Influence of fabrication method on the manufacturing accuracy and internal discrepancy of removable partial dentures: A systematic review and meta-analysis

IF 4.8 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthetic Dentistry Pub Date : 2025-03-01 DOI:10.1016/j.prosdent.2023.04.004
Rata Rokhshad DDS , Azita Mazaheri Tehrani DDS, MSD , Arash Zarbakhsh DDS, MSD , Marta Revilla-León DDS, MSD, PhD
{"title":"Influence of fabrication method on the manufacturing accuracy and internal discrepancy of removable partial dentures: A systematic review and meta-analysis","authors":"Rata Rokhshad DDS ,&nbsp;Azita Mazaheri Tehrani DDS, MSD ,&nbsp;Arash Zarbakhsh DDS, MSD ,&nbsp;Marta Revilla-León DDS, MSD, PhD","doi":"10.1016/j.prosdent.2023.04.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div>Removable partial dentures (RPDs) can be fabricated with conventional casting procedures or computer-aided design and computer-aided manufacturing (CAD-CAM) technologies; however, the manufacturing accuracy and internal discrepancy differences among these manufacturing methods remain uncertain.</div></div><div><h3>Purpose</h3><div>The purpose of this systematic review and meta-analysis was to assess the influence of the fabricating method (casting, milling, or additive manufacturing) on the accuracy and internal discrepancy of RPDs.</div></div><div><h3>Material and methods</h3><div>An electronic search of the literature was performed in 6 databases: PubMed/Medline, Embase, Web of Science, Scopus, Cochrane, and Google Scholar. The studies that assessed the accuracy and internal discrepancy of RPDs fabricated from casting, milling, and additive manufacturing were included. Studies reporting gaps (mean) and standard deviations were included in the meta-analysis. Publication bias was identified using funnel plot asymmetry and the Egger test.</div></div><div><h3>Results</h3><div><span>A total of 25 articles were included. The internal discrepancy of the additively manufactured RPDs ranged from 14.4 to 511 μm and from 7 to 419 μm in conventionally fabricated RPDs. For the milling method, 20 to 66 μm horizontal and 17 to 59 μm vertical discrepancies were reported. The Egger tests indicated no publication bias among the studies that were included in the meta-analysis. Four included studies resulted in more than the acceptable clinical gap (311 μm) for the CAD-CAM method. Independently of the manufacturing method, the greatest internal discrepancies reported were observed under the major connectors. RPDs fabricated by using CAD-CAM techniques required fewer clinical appointments, the RPD design was easier to reproduce, and laboratory time was less than with conventional procedures. However, the reviewed studies described several disadvantages, including limited RPD design programs, difficulties in defining the </span>occlusal plane, expensive materials, and increased laboratory cost.</div></div><div><h3>Conclusions</h3><div>Additive and subtractive technologies provide accurate methods for RPD fabrication; however, all challenges, including limited design software programs have not yet been overcome, and casting is still needed when the framework pattern is milled or printed.</div></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"133 3","pages":"Pages 724-735"},"PeriodicalIF":4.8000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391323002561","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem

Removable partial dentures (RPDs) can be fabricated with conventional casting procedures or computer-aided design and computer-aided manufacturing (CAD-CAM) technologies; however, the manufacturing accuracy and internal discrepancy differences among these manufacturing methods remain uncertain.

Purpose

The purpose of this systematic review and meta-analysis was to assess the influence of the fabricating method (casting, milling, or additive manufacturing) on the accuracy and internal discrepancy of RPDs.

Material and methods

An electronic search of the literature was performed in 6 databases: PubMed/Medline, Embase, Web of Science, Scopus, Cochrane, and Google Scholar. The studies that assessed the accuracy and internal discrepancy of RPDs fabricated from casting, milling, and additive manufacturing were included. Studies reporting gaps (mean) and standard deviations were included in the meta-analysis. Publication bias was identified using funnel plot asymmetry and the Egger test.

Results

A total of 25 articles were included. The internal discrepancy of the additively manufactured RPDs ranged from 14.4 to 511 μm and from 7 to 419 μm in conventionally fabricated RPDs. For the milling method, 20 to 66 μm horizontal and 17 to 59 μm vertical discrepancies were reported. The Egger tests indicated no publication bias among the studies that were included in the meta-analysis. Four included studies resulted in more than the acceptable clinical gap (311 μm) for the CAD-CAM method. Independently of the manufacturing method, the greatest internal discrepancies reported were observed under the major connectors. RPDs fabricated by using CAD-CAM techniques required fewer clinical appointments, the RPD design was easier to reproduce, and laboratory time was less than with conventional procedures. However, the reviewed studies described several disadvantages, including limited RPD design programs, difficulties in defining the occlusal plane, expensive materials, and increased laboratory cost.

Conclusions

Additive and subtractive technologies provide accurate methods for RPD fabrication; however, all challenges, including limited design software programs have not yet been overcome, and casting is still needed when the framework pattern is milled or printed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
制作方法对可摘局部义齿制作精度和内部差异的影响:一项系统回顾和荟萃分析
可摘局部义齿(rpd)可以用传统的铸造工艺或计算机辅助设计和计算机辅助制造(CAD-CAM)技术制造;然而,这些制造方法之间的制造精度和内部差异仍然不确定。本系统综述和荟萃分析的目的是评估制造方法(铸造、铣削或增材制造)对rpd精度和内部差异的影响。材料与方法在PubMed/Medline、Embase、Web of Science、Scopus、Cochrane和谷歌Scholar 6个数据库中进行文献电子检索。评估精度和内部差异的研究从铸造,铣削,和增材制造制造的rpd包括在内。报告差距(平均值)和标准偏差的研究纳入meta分析。采用漏斗图不对称和Egger检验确定发表偏倚。结果共纳入25篇文献。增材制备的rpd内部误差范围为14.4 ~ 511 μm,常规制备的rpd内部误差范围为7 ~ 419 μm。对于铣削方法,有20 ~ 66 μm的水平误差和17 ~ 59 μm的垂直误差。Egger检验表明纳入meta分析的研究中没有发表偏倚。四项纳入的研究结果超过了CAD-CAM方法可接受的临床间隙(311 μm)。与制造方法无关,在主要连接器下观察到最大的内部差异。使用CAD-CAM技术制作的RPD需要较少的临床预约,RPD设计更容易复制,并且与传统方法相比,实验室时间更短。然而,回顾的研究描述了一些缺点,包括有限的RPD设计方案,难以确定咬合平面,昂贵的材料和增加的实验室成本。结论加减法技术为RPD的制备提供了准确的方法;然而,所有的挑战,包括有限的设计软件程序还没有被克服,当框架模式被铣削或打印时,仍然需要铸造。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
期刊最新文献
Properties of 3D printed resins for definitive dental restorations: A systematic review. Intraoral scan versus cone beam computed tomography to assess implant position: A systematic review and meta-analysis. Mandibular cone beam-CT radiomorphometric indices for enhancing precision in predicting implant outcomes. Detection of periapical lesions in teeth with fixed prostheses using segmentation models and analyzing crown-lesion relationships. Impact of macrogeometry on the primary stability and bone markers of dental implants: A prospective, controlled, randomized, split-mouth clinical study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1