A Novel Plate for Vertical Shear Fractures of the Medial Malleolus: A Biomechanical Study.

IF 0.6 4区 医学 Q4 ORTHOPEDICS Journal of the American Podiatric Medical Association Pub Date : 2024-11-01 DOI:10.7547/22-100
Yunus Emre Bektas, Ramadan Özmanevra, Hakan Cici, Samet Ciklacandir, Nihat Demirhan Demirkiran, Yalcin Isler, Onur Basci, Mehmet Erduran
{"title":"A Novel Plate for Vertical Shear Fractures of the Medial Malleolus: A Biomechanical Study.","authors":"Yunus Emre Bektas, Ramadan Özmanevra, Hakan Cici, Samet Ciklacandir, Nihat Demirhan Demirkiran, Yalcin Isler, Onur Basci, Mehmet Erduran","doi":"10.7547/22-100","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to evaluate and compare stiffness and load to failure values of a novel medial malleolus compression plate (MP) and a 3.5-mm one-third tubular plate (TP) in the treatment of vertical shear fractures of the medial malleolus.</p><p><strong>Methods: </strong>Fourteen identical synthetic third-generation composite polyurethane bone models of the right distal tibia were randomly separated into two groups. Fracture models were created with a custom-made osteotomy guide to provide the same fracture characteristics in every sample (AO/OTA type 44A2). Fractures were reduced, and a novel MP was applied to bone models in the MP group and a TP was applied in the TP group. All of the samples were evaluated biomechanically, and force/displacement and load to failure values were recorded.</p><p><strong>Results: </strong>The force required to create displacement in the MP group was twice of that in the TP group. There was a significant difference between the two groups in all of the amounts of displacement (P = .006, P = .005, P = .007 and P = .015 for 0.5, 1.0, 1.5, and 2.0 mm, respectively).</p><p><strong>Conclusions: </strong>In the treatment of vertical shear fractures of the medial malleolus, the strength of fixation with the novel MP is biomechanically higher than that with the one-third semi-TP.</p>","PeriodicalId":17241,"journal":{"name":"Journal of the American Podiatric Medical Association","volume":" ","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Podiatric Medical Association","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.7547/22-100","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: This study aimed to evaluate and compare stiffness and load to failure values of a novel medial malleolus compression plate (MP) and a 3.5-mm one-third tubular plate (TP) in the treatment of vertical shear fractures of the medial malleolus.

Methods: Fourteen identical synthetic third-generation composite polyurethane bone models of the right distal tibia were randomly separated into two groups. Fracture models were created with a custom-made osteotomy guide to provide the same fracture characteristics in every sample (AO/OTA type 44A2). Fractures were reduced, and a novel MP was applied to bone models in the MP group and a TP was applied in the TP group. All of the samples were evaluated biomechanically, and force/displacement and load to failure values were recorded.

Results: The force required to create displacement in the MP group was twice of that in the TP group. There was a significant difference between the two groups in all of the amounts of displacement (P = .006, P = .005, P = .007 and P = .015 for 0.5, 1.0, 1.5, and 2.0 mm, respectively).

Conclusions: In the treatment of vertical shear fractures of the medial malleolus, the strength of fixation with the novel MP is biomechanically higher than that with the one-third semi-TP.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
内踝垂直剪切骨折的新型钢板:生物力学研究。
背景:本研究旨在评估和比较一种新型内踝加压钢板(MP)和3.5 mm三分之一管钢板(TP)治疗内踝垂直剪切骨折的刚度和载荷失效值。方法:选取14个相同的右侧胫骨远端合成第三代复合聚氨酯骨模型,随机分为两组。使用定制的截骨指南创建骨折模型,以提供每个样本相同的骨折特征(AO/OTA型44A2)。骨折复位,MP组骨模型应用新型MP, TP组骨模型应用TP。对所有样本进行生物力学评估,并记录力/位移和载荷到失效值。结果:MP组产生位移所需的力是TP组的2倍。两组之间的所有位移量均有显著差异(分别为0.5,1.0,1.5和2.0 mm, P = 0.006, P = 0.005, P = 0.007和P = 0.015)。结论:在治疗内踝垂直剪力骨折时,新型MP的生物力学固定强度高于三分之一半tp。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
128
审稿时长
6-12 weeks
期刊介绍: The Journal of the American Podiatric Medical Association, the official journal of the Association, is the oldest and most frequently cited peer-reviewed journal in the profession of foot and ankle medicine. Founded in 1907 and appearing 6 times per year, it publishes research studies, case reports, literature reviews, special communications, clinical correspondence, letters to the editor, book reviews, and various other types of submissions. The Journal is included in major indexing and abstracting services for biomedical literature.
期刊最新文献
Reliability of Radiologic Measurements in Children with Flexible Flat Feet. Body Mass and Foot Dominance Disparities in the Foot Plantar Pressure Parameters of Older Women. Comparing Self-Perceived Awareness with Actual Awareness of the Podiatric Medicine Profession Among High School and College Students. Correlation Between Plantar Fascia Thickness and Other Variables in Women Diagnosed With Plantar Fasciopathy. Intrafoot Coordination and Its Variability During Walking in Males with and Without Chronic Ankle Instability.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1