE). In our study, 68 of 265 AF patients who underwent 3D-TEE were selected, including 36 patients with AF, FMR, and preserved LV function (AFMR group) and 32 patients with AF, FMR, and LV dysfunction (VFMR group). In addition, 36 fever patients without heart disease were included in the control group. Group comparisons were performed by one-way analysis of variance for continuous variables. The left atrium (LA) was enlarged in the AFMR and VFMR groups compared with the control group. The mitral annulus (MA) in the AFMR group was enlarged and flattened compared with the control group and was smaller than in the VFMR group. The annulus area fraction was significantly diminished in the AFMR and VFMR groups, indicative of reduced MA contractility. The posterior mitral leaflet (PML) angle was smallest in the AFMR group and largest in the control group, whereas the distal anterior mitral leaflet angle did not significantly differ among the three groups. LA remodeling causes expansion of the MA and reduced MA contractility, disruption of the annular saddle shape, and atriogenic PML tethering. Comparison of atrial FMR patients with and without LV dysfunction indicates that atriogenic PML tethering is an important factor that aggravates FMR. HVR 3D-TEE improves the 3D temporal resolution greatly.

细致了解心房颤动(AF)患者二尖瓣反流的机制对优化治疗策略至关重要。采用高容积率(HVR)三维经食管超声心动图(3D-TEE)评价心房功能性二尖瓣反流(FMR)伴和不伴左室功能不全患者二尖瓣形态学特征。本研究从265例房颤患者中选取68例行3D-TEE,其中房颤、FMR、左室功能保留患者36例(AFMR组),房颤、FMR、左室功能不全患者32例(vpmr组)。另外,36例无心脏疾病的发热患者作为对照组。组间比较采用连续变量的单因素方差分析。与对照组相比,AFMR组和VFMR组左心房(LA)增大。AFMR组二尖瓣环(MA)比对照组增大、变平,比VFMR组小。AFMR组和VFMR组的环面积分数显著降低,表明MA收缩性降低。AFMR组二尖瓣后叶(PML)角最小,对照组最大,而三组间二尖瓣远前叶角无显著差异。LA重塑导致MA扩张和MA收缩性降低,环形鞍状破坏,以及心房源性PML栓系。心房FMR患者合并和未合并左室功能障碍的比较表明,心房源性PML栓系是加重心房FMR的重要因素。HVR 3D- tee大大提高了三维时间分辨率。
{"title":"Assessment of mitral valve geometry in nonvalvular atrial fibrillation patients with or without ventricular dysfunction: insights from high volume rate three-dimensional transesophageal echocardiography.","authors":"Wenjuan Bai, Ying Chen, Yue Zhong, Ling Deng, Dayan Li, Wei Zhu, Li Rao","doi":"10.1007/s10554-023-02940-9","DOIUrl":"10.1007/s10554-023-02940-9","url":null,"abstract":"<p><p>Meticulous understanding of the mechanisms underpinning mitral regurgitation in atrial fibrillation (AF) patients is crucial to optimize therapeutic strategies. The morphologic characteristics of mitral valves in atrial functional mitral regurgitation (FMR) patients with and without left ventricular (LV) dysfunction were evaluated by high volume rate (HVR) three-dimensional transesophageal echocardiography (3D-TEE). In our study, 68 of 265 AF patients who underwent 3D-TEE were selected, including 36 patients with AF, FMR, and preserved LV function (AFMR group) and 32 patients with AF, FMR, and LV dysfunction (VFMR group). In addition, 36 fever patients without heart disease were included in the control group. Group comparisons were performed by one-way analysis of variance for continuous variables. The left atrium (LA) was enlarged in the AFMR and VFMR groups compared with the control group. The mitral annulus (MA) in the AFMR group was enlarged and flattened compared with the control group and was smaller than in the VFMR group. The annulus area fraction was significantly diminished in the AFMR and VFMR groups, indicative of reduced MA contractility. The posterior mitral leaflet (PML) angle was smallest in the AFMR group and largest in the control group, whereas the distal anterior mitral leaflet angle did not significantly differ among the three groups. LA remodeling causes expansion of the MA and reduced MA contractility, disruption of the annular saddle shape, and atriogenic PML tethering. Comparison of atrial FMR patients with and without LV dysfunction indicates that atriogenic PML tethering is an important factor that aggravates FMR. HVR 3D-TEE improves the 3D temporal resolution greatly.</p>","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"2427-2436"},"PeriodicalIF":2.1,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691988/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10500864","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Epicardial fat and Stage B heart failure among overweight/obese and normal weight individuals with diabetes mellitus. 超重/肥胖和体重正常的糖尿病患者心外膜脂肪和B期心力衰竭
IF 2.1 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pub Date : 2023-12-01 Epub Date: 2023-09-11 DOI: 10.1007/s10554-023-02944-5
Yukari Kobayashi, Tomoko Nishi, Jeffery W Christle, Nicholas Cauwenberghs, Tatiana Kuznetsova, Latha Palaniappan, Francois Haddad

Purpose: Although up to 20% of people with type 2 diabetes (DM) have normal BMI (< 25 kg/m2), it remains unclear whether there is a difference in the development of cardiac dysfunction between those with normal and higher BMI. Furthermore, little is known about the relationship of visceral fat with BMI or fitness in asymptomatic patients with DM.

Methods: We prospectively enrolled asymptomatic patients with DM and divided into two groups: BMI ≥ 25kg/m2 (overweight/obese group) versus < 25kg/m2(normal-weight group). Resting echocardiogram followed by exercise stress echocardiogram and exercise gas exchange analysis (in a subgroup) was performed. Cardiac function was evaluated using left ventricular longitudinal strain (LVLS), E/e', and relative wall thickness (RWT). In addition, epicardial fat thickness (EFT) was measured to estimate visceral fat.

Results: Normal-weight patients with DM had more EFT compared with overweight/obese patients (0.66 ± 0.17 cm vs. 0.59 ± 0.22 cm, p < 0.05), despite the overlap between the groups. There was no significant difference in the prevalence of LV remodeling (p = 0.49), impaired LVLS (p = 0.22), or increased E/e' (p = 0.26), and these were consistently observed when matched for race. The majority of patients (63%) achieved ≥ 85% of percent peak-predicted VO2. At peak, there was no significant difference in peak VO2 normalized by eLBM (36.4 ± 7.7 vs. 37.8 ± 7.1 ml/kg eLBM/min, p = 0.43) while VO2 normalized by weight (23.6 ± 6.5 vs. 29.6 ± 6.7 ml/kg/min, p < 0.001) and VO2 ratio (5.7 ± 1.7 vs. 7.3 ± 2.4 METs, p = 0.001) were significantly lower in patients with obese/overweight group. There was no significant difference between patients with higher and lower EFT.

Conclusions: Patients with DM and normal BMI have excess epicardial fat compared to those with overweight/obese. Epicardial fat was not directly linked to prevalence of subclinical dysfunction.

目的:尽管高达20%的2型糖尿病(DM)患者BMI正常(2),但目前尚不清楚BMI正常和较高的2型糖尿病患者在心功能障碍的发展方面是否存在差异。此外,对于无症状DM患者的内脏脂肪与BMI或健康的关系知之甚少。方法:我们前瞻性地招募无症状DM患者,并将其分为两组:BMI≥25kg/m2(超重/肥胖组)和2(正常体重组)。静息超声心动图、运动应激超声心动图和运动气体交换分析(亚组)。采用左心室纵应变(LVLS)、E/ E′和相对壁厚(RWT)评价心功能。此外,测量心外膜脂肪厚度(EFT)来估计内脏脂肪。结果:体重正常的糖尿病患者EFT高于超重/肥胖患者(0.66±0.17 cm vs 0.59±0.22 cm, p 2)。在峰值时,肥胖/超重组经eLBM归一化的VO2峰值(36.4±7.7 vs 37.8±7.1 ml/kg eLBM/min, p = 0.43)无显著差异,体重归一化的VO2峰值(23.6±6.5 vs 29.6±6.7 ml/kg/min, p = 0.001)显著降低。EFT高、低患者间无显著性差异。结论:与超重/肥胖患者相比,DM和正常BMI患者有多余的心外膜脂肪。心外膜脂肪与亚临床功能障碍患病率无直接关系。
{"title":"Epicardial fat and Stage B heart failure among overweight/obese and normal weight individuals with diabetes mellitus.","authors":"Yukari Kobayashi, Tomoko Nishi, Jeffery W Christle, Nicholas Cauwenberghs, Tatiana Kuznetsova, Latha Palaniappan, Francois Haddad","doi":"10.1007/s10554-023-02944-5","DOIUrl":"10.1007/s10554-023-02944-5","url":null,"abstract":"<p><strong>Purpose: </strong>Although up to 20% of people with type 2 diabetes (DM) have normal BMI (< 25 kg/m<sup>2</sup>), it remains unclear whether there is a difference in the development of cardiac dysfunction between those with normal and higher BMI. Furthermore, little is known about the relationship of visceral fat with BMI or fitness in asymptomatic patients with DM.</p><p><strong>Methods: </strong>We prospectively enrolled asymptomatic patients with DM and divided into two groups: BMI ≥ 25kg/m<sup>2</sup> (overweight/obese group) versus < 25kg/m<sup>2</sup>(normal-weight group). Resting echocardiogram followed by exercise stress echocardiogram and exercise gas exchange analysis (in a subgroup) was performed. Cardiac function was evaluated using left ventricular longitudinal strain (LVLS), E/e', and relative wall thickness (RWT). In addition, epicardial fat thickness (EFT) was measured to estimate visceral fat.</p><p><strong>Results: </strong>Normal-weight patients with DM had more EFT compared with overweight/obese patients (0.66 ± 0.17 cm vs. 0.59 ± 0.22 cm, p < 0.05), despite the overlap between the groups. There was no significant difference in the prevalence of LV remodeling (p = 0.49), impaired LVLS (p = 0.22), or increased E/e' (p = 0.26), and these were consistently observed when matched for race. The majority of patients (63%) achieved ≥ 85% of percent peak-predicted VO<sub>2</sub>. At peak, there was no significant difference in peak VO<sub>2</sub> normalized by eLBM (36.4 ± 7.7 vs. 37.8 ± 7.1 ml/kg eLBM/min, p = 0.43) while VO<sub>2</sub> normalized by weight (23.6 ± 6.5 vs. 29.6 ± 6.7 ml/kg/min, p < 0.001) and VO<sub>2</sub> ratio (5.7 ± 1.7 vs. 7.3 ± 2.4 METs, p = 0.001) were significantly lower in patients with obese/overweight group. There was no significant difference between patients with higher and lower EFT.</p><p><strong>Conclusions: </strong>Patients with DM and normal BMI have excess epicardial fat compared to those with overweight/obese. Epicardial fat was not directly linked to prevalence of subclinical dysfunction.</p>","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"2451-2461"},"PeriodicalIF":2.1,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11088949/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10571297","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Usefulness of three-dimensional pulmonary vein-left atrium image reconstructed from non-enhanced computed tomography for atrial fibrillation ablation. 非增强计算机断层扫描重建的三维肺静脉-左心房图像在房颤消融中的应用。
IF 2.1 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pub Date : 2023-12-01 Epub Date: 2023-08-30 DOI: 10.1007/s10554-023-02943-6
Souhei Kawafuji, Hirosuke Yamaji, Masaaki Kayama, Akitaka Akiyama, Motoaki Miyahara, Takumi Tomiya, Takuto Koumoto, Takuya Akagi, Shunichi Higashiya, Takashi Murakami, Shozo Kusachi

Enhanced computed tomography (CT) is unsuitable for patients with reduced renal function and/or allergy for contrast medium (CM). CT image registration into an electroanatomic system (EAMS) is essential to perform pulmonary vein isolation (PVI) safely and smoothly in patients with atrial fibrillation (AF). To create three-dimensional pulmonary vein-left atrium (3D PV-LA) images from non-enhanced CT images to register them into EAMS for AF ablation. Using a non-enhanced ECG-gated image, 3D PV-LA images were generated by our developed techniques with an EnSite image analyzing tool for patients unfit for CM use (n = 100). Segmentation between tissues was performed as follows: tissues distal from or close to PV-LA were segmented in transverse slices to clearly show the whole LA. Tissues bordering PV-LA, including the pulmonary artery, left ventricle, and right atrium, were segmented manually with great care. Practical ablation parameters were compared with those obtained from enhanced CT (n = 100). 3D PV-LA image reconstruction from non-enhanced CT imaging required a longer time than that from enhanced CT (42 ± 6 vs 14 ± 3 min). All 100 PV-LA non-enhanced CT images were successfully reconstructed and registered into the EAM system without the need for re-segmentation. Practical ablation parameters, including procedural time and AF recurrence rate, did not differ between imaging methods. This study provides clinically useful information on a detailed methodology for 3D PV-LA image reconstruction using non-enhanced CT. Non-enhanced CT 3D PV-LA images were successfully registered into the EAM system and useful for patients unsuitable for CM use.

增强计算机断层扫描(CT)不适合肾功能减退和/或对造影剂(CM)过敏的患者。CT图像配准到电子解剖系统(EAMS)对于房颤(AF)患者安全、顺利地进行肺静脉隔离(PVI)至关重要。从非增强CT图像创建三维肺静脉-左心房(3D PV-LA)图像,并将其登记到房颤消融的EAMS中。使用非增强的ecg门控图像,使用我们开发的技术和EnSite图像分析工具生成3D PV-LA图像,用于不适合CM使用的患者(n = 100)。组织间分割方法如下:在横向切片上对PV-LA远端或近端组织进行分割,以清晰显示整个LA。与PV-LA接壤的组织,包括肺动脉、左心室和右心房,都是非常小心地手工分割的。比较增强CT获得的实际消融参数(n = 100)。非增强CT重建三维PV-LA图像所需时间较增强CT长(42±6 min vs 14±3 min)。所有100张PV-LA非增强CT图像均成功重建并配准到EAM系统中,无需重新分割。实际消融参数,包括手术时间和房颤复发率,在不同的成像方法之间没有差异。本研究为使用非增强CT进行三维PV-LA图像重建的详细方法提供了临床有用的信息。非增强CT 3D PV-LA图像成功注册到EAM系统中,对不适合CM使用的患者有用。
{"title":"Usefulness of three-dimensional pulmonary vein-left atrium image reconstructed from non-enhanced computed tomography for atrial fibrillation ablation.","authors":"Souhei Kawafuji, Hirosuke Yamaji, Masaaki Kayama, Akitaka Akiyama, Motoaki Miyahara, Takumi Tomiya, Takuto Koumoto, Takuya Akagi, Shunichi Higashiya, Takashi Murakami, Shozo Kusachi","doi":"10.1007/s10554-023-02943-6","DOIUrl":"10.1007/s10554-023-02943-6","url":null,"abstract":"<p><p>Enhanced computed tomography (CT) is unsuitable for patients with reduced renal function and/or allergy for contrast medium (CM). CT image registration into an electroanatomic system (EAMS) is essential to perform pulmonary vein isolation (PVI) safely and smoothly in patients with atrial fibrillation (AF). To create three-dimensional pulmonary vein-left atrium (3D PV-LA) images from non-enhanced CT images to register them into EAMS for AF ablation. Using a non-enhanced ECG-gated image, 3D PV-LA images were generated by our developed techniques with an EnSite image analyzing tool for patients unfit for CM use (n = 100). Segmentation between tissues was performed as follows: tissues distal from or close to PV-LA were segmented in transverse slices to clearly show the whole LA. Tissues bordering PV-LA, including the pulmonary artery, left ventricle, and right atrium, were segmented manually with great care. Practical ablation parameters were compared with those obtained from enhanced CT (n = 100). 3D PV-LA image reconstruction from non-enhanced CT imaging required a longer time than that from enhanced CT (42 ± 6 vs 14 ± 3 min). All 100 PV-LA non-enhanced CT images were successfully reconstructed and registered into the EAM system without the need for re-segmentation. Practical ablation parameters, including procedural time and AF recurrence rate, did not differ between imaging methods. This study provides clinically useful information on a detailed methodology for 3D PV-LA image reconstruction using non-enhanced CT. Non-enhanced CT 3D PV-LA images were successfully registered into the EAM system and useful for patients unsuitable for CM use.</p>","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"2517-2526"},"PeriodicalIF":2.1,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10104773","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Strain Echocardiography in Myocarditis with preserved left ventricular function. 保留左心室功能的心肌炎的应变超声心动图分析。
IF 2.1 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pub Date : 2023-12-01 Epub Date: 2023-09-11 DOI: 10.1007/s10554-023-02945-4
Özden Seçkin Göbüt, Serkan Ünlü
{"title":"Strain Echocardiography in Myocarditis with preserved left ventricular function.","authors":"Özden Seçkin Göbüt, Serkan Ünlü","doi":"10.1007/s10554-023-02945-4","DOIUrl":"10.1007/s10554-023-02945-4","url":null,"abstract":"","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"2463-2464"},"PeriodicalIF":2.1,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10194445","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Reproducibility of transthoracic 3D echocardiography in the assessment of mitral valve area in patients with rheumatic mitral stenosis: real time versus ECG-gated 3D echocardiography. 经胸三维超声心动图评估风湿性二尖瓣狭窄患者二尖瓣面积的可重复性:实时与ecg门控三维超声心动图对比
IF 2.1 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pub Date : 2023-12-01 Epub Date: 2023-09-02 DOI: 10.1007/s10554-023-02939-2
Nidhal Bouchahda, Marwa Jarraya, Yessine Kallala, Ghada Sassi, Mehdi Boussaada, Mouna Bader, Marwen Mahjoub, Hassen Haj, Imen Zemni, Fethi Betbout, Habib Gamra, Majed Hassine, Mejdi Ben Messaoud

Purpose: To assess reproducibility of Real time 3D echocardiography (RT3D) and ECG-gated 3D echocardiography (EG3D) when measuring the mitral valve area (MVA) in rheumatic mitral stenosis (MS).

Methods: MVA was assessed by three operators in 68 MS patients using RT3D and EG3D. Reproducibility of each technique was determined by calculating the standard error of measurements (SEM).

Results: SEM was similar between RT3D and EG3D. MVA variability was of 0.4 cm² or 30% of any RT3D or EG3D measured MVA. The minimal change in MVA above which two measurements should be considered to differ significantly for the same operator was of 0.4 cm² for RT3D and 0.5 cm² for EG3D. For two different operators making successive measurements, the minimum significant change was of 0.5 cm² for RT3D and 0.6 cm² for EG3D. The minimum significant difference when switching from RT3D to EG3D or vice versa is of 0.6 cm². Low temporal resolution of 6 Hz has the least variability when using RT3D (0.19 cm² vs. 0.26 cm², p = 0.009) but significantly underestimated MVA (1.3 ± 0.4 cm² vs. 1.4 ± 0.4 cm², p < 10- 3) when compared to EG3D. MVA variability was significantly higher in mild MS when compared to severe MS whether it is RT3D (0.23 cm² vs. 0.18 cm², p = 0.02) or EG3D (0.27 cm² vs. 0.16 cm², p < 0.001).

Conclusion: RT3D and EG3D are equally reproducible in the assessment of MVA in patients with MS. Further measurements standardization is required to have a clinically acceptable estimations of the true 3D MVA and minimal detectable differences.

目的:评价实时三维超声心动图(RT3D)和心电图门控三维超声心动图(EG3D)测量风湿性二尖瓣狭窄(MS)患者二尖瓣面积(MVA)的可重复性。方法:采用RT3D和EG3D技术对68例MS患者进行MVA评估。通过计算测量标准误差(SEM)来确定每种技术的重复性。结果:RT3D与EG3D扫描电镜相似。MVA变异性为0.4 cm²或任何RT3D或EG3D测量的MVA的30%。RT3D的MVA最小变化为0.4 cm²,EG3D的MVA最小变化为0.5 cm²,这两个测量值应该被认为是同一操作员的显著差异。对于连续测量的两种不同操作人员,RT3D的最小显著变化为0.5 cm²,EG3D的最小显著变化为0.6 cm²。当从RT3D切换到EG3D或反之亦然时,最小的显著差异为0.6 cm²。使用RT3D时,低时间分辨率为6 Hz的变异性最小(0.19 cm²vs 0.26 cm²,p = 0.009),但与EG3D相比,显著低估了MVA(1.3±0.4 cm²vs 1.4±0.4 cm²,p - 3)。无论是RT3D (0.23 cm²vs. 0.18 cm²,p = 0.02)还是EG3D (0.27 cm²vs. 0.16 cm²,p),轻度MS的MVA变异性明显高于重度MS。结论:RT3D和EG3D在MS患者MVA评估中具有同样的可重复性,需要进一步的测量标准化,以获得临床可接受的真实3D MVA估计和最小可检测差异。
{"title":"Reproducibility of transthoracic 3D echocardiography in the assessment of mitral valve area in patients with rheumatic mitral stenosis: real time versus ECG-gated 3D echocardiography.","authors":"Nidhal Bouchahda, Marwa Jarraya, Yessine Kallala, Ghada Sassi, Mehdi Boussaada, Mouna Bader, Marwen Mahjoub, Hassen Haj, Imen Zemni, Fethi Betbout, Habib Gamra, Majed Hassine, Mejdi Ben Messaoud","doi":"10.1007/s10554-023-02939-2","DOIUrl":"10.1007/s10554-023-02939-2","url":null,"abstract":"<p><strong>Purpose: </strong>To assess reproducibility of Real time 3D echocardiography (RT3D) and ECG-gated 3D echocardiography (EG3D) when measuring the mitral valve area (MVA) in rheumatic mitral stenosis (MS).</p><p><strong>Methods: </strong>MVA was assessed by three operators in 68 MS patients using RT3D and EG3D. Reproducibility of each technique was determined by calculating the standard error of measurements (SEM).</p><p><strong>Results: </strong>SEM was similar between RT3D and EG3D. MVA variability was of 0.4 cm² or 30% of any RT3D or EG3D measured MVA. The minimal change in MVA above which two measurements should be considered to differ significantly for the same operator was of 0.4 cm² for RT3D and 0.5 cm² for EG3D. For two different operators making successive measurements, the minimum significant change was of 0.5 cm² for RT3D and 0.6 cm² for EG3D. The minimum significant difference when switching from RT3D to EG3D or vice versa is of 0.6 cm². Low temporal resolution of 6 Hz has the least variability when using RT3D (0.19 cm² vs. 0.26 cm², p = 0.009) but significantly underestimated MVA (1.3 ± 0.4 cm² vs. 1.4 ± 0.4 cm², p < 10<sup>- 3</sup>) when compared to EG3D. MVA variability was significantly higher in mild MS when compared to severe MS whether it is RT3D (0.23 cm² vs. 0.18 cm², p = 0.02) or EG3D (0.27 cm² vs. 0.16 cm², p < 0.001).</p><p><strong>Conclusion: </strong>RT3D and EG3D are equally reproducible in the assessment of MVA in patients with MS. Further measurements standardization is required to have a clinically acceptable estimations of the true 3D MVA and minimal detectable differences.</p>","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"2419-2426"},"PeriodicalIF":2.1,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10142954","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The prognostic value of coronary flow reserve in patients with non-obstructive coronary artery disease and microvascular dysfunction: a systematic review and meta-analysis with focus on imaging modality and sex difference. 冠状动脉血流储备对非阻塞性冠状动脉疾病和微血管功能障碍患者的预后价值:一项系统回顾和荟萃分析,重点关注成像方式和性别差异。
IF 2.1 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pub Date : 2023-12-01 Epub Date: 2023-09-16 DOI: 10.1007/s10554-023-02948-1
Signe Miang Jensen, Eva Irene Bossano Prescott, Jawdat Abdulla

To clarify prognosis of patients with non-obstructive coronary artery disease (NOCAD) and coronary microvascular disease (CMD) assessed as low coronary flow reserve (CFR) according to imaging modalities and sex difference. Comprehensive systematic literature review and meta-analyses were conducted. Risk of death and major adverse cardiac events (MACE) were pooled and compared in patients with abnormally low versus normal CFR using cut-off limits 2.0-2.5. Random effects model used for estimation of odds ratios (OR) and hazard ratios (HR) with 95% confidence interval (CI). Nineteen eligible observational studies provided data for death and MACE, publication bias was insignificant, p = 0.62. Risk of death and MACE were significantly higher in patients with low (n = 4.612, 29%) than normal CFR (n = 11.367, 71%): using transthoracal echocardiography (TTE) (OR 4.25 (95% CI 2.94, 6.15) p < 0.001) and (OR 6.98 (95% CI 2.56, 19.01) p < 0.001), positron emission tomography (PET) (OR 2.51 (CI 95%: 1.40, 4..49) p = 0.002) and (OR 2.87 (95% CI 2.16, 3.81) p < 0.001), and invasive intracoronary assessment (OR 2.23 (95% CI 1.15, 4.34) p < 0.018), and (OR 4.61 (95% CI 2.51, 8.48) p < 0.001), respectively. Pooled adjusted HR for death and MACE were (HR 2.45(95% CI 1.37, 3.53) p < 0.001) and (HR 2.08 (95% CI 1.54, 2.63) p < 0.001) respectively. Studies comparing men and women with abnormally low CFR demonstrated similar worse prognosis in both sexes. Low CFR is associated with poorer prognosis in patients with NOCAD regardless of sex. TTE may overestimate risk of death and MACE, while PET seems to be more appropriate. Future studies are needed to consolidate the current evidence.

目的探讨非阻塞性冠状动脉疾病(NOCAD)和冠状动脉微血管疾病(CMD)在低冠状动脉血流储备(CFR)诊断中的影像学表现及性别差异对预后的影响。进行了全面系统的文献综述和荟萃分析。将CFR异常低与正常患者的死亡风险和主要心脏不良事件(MACE)进行汇总,并采用2.0-2.5的临界值进行比较。随机效应模型用于估计95%可信区间(CI)的优势比(OR)和风险比(HR)。19项符合条件的观察性研究提供了死亡和MACE的数据,发表偏倚不显著,p = 0.62。低CFR患者(n = 4.612, 29%)的死亡和MACE风险显著高于正常CFR患者(n = 11.367, 71%):经胸超声心动图(TTE) (OR 4.25 (95% CI 2.94, 6.15) p
{"title":"The prognostic value of coronary flow reserve in patients with non-obstructive coronary artery disease and microvascular dysfunction: a systematic review and meta-analysis with focus on imaging modality and sex difference.","authors":"Signe Miang Jensen, Eva Irene Bossano Prescott, Jawdat Abdulla","doi":"10.1007/s10554-023-02948-1","DOIUrl":"10.1007/s10554-023-02948-1","url":null,"abstract":"<p><p>To clarify prognosis of patients with non-obstructive coronary artery disease (NOCAD) and coronary microvascular disease (CMD) assessed as low coronary flow reserve (CFR) according to imaging modalities and sex difference. Comprehensive systematic literature review and meta-analyses were conducted. Risk of death and major adverse cardiac events (MACE) were pooled and compared in patients with abnormally low versus normal CFR using cut-off limits 2.0-2.5. Random effects model used for estimation of odds ratios (OR) and hazard ratios (HR) with 95% confidence interval (CI). Nineteen eligible observational studies provided data for death and MACE, publication bias was insignificant, p = 0.62. Risk of death and MACE were significantly higher in patients with low (n = 4.612, 29%) than normal CFR (n = 11.367, 71%): using transthoracal echocardiography (TTE) (OR 4.25 (95% CI 2.94, 6.15) p < 0.001) and (OR 6.98 (95% CI 2.56, 19.01) p < 0.001), positron emission tomography (PET) (OR 2.51 (CI 95%: 1.40, 4..49) p = 0.002) and (OR 2.87 (95% CI 2.16, 3.81) p < 0.001), and invasive intracoronary assessment (OR 2.23 (95% CI 1.15, 4.34) p < 0.018), and (OR 4.61 (95% CI 2.51, 8.48) p < 0.001), respectively. Pooled adjusted HR for death and MACE were (HR 2.45(95% CI 1.37, 3.53) p < 0.001) and (HR 2.08 (95% CI 1.54, 2.63) p < 0.001) respectively. Studies comparing men and women with abnormally low CFR demonstrated similar worse prognosis in both sexes. Low CFR is associated with poorer prognosis in patients with NOCAD regardless of sex. TTE may overestimate risk of death and MACE, while PET seems to be more appropriate. Future studies are needed to consolidate the current evidence.</p>","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"2545-2556"},"PeriodicalIF":2.1,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10272482","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluation of myocardial strain in patients with subclinical hypertrophic cardiomyopathy and subclinical Hypertensive Heart Disease using Cardiac magnetic resonance feature tracking. 应用心脏磁共振特征跟踪评价亚临床肥厚性心肌病和亚临床高血压性心脏病患者的心肌应变
IF 2.1 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pub Date : 2023-11-01 Epub Date: 2023-09-08 DOI: 10.1007/s10554-023-02930-x
Xiaoyong Hao, Jiang Wu, Lina Zhu, Xuan Li

The evaluation of cardiac magnetic resonance feature tracking may have great diagnostic value in hypertrophic cardiomyopathy and hypertensive heart disease. Exploring the diagnostic and clinical research value of cardiac magnetic resonance feature tracks in evaluation of myocardium deformation in patients with subclinical hypertrophic cardiomyopathy(SHCM)and subclinical hypertensive heart disease(SHHD). Cardiovascular Magnetic Resonance (CMR) scans were performed on a 1.5 T MR scanner in 33 patients with SHCM, 31 patients with SHHD, and 27 controls(NS). The CMR image post-processing software was used to analyze the characteristics of routine cardiac function, different global and regional myocardial strain in each group. Analysis of variance (ANOVA) was used to compare age, blood pressure, heart rate, routine cardiac function, body mass index (BMI), as well as the strain between different segments within each of the three groups. Once a significant difference was detected, a least significant difference (LSD) comparison would be performed. The diagnostic efficacy of different parameters in differentiating SHHD from SHCM was evaluated through receiver operating characteristic (ROC) curve analysis, and the best cut-off value was determined. There was no statistical difference among three groups (P>0.05) in routine cardiac function while significant statistical differences were found in the global myocardial strain parameters and the peak strain parameters of some segments (especially basal segments) (P < 0.05). The global radial peak strain (GRPS) was most effective (AUC = 0.885, 95% CI: 0.085-0.971, P<0.001) with a sensitivity and specificity of 84% and 88% at a cut-off value of 40.105, contributing to distinguishing SHCM from SHHD group. Cardiac magnetic resonance feature tracking could detect left ventricular deformation in patients with SHCM and SHHD group. The abnormality of strain has important research value for subclinical diagnosis and clinical evaluation.

心脏磁共振特征跟踪的评价对肥厚性心肌病和高血压性心脏病有很大的诊断价值。探讨心脏磁共振特征迹线在评价亚临床肥厚性心肌病(SHCM)和亚临床高血压性心脏病(SHHD)患者心肌变形中的诊断和临床研究价值。33例SHCM患者、31例SHHD患者和27例对照(NS)在1.5 T MR扫描仪上进行心血管磁共振(CMR)扫描。采用CMR图像后处理软件分析各组常规心功能、不同整体及局部心肌应变的特点。采用方差分析(ANOVA)比较三组患者的年龄、血压、心率、常规心功能、体重指数(BMI)以及不同节段之间的应变。一旦检测到显著差异,将进行最低显著差异(LSD)比较。通过受试者工作特征(ROC)曲线分析,评价不同参数对SHHD与SHCM的诊断效果,确定最佳截断值。三组患者常规心功能差异无统计学意义(P>0.05),但心肌总应变参数及部分节段(尤其是基底节段)峰值应变参数差异有统计学意义(P>0.05)
{"title":"Evaluation of myocardial strain in patients with subclinical hypertrophic cardiomyopathy and subclinical Hypertensive Heart Disease using Cardiac magnetic resonance feature tracking.","authors":"Xiaoyong Hao, Jiang Wu, Lina Zhu, Xuan Li","doi":"10.1007/s10554-023-02930-x","DOIUrl":"10.1007/s10554-023-02930-x","url":null,"abstract":"<p><p>The evaluation of cardiac magnetic resonance feature tracking may have great diagnostic value in hypertrophic cardiomyopathy and hypertensive heart disease. Exploring the diagnostic and clinical research value of cardiac magnetic resonance feature tracks in evaluation of myocardium deformation in patients with subclinical hypertrophic cardiomyopathy(SHCM)and subclinical hypertensive heart disease(SHHD). Cardiovascular Magnetic Resonance (CMR) scans were performed on a 1.5 T MR scanner in 33 patients with SHCM, 31 patients with SHHD, and 27 controls(NS). The CMR image post-processing software was used to analyze the characteristics of routine cardiac function, different global and regional myocardial strain in each group. Analysis of variance (ANOVA) was used to compare age, blood pressure, heart rate, routine cardiac function, body mass index (BMI), as well as the strain between different segments within each of the three groups. Once a significant difference was detected, a least significant difference (LSD) comparison would be performed. The diagnostic efficacy of different parameters in differentiating SHHD from SHCM was evaluated through receiver operating characteristic (ROC) curve analysis, and the best cut-off value was determined. There was no statistical difference among three groups (P>0.05) in routine cardiac function while significant statistical differences were found in the global myocardial strain parameters and the peak strain parameters of some segments (especially basal segments) (P < 0.05). The global radial peak strain (GRPS) was most effective (AUC = 0.885, 95% CI: 0.085-0.971, P<0.001) with a sensitivity and specificity of 84% and 88% at a cut-off value of 40.105, contributing to distinguishing SHCM from SHHD group. Cardiac magnetic resonance feature tracking could detect left ventricular deformation in patients with SHCM and SHHD group. The abnormality of strain has important research value for subclinical diagnosis and clinical evaluation.</p>","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"2237-2246"},"PeriodicalIF":2.1,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10173935","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
How the trabeculae protrude within the left atrial appendage is the key factor affecting thrombosis in patients with atrial fibrillation. 房颤患者左房耳内小梁如何突出是影响房颤患者血栓形成的关键因素。
IF 2.1 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pub Date : 2023-11-01 Epub Date: 2023-09-04 DOI: 10.1007/s10554-023-02933-8
Juanzhang Liu, Taihui Yu, Chaodi Tan, Hongwei Li, Yuping Zheng, Shaoxin Zheng, Kexin Wen, Jingfeng Wang, Dengfeng Geng, Shuxian Zhou

The left atrial appendage (LAA) is a major site of thrombosis in patients with non-valvular atrial fibrillation. The myocardial trabeculae within the LAA have a peculiar tendency to protrude but its relationship to thrombosis remains unknown. This study aimed to investigate the relationship between the condition of trabeculae protrusion and LAA thrombosis. This retrospective study consecutively selected patients diagnosed with non-valvular atrial fibrillation and prepared for radiofrequency ablation from January 2011 to May 2020. Patients were divided into the thrombus group (n = 43), the sludge group (n = 35), and the normal group (n = 407) according to whether the thrombus or sludge was present. The trabeculae protruding angle (TPA), which was measured by the CT scans, was used to quantify the trabeculae protrusion condition. Patients' clinical data, TPA, LAA emptying velocity, and other factors were collected and compared among the three groups. A total of 485 patients were enrolled. The range of TPA was between 0 and 158 degrees, with an average of 89.3 ± 35.6 degrees. The TPA was significantly greater in the thrombus (109.3 ± 14.8 degrees) and sludge groups (110.8 ± 12.8 degrees) than in the normal group (85.3 ± 37.1). The incidence of LAA thrombus and sludge increased with increasing TPA. Multivariate regression analysis showed that the TPA was an independent risk factor for LAA thrombus (OR = 1.046, 95%CI: 1.020-1.073, p < 0.001) and sludge (OR = 1.035, 95%CI: 1.017-1.053, p < 0.001). Further analysis revealed that the TPA was negatively correlated with LAA emptying velocity but its effect on promoting thrombosis was not only mediated by slowing down the flow velocity. The TPA can well reflect the condition of trabeculae protrusion. This study revealed that the TPA was an independent risk factor for LAA thrombus or sludge, providing a potential indicator for future thrombosis risk assessment.

左心耳(LAA)是非瓣膜性心房颤动患者血栓形成的主要部位。LAA内的心肌小梁有特殊的突出倾向,但其与血栓形成的关系尚不清楚。本研究旨在探讨小梁突出与LAA血栓形成的关系。本回顾性研究连续选择2011年1月至2020年5月诊断为非瓣膜性心房颤动并准备射频消融的患者。根据是否存在血栓或污泥将患者分为血栓组(n = 43)、污泥组(n = 35)和正常组(n = 407)。通过CT扫描测量小梁突出角(TPA)来量化小梁突出情况。收集三组患者的临床资料、TPA、LAA排空速度等因素进行比较。共有485名患者入组。TPA范围为0 ~ 158度,平均为89.3±35.6度。血栓组TPA(109.3±14.8度)和污泥组TPA(110.8±12.8度)明显高于正常组(85.3±37.1度)。LAA血栓和污泥的发生率随TPA的增加而增加。多因素回归分析显示TPA是LAA血栓形成的独立危险因素(OR = 1.046, 95%CI: 1.020 ~ 1.073, p
{"title":"How the trabeculae protrude within the left atrial appendage is the key factor affecting thrombosis in patients with atrial fibrillation.","authors":"Juanzhang Liu, Taihui Yu, Chaodi Tan, Hongwei Li, Yuping Zheng, Shaoxin Zheng, Kexin Wen, Jingfeng Wang, Dengfeng Geng, Shuxian Zhou","doi":"10.1007/s10554-023-02933-8","DOIUrl":"10.1007/s10554-023-02933-8","url":null,"abstract":"<p><p>The left atrial appendage (LAA) is a major site of thrombosis in patients with non-valvular atrial fibrillation. The myocardial trabeculae within the LAA have a peculiar tendency to protrude but its relationship to thrombosis remains unknown. This study aimed to investigate the relationship between the condition of trabeculae protrusion and LAA thrombosis. This retrospective study consecutively selected patients diagnosed with non-valvular atrial fibrillation and prepared for radiofrequency ablation from January 2011 to May 2020. Patients were divided into the thrombus group (n = 43), the sludge group (n = 35), and the normal group (n = 407) according to whether the thrombus or sludge was present. The trabeculae protruding angle (TPA), which was measured by the CT scans, was used to quantify the trabeculae protrusion condition. Patients' clinical data, TPA, LAA emptying velocity, and other factors were collected and compared among the three groups. A total of 485 patients were enrolled. The range of TPA was between 0 and 158 degrees, with an average of 89.3 ± 35.6 degrees. The TPA was significantly greater in the thrombus (109.3 ± 14.8 degrees) and sludge groups (110.8 ± 12.8 degrees) than in the normal group (85.3 ± 37.1). The incidence of LAA thrombus and sludge increased with increasing TPA. Multivariate regression analysis showed that the TPA was an independent risk factor for LAA thrombus (OR = 1.046, 95%CI: 1.020-1.073, p < 0.001) and sludge (OR = 1.035, 95%CI: 1.017-1.053, p < 0.001). Further analysis revealed that the TPA was negatively correlated with LAA emptying velocity but its effect on promoting thrombosis was not only mediated by slowing down the flow velocity. The TPA can well reflect the condition of trabeculae protrusion. This study revealed that the TPA was an independent risk factor for LAA thrombus or sludge, providing a potential indicator for future thrombosis risk assessment.</p>","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"2259-2267"},"PeriodicalIF":2.1,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10500869","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Standardized medical terminology for cardiac computed tomography 2023 update- commentary by North American Society of Cardiovascular Imaging (NASCI). 心脏计算机断层扫描标准化医学术语2023年更新-北美心血管成像学会(NASCI)评论。
IF 2.1 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pub Date : 2023-11-01 DOI: 10.1007/s10554-023-02922-x
Archana Rai, Bradley D Allen, Cristina Fuss, Carole Dennie, Kate Hanneman
{"title":"Standardized medical terminology for cardiac computed tomography 2023 update- commentary by North American Society of Cardiovascular Imaging (NASCI).","authors":"Archana Rai, Bradley D Allen, Cristina Fuss, Carole Dennie, Kate Hanneman","doi":"10.1007/s10554-023-02922-x","DOIUrl":"10.1007/s10554-023-02922-x","url":null,"abstract":"","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"2255-2257"},"PeriodicalIF":2.1,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10368337","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
期刊
International Journal of Cardiovascular Imaging
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1