Comparative Study of Continuous Wavelet Transform and Multivariate Calibration for the Simultaneous Spectrophotometric Determination of Tamsulosin and Solifenacin in Pharmaceutical Formulation and Biological Sample.

IF 1.7 4区 农林科学 Q3 CHEMISTRY, ANALYTICAL Journal of AOAC International Pub Date : 2023-11-02 DOI:10.1093/jaoacint/qsad065
Nazanin Ashrafi, Mahmoud Reza Sohrabi, Mandana Saber Tehrani
{"title":"Comparative Study of Continuous Wavelet Transform and Multivariate Calibration for the Simultaneous Spectrophotometric Determination of Tamsulosin and Solifenacin in Pharmaceutical Formulation and Biological Sample.","authors":"Nazanin Ashrafi,&nbsp;Mahmoud Reza Sohrabi,&nbsp;Mandana Saber Tehrani","doi":"10.1093/jaoacint/qsad065","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Spectrophotometry alone is not applicable for the simultaneous determination of drugs in a multicomponent pharmaceutical formulation owing to their overlap.</p><p><strong>Objective: </strong>In this study, the combination of UV-Vis spectrophotometry and chemometric methods, including continuous wavelet transform (CWT) and partial least-squares (PLS) was presented for the simultaneous estimation of tamsulosin (TAM) and solifenacin (SOL) in synthetic mixtures, commercial formulations, and a biological sample.</p><p><strong>Methods: </strong>The simultaneous spectrophotometric determination of TAM and SOL in binary mixtures, a real sample, and a biological sample was performed by applying CWT and PLS approaches.</p><p><strong>Results: </strong>In the CWT method, two various wavelet families named Daubechies (db2) at wavelength 223 nm and Biorthogonal (bior1.3) at wavelength 227 nm based on the appropriate zero-crossing point were selected for TAM and SOL, respectively. The linear ranges of TAM and SOL were 0.25-4 μg/mL and 10-30 μg/mL, respectively. The LODs were 0.0459 μg/mL and 0.2085 μg/mL, while the LOQs were 0.3208 μg/mL and 0.6495 μg/mL for TAM and SOL, respectively. The average recovery values of 18 mixtures were 98.28% and 97.79% for TAM and SOL, respectively. Also, the root mean square error (RMSE) of both components was lower than 2.3. Based on the k-fold cross-validation in the PLS approach, the optimum number of components related to TAM and SOL were 9 and 5 with a mean square error prediction (MSEP) of 0.0153 and 0.0370, respectively. The mean recovery values of the test set were found to be 100.09% for TAM and 99.95% for SOL where RMSE values were 0.0064 and 0.0169 for TAM and SOL, respectively.</p><p><strong>Conclusion: </strong>Analysis of variance (ANOVA) was applied to the results of the real sample and there was no significant difference between the proposed methods and HPLC as a reference technique. The result obtained revealed that the proposed methods were found to be fast, facile, economical, and precise, and provide a suitable alternative to the HPLC technique for the concurrent determination of TAM and SOL in QC laboratories.</p><p><strong>Highlights: </strong>UV-Vis spectrophotometry combined with CWT and PLS was developed. Simultaneous analysis of TAM and SOL was performed using the proposed approaches. These methods were implemented on synthetic mixtures, commercial formulations, and a biological sample. ANOVA test was used to compare the suggested methods and the HPLC technique.</p>","PeriodicalId":15003,"journal":{"name":"Journal of AOAC International","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2023-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of AOAC International","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1093/jaoacint/qsad065","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Spectrophotometry alone is not applicable for the simultaneous determination of drugs in a multicomponent pharmaceutical formulation owing to their overlap.

Objective: In this study, the combination of UV-Vis spectrophotometry and chemometric methods, including continuous wavelet transform (CWT) and partial least-squares (PLS) was presented for the simultaneous estimation of tamsulosin (TAM) and solifenacin (SOL) in synthetic mixtures, commercial formulations, and a biological sample.

Methods: The simultaneous spectrophotometric determination of TAM and SOL in binary mixtures, a real sample, and a biological sample was performed by applying CWT and PLS approaches.

Results: In the CWT method, two various wavelet families named Daubechies (db2) at wavelength 223 nm and Biorthogonal (bior1.3) at wavelength 227 nm based on the appropriate zero-crossing point were selected for TAM and SOL, respectively. The linear ranges of TAM and SOL were 0.25-4 μg/mL and 10-30 μg/mL, respectively. The LODs were 0.0459 μg/mL and 0.2085 μg/mL, while the LOQs were 0.3208 μg/mL and 0.6495 μg/mL for TAM and SOL, respectively. The average recovery values of 18 mixtures were 98.28% and 97.79% for TAM and SOL, respectively. Also, the root mean square error (RMSE) of both components was lower than 2.3. Based on the k-fold cross-validation in the PLS approach, the optimum number of components related to TAM and SOL were 9 and 5 with a mean square error prediction (MSEP) of 0.0153 and 0.0370, respectively. The mean recovery values of the test set were found to be 100.09% for TAM and 99.95% for SOL where RMSE values were 0.0064 and 0.0169 for TAM and SOL, respectively.

Conclusion: Analysis of variance (ANOVA) was applied to the results of the real sample and there was no significant difference between the proposed methods and HPLC as a reference technique. The result obtained revealed that the proposed methods were found to be fast, facile, economical, and precise, and provide a suitable alternative to the HPLC technique for the concurrent determination of TAM and SOL in QC laboratories.

Highlights: UV-Vis spectrophotometry combined with CWT and PLS was developed. Simultaneous analysis of TAM and SOL was performed using the proposed approaches. These methods were implemented on synthetic mixtures, commercial formulations, and a biological sample. ANOVA test was used to compare the suggested methods and the HPLC technique.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
连续小波变换与多元校正同时分光光度法测定制剂和生物样品中坦索罗辛和索利那新的比较研究。
背景:单独的分光光度法不适用于同时测定多组分药物制剂中的药物,因为它们有重叠。目的:本研究采用紫外-可见分光光度法和化学计量方法,包括连续小波变换(CWT)和偏最小二乘法(PLS),同时测定合成混合物、商业制剂和生物样品中坦洛新(TAM)和索非那新(SOL)的含量。方法:采用CWT法和PLS法同时测定二元混合物、真实样品和生物样品中的TAM和SOL。结果:在CWT方法中,两个不同的小波族在波长223处被命名为Daubechies(db2) nm和波长227的双正交(bior1.3) 基于适当的过零点分别为TAM和SOL选择nm。TAM和SOL的线性范围为0.25-4 μg/mL和10-30 μg/mL。LOD为0.0459 μg/mL和0.2085 μg/mL,而LOQ为0.3208 μg/mL和0.6495 TAM和SOL分别为μg/mL。18种混合物对TAM和SOL的平均回收率分别为98.28%和97.79%。两组分的均方根误差均小于2.3。基于PLS方法中的k倍交叉验证,与TAM和SOL相关的最佳成分数量分别为9和5,均方误差预测(MSEP)分别为0.0153和0.0370。试验组的平均回收率TAM为100.09%,SOL为99.95%,其中TAM和SOL的RMSE值分别为0.0064和0.0169。结论:将方差分析(ANOVA)应用于真实样本的结果,所提出的方法与作为参考技术的HPLC之间没有显著差异。结果表明,所提出的方法快速、简便、经济、准确,为QC实验室同时测定TAM和SOL提供了一种合适的替代HPLC技术的方法。亮点:紫外-可见分光光度法与CWT和PLS相结合。使用所提出的方法同时分析TAM和SOL。这些方法在合成混合物、商业制剂和生物样品上实施。采用方差分析法对所提出的方法与高效液相色谱法进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of AOAC International
Journal of AOAC International 医学-分析化学
CiteScore
3.10
自引率
12.50%
发文量
144
审稿时长
2.7 months
期刊介绍: The Journal of AOAC INTERNATIONAL publishes the latest in basic and applied research in analytical sciences related to foods, drugs, agriculture, the environment, and more. The Journal is the method researchers'' forum for exchanging information and keeping informed of new technology and techniques pertinent to regulatory agencies and regulated industries.
期刊最新文献
Bacterial Inactivation Studies in Shrimp Pond Water by using Different Disinfectant Agents Ivermectin-based products in the context of green pharmaceutical analysis Comparison of Roka Atlas® System Performance and Health Canada Reference Method for Listeria Detection from Plastic, Sealed Concrete, and Stainless Steel Surface Samples Determination of Aloin A, Aloin B, and Aloe-Emodin in Raw Materials and Finished Products Using HPLC Multi-Laboratory Validation Study, AOAC 2016.09, Final Action Status Determination of Toxic Elements in Botanical Dietary Supplement Ingredient Reference Materials
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1