{"title":"A comparative study of robot-assisted and traditional surgeries in the treatment of thoracolumbar fractures based on 1-year follow-up observation.","authors":"Xu-Qi Hu,&nbsp;Hui-Gen Lu,&nbsp;Xiao Zhou,&nbsp;Min-Jie Hu,&nbsp;Xue-Kang Pan,&nbsp;Bao Chen,&nbsp;Ye-Feng Yu","doi":"10.3233/BME-222521","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There are conflicting results for robot-assisted (RA) pedicle screw fixation compared with freehand (FH) pedicle screw fixation.</p><p><strong>Objective: </strong>This study was designed to retrospectively compare the accuracy and efficacy of RA percutaneous pedicle screw fixation and traditional freehand FH pedicle screw fixation in the treatment of thoracolumbar fractures.</p><p><strong>Methods: </strong>A total of 26 cases were assigned to the RA group, and 24 cases were assigned to the FH group. The operation time, bleeding volume, and visual analog scale (VAS) score 1 day after the operation, and the anterior/posterior (A/P) vertebral height ratio of the injured vertebrae at 3 days and at internal fixation removal 1 year after the operation were compared between the two groups. Pedicle screw position accuracy was assessed according to Gertzbein criteria.</p><p><strong>Results: </strong>The operation times of the RA group and FH group were 138.69 ± 32.67 minutes and 103.67 ± 14.53 minutes, respectively, and the difference was statistically significant. The intraoperative blood loss was 49.23 ± 22.56 ml in the RA group and 78.33 ± 23.90 ml in the FH group, and the difference was statistically significant. There was a significant difference in the A/P vertebral height ratio of the injured vertebrae 3 days after the operation compared with before the operation in both groups (P < 0.05). There was a significant difference in the A/P vertebral height ratio of the injured vertebrae 3 days after the operation compared with that at fixation removal in both groups (P < 0.05).</p><p><strong>Conclusion: </strong>The application of RA orthopedic treatment for thoracolumbar fractures can achieve good fracture reduction.</p>","PeriodicalId":9109,"journal":{"name":"Bio-medical materials and engineering","volume":"34 4","pages":"375-383"},"PeriodicalIF":1.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bio-medical materials and engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/BME-222521","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: There are conflicting results for robot-assisted (RA) pedicle screw fixation compared with freehand (FH) pedicle screw fixation.

Objective: This study was designed to retrospectively compare the accuracy and efficacy of RA percutaneous pedicle screw fixation and traditional freehand FH pedicle screw fixation in the treatment of thoracolumbar fractures.

Methods: A total of 26 cases were assigned to the RA group, and 24 cases were assigned to the FH group. The operation time, bleeding volume, and visual analog scale (VAS) score 1 day after the operation, and the anterior/posterior (A/P) vertebral height ratio of the injured vertebrae at 3 days and at internal fixation removal 1 year after the operation were compared between the two groups. Pedicle screw position accuracy was assessed according to Gertzbein criteria.

Results: The operation times of the RA group and FH group were 138.69 ± 32.67 minutes and 103.67 ± 14.53 minutes, respectively, and the difference was statistically significant. The intraoperative blood loss was 49.23 ± 22.56 ml in the RA group and 78.33 ± 23.90 ml in the FH group, and the difference was statistically significant. There was a significant difference in the A/P vertebral height ratio of the injured vertebrae 3 days after the operation compared with before the operation in both groups (P < 0.05). There was a significant difference in the A/P vertebral height ratio of the injured vertebrae 3 days after the operation compared with that at fixation removal in both groups (P < 0.05).

Conclusion: The application of RA orthopedic treatment for thoracolumbar fractures can achieve good fracture reduction.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于1年随访观察的机器人辅助与传统手术治疗胸腰椎骨折的比较研究。
背景:机器人辅助(RA)椎弓根螺钉固定与徒手(FH)椎弓根螺钉固定的结果相互矛盾。目的:回顾性比较RA经皮椎弓根螺钉内固定与传统徒手FH椎弓根螺钉内固定治疗胸腰椎骨折的准确性和疗效。方法:将26例患者分为RA组,24例分为FH组。比较两组患者术后1天的手术时间、出血量、视觉模拟评分(VAS)评分,以及术后3天和1年内固定拆除时损伤椎体的前后椎体高度比。根据Gertzbein标准评估椎弓根螺钉定位精度。结果:RA组和FH组手术时间分别为138.69±32.67 min和103.67±14.53 min,差异有统计学意义。RA组术中出血量为49.23±22.56 ml, FH组为78.33±23.90 ml,差异有统计学意义。两组患者术后3 d损伤椎体a /P椎体高度比与术前比较差异均有统计学意义(P)。结论:应用RA骨科治疗胸腰椎骨折可达到较好的骨折复位效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Bio-medical materials and engineering
Bio-medical materials and engineering 工程技术-材料科学:生物材料
CiteScore
1.80
自引率
0.00%
发文量
73
审稿时长
6 months
期刊介绍: The aim of Bio-Medical Materials and Engineering is to promote the welfare of humans and to help them keep healthy. This international journal is an interdisciplinary journal that publishes original research papers, review articles and brief notes on materials and engineering for biological and medical systems. Articles in this peer-reviewed journal cover a wide range of topics, including, but not limited to: Engineering as applied to improving diagnosis, therapy, and prevention of disease and injury, and better substitutes for damaged or disabled human organs; Studies of biomaterial interactions with the human body, bio-compatibility, interfacial and interaction problems; Biomechanical behavior under biological and/or medical conditions; Mechanical and biological properties of membrane biomaterials; Cellular and tissue engineering, physiological, biophysical, biochemical bioengineering aspects; Implant failure fields and degradation of implants. Biomimetics engineering and materials including system analysis as supporter for aged people and as rehabilitation; Bioengineering and materials technology as applied to the decontamination against environmental problems; Biosensors, bioreactors, bioprocess instrumentation and control system; Application to food engineering; Standardization problems on biomaterials and related products; Assessment of reliability and safety of biomedical materials and man-machine systems; and Product liability of biomaterials and related products.
期刊最新文献
Extract from Falcaria vulgaris loaded with exosomes for the treatment of hypertension in pregnant mice: In vitro and In vivo investigations. Acupuncture navigation method integrated with augmented reality. Assessment of decellularization strategy and biocompatibility testing of full-thickness abdominal wall to produce a tissue-engineered graft. Effect of bioceramic inclusions on gel-cast aliphatic polymer membranes for bone tissue engineering applications: An in vitro study. Promotion of maturation in CDM3-induced embryonic stem cell-derived cardiomyocytes by palmitic acid.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1