William V. McCall, Jessica T. Dinsmore, Alicia Brown, Lucas T. Ribbens, Peter B. Rosenquist, Laryssa McCloud, Brian J. Miller
{"title":"Reproducibility of the pupillary light reflex over short intervals in psychiatric patients and community volunteers","authors":"William V. McCall, Jessica T. Dinsmore, Alicia Brown, Lucas T. Ribbens, Peter B. Rosenquist, Laryssa McCloud, Brian J. Miller","doi":"10.1111/cpf.12834","DOIUrl":null,"url":null,"abstract":"<p>The pupillary light reflex (PLR) is a method for measuring dynamic responses within the autonomic nervous system, and would have potential value as a point-of-care test in a psychiatry clinic if reproducible results could be obtained in a short period of time. We collected PLR from adult community volunteers and depressed outpatients with the purpose of demonstrating (1) that valid data could be obtained >90% of the time from both the community volunteers and the patients, and (2) that reproducible results could be obtained with repeated measurement over short periods of time. Valid data were captured for 90.3% of 76 participants, allowing for two attempts of the PLR per participant. Success rates were similar for depressed patients and community volunteers. Eighteen of these 76 participants provided repeated paired measurements after 5 and 10 min of dark adaptation, producing high correlations for maximum constriction velocity (MCV) between assay 1 and 2 (Pearson's <i>r</i> = 0.71, <i>p</i> < 0.001), but there was a significant 8% increase in velocity for MCV between assay 1 and 2 (∆ = 0.34 ± 0.59 mm/s, <i>p</i> < 0.05). In contrast, PLR measurements were stable when tested in a separate cohort of 21 additional participants at 10 and 15 min of dark adaptation with an MCV Pearson's correlation of <i>r</i> = 0.84, <i>p</i> < 0.001, with a nonsignificant 1% difference between the two time points. These findings indicate an acceptable rate of collecting valid and reproducible PLR data when contrasting two measurements of PLR after 10 or 15 min of dark adaptation in depressed and suicidal patients.</p>","PeriodicalId":10504,"journal":{"name":"Clinical Physiology and Functional Imaging","volume":"43 5","pages":"365-372"},"PeriodicalIF":1.3000,"publicationDate":"2023-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Physiology and Functional Imaging","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cpf.12834","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
The pupillary light reflex (PLR) is a method for measuring dynamic responses within the autonomic nervous system, and would have potential value as a point-of-care test in a psychiatry clinic if reproducible results could be obtained in a short period of time. We collected PLR from adult community volunteers and depressed outpatients with the purpose of demonstrating (1) that valid data could be obtained >90% of the time from both the community volunteers and the patients, and (2) that reproducible results could be obtained with repeated measurement over short periods of time. Valid data were captured for 90.3% of 76 participants, allowing for two attempts of the PLR per participant. Success rates were similar for depressed patients and community volunteers. Eighteen of these 76 participants provided repeated paired measurements after 5 and 10 min of dark adaptation, producing high correlations for maximum constriction velocity (MCV) between assay 1 and 2 (Pearson's r = 0.71, p < 0.001), but there was a significant 8% increase in velocity for MCV between assay 1 and 2 (∆ = 0.34 ± 0.59 mm/s, p < 0.05). In contrast, PLR measurements were stable when tested in a separate cohort of 21 additional participants at 10 and 15 min of dark adaptation with an MCV Pearson's correlation of r = 0.84, p < 0.001, with a nonsignificant 1% difference between the two time points. These findings indicate an acceptable rate of collecting valid and reproducible PLR data when contrasting two measurements of PLR after 10 or 15 min of dark adaptation in depressed and suicidal patients.
期刊介绍:
Clinical Physiology and Functional Imaging publishes reports on clinical and experimental research pertinent to human physiology in health and disease. The scope of the Journal is very broad, covering all aspects of the regulatory system in the cardiovascular, renal and pulmonary systems with special emphasis on methodological aspects. The focus for the journal is, however, work that has potential clinical relevance. The Journal also features review articles on recent front-line research within these fields of interest.
Covered by the major abstracting services including Current Contents and Science Citation Index, Clinical Physiology and Functional Imaging plays an important role in providing effective and productive communication among clinical physiologists world-wide.