{"title":"A comparative study of robot-assisted and traditional surgeries in the treatment of thoracolumbar fractures based on 1-year follow-up observation.","authors":"Xu-Qi Hu, Hui-Gen Lu, Xiao Zhou, Min-Jie Hu, Xue-Kang Pan, Bao Chen, Ye-Feng Yu","doi":"10.3233/BME-222521","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There are conflicting results for robot-assisted (RA) pedicle screw fixation compared with freehand (FH) pedicle screw fixation.</p><p><strong>Objective: </strong>This study was designed to retrospectively compare the accuracy and efficacy of RA percutaneous pedicle screw fixation and traditional freehand FH pedicle screw fixation in the treatment of thoracolumbar fractures.</p><p><strong>Methods: </strong>A total of 26 cases were assigned to the RA group, and 24 cases were assigned to the FH group. The operation time, bleeding volume, and visual analog scale (VAS) score 1 day after the operation, and the anterior/posterior (A/P) vertebral height ratio of the injured vertebrae at 3 days and at internal fixation removal 1 year after the operation were compared between the two groups. Pedicle screw position accuracy was assessed according to Gertzbein criteria.</p><p><strong>Results: </strong>The operation times of the RA group and FH group were 138.69 ± 32.67 minutes and 103.67 ± 14.53 minutes, respectively, and the difference was statistically significant. The intraoperative blood loss was 49.23 ± 22.56 ml in the RA group and 78.33 ± 23.90 ml in the FH group, and the difference was statistically significant. There was a significant difference in the A/P vertebral height ratio of the injured vertebrae 3 days after the operation compared with before the operation in both groups (P < 0.05). There was a significant difference in the A/P vertebral height ratio of the injured vertebrae 3 days after the operation compared with that at fixation removal in both groups (P < 0.05).</p><p><strong>Conclusion: </strong>The application of RA orthopedic treatment for thoracolumbar fractures can achieve good fracture reduction.</p>","PeriodicalId":9109,"journal":{"name":"Bio-medical materials and engineering","volume":"34 4","pages":"375-383"},"PeriodicalIF":1.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bio-medical materials and engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/BME-222521","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: There are conflicting results for robot-assisted (RA) pedicle screw fixation compared with freehand (FH) pedicle screw fixation.
Objective: This study was designed to retrospectively compare the accuracy and efficacy of RA percutaneous pedicle screw fixation and traditional freehand FH pedicle screw fixation in the treatment of thoracolumbar fractures.
Methods: A total of 26 cases were assigned to the RA group, and 24 cases were assigned to the FH group. The operation time, bleeding volume, and visual analog scale (VAS) score 1 day after the operation, and the anterior/posterior (A/P) vertebral height ratio of the injured vertebrae at 3 days and at internal fixation removal 1 year after the operation were compared between the two groups. Pedicle screw position accuracy was assessed according to Gertzbein criteria.
Results: The operation times of the RA group and FH group were 138.69 ± 32.67 minutes and 103.67 ± 14.53 minutes, respectively, and the difference was statistically significant. The intraoperative blood loss was 49.23 ± 22.56 ml in the RA group and 78.33 ± 23.90 ml in the FH group, and the difference was statistically significant. There was a significant difference in the A/P vertebral height ratio of the injured vertebrae 3 days after the operation compared with before the operation in both groups (P < 0.05). There was a significant difference in the A/P vertebral height ratio of the injured vertebrae 3 days after the operation compared with that at fixation removal in both groups (P < 0.05).
Conclusion: The application of RA orthopedic treatment for thoracolumbar fractures can achieve good fracture reduction.
期刊介绍:
The aim of Bio-Medical Materials and Engineering is to promote the welfare of humans and to help them keep healthy. This international journal is an interdisciplinary journal that publishes original research papers, review articles and brief notes on materials and engineering for biological and medical systems. Articles in this peer-reviewed journal cover a wide range of topics, including, but not limited to: Engineering as applied to improving diagnosis, therapy, and prevention of disease and injury, and better substitutes for damaged or disabled human organs; Studies of biomaterial interactions with the human body, bio-compatibility, interfacial and interaction problems; Biomechanical behavior under biological and/or medical conditions; Mechanical and biological properties of membrane biomaterials; Cellular and tissue engineering, physiological, biophysical, biochemical bioengineering aspects; Implant failure fields and degradation of implants. Biomimetics engineering and materials including system analysis as supporter for aged people and as rehabilitation; Bioengineering and materials technology as applied to the decontamination against environmental problems; Biosensors, bioreactors, bioprocess instrumentation and control system; Application to food engineering; Standardization problems on biomaterials and related products; Assessment of reliability and safety of biomedical materials and man-machine systems; and Product liability of biomaterials and related products.