Phoebe Burrer, Shpresa Simoni, Paula Zwicky, Thomas Attin, Tobias T Tauböck
{"title":"不同粘接方式对过度蚀刻牙本质粘接强度的影响。","authors":"Phoebe Burrer, Shpresa Simoni, Paula Zwicky, Thomas Attin, Tobias T Tauböck","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the effect of over-etching and subsequent use of different adhesive application approaches including active, double, preheated, and ultrasonic application on dentin bond strength.</p><p><strong>Methods: </strong>Dentin specimens from sound human third molars were prepared and allocated into six groups (n= 10 per group). In Group 1 (negative control), the dentin specimens were over-etched with phosphoric acid for 30 seconds, and a two-step etch-and-rinse adhesive (Prime & Bond XP; Dentsply Sirona) was applied for 20 seconds according to the manufacturer's instructions. In test Groups 2-5, the application of the adhesive varied: In Group 2, the adhesive was actively rubbed into the dentin surface, whereas in Group 3, a second adhesive layer was applied after light-curing of the first one. In Group 4, the adhesive was heated to 68°C prior to application, and in Group 5, the adhesive was ultrasonically activated. Acid-etching for 15 seconds and adhesive application for 20 seconds was performed in the positive control group (Group 6) according to the manufacturer's instructions. After light-curing and composite build-up [Ceram.x Spectra ST (HV); Dentsply Sirona], microtensile bond strength and fracture types were determined. Data were statistically analyzed by Kruskal-Wallis rank test, followed by post-hoc pairwise comparisons using Conover tests and P-value adjustment according to Holm (α= 0.05).</p><p><strong>Results: </strong>Active, double, preheated, or ultrasonic adhesive application showed no significant effect on dentin bond strength when compared to the control groups. Predominantly adhesive failures were observed in all groups.</p><p><strong>Clinical significance: </strong>A modification of adhesive application by using active, double, preheated, or ultrasonic application does not improve bonding to accidentally over-etched dentin.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"36 3","pages":"118-122"},"PeriodicalIF":0.9000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of different adhesive application approaches on bond strength in over-etched dentin.\",\"authors\":\"Phoebe Burrer, Shpresa Simoni, Paula Zwicky, Thomas Attin, Tobias T Tauböck\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To investigate the effect of over-etching and subsequent use of different adhesive application approaches including active, double, preheated, and ultrasonic application on dentin bond strength.</p><p><strong>Methods: </strong>Dentin specimens from sound human third molars were prepared and allocated into six groups (n= 10 per group). In Group 1 (negative control), the dentin specimens were over-etched with phosphoric acid for 30 seconds, and a two-step etch-and-rinse adhesive (Prime & Bond XP; Dentsply Sirona) was applied for 20 seconds according to the manufacturer's instructions. In test Groups 2-5, the application of the adhesive varied: In Group 2, the adhesive was actively rubbed into the dentin surface, whereas in Group 3, a second adhesive layer was applied after light-curing of the first one. In Group 4, the adhesive was heated to 68°C prior to application, and in Group 5, the adhesive was ultrasonically activated. Acid-etching for 15 seconds and adhesive application for 20 seconds was performed in the positive control group (Group 6) according to the manufacturer's instructions. After light-curing and composite build-up [Ceram.x Spectra ST (HV); Dentsply Sirona], microtensile bond strength and fracture types were determined. Data were statistically analyzed by Kruskal-Wallis rank test, followed by post-hoc pairwise comparisons using Conover tests and P-value adjustment according to Holm (α= 0.05).</p><p><strong>Results: </strong>Active, double, preheated, or ultrasonic adhesive application showed no significant effect on dentin bond strength when compared to the control groups. Predominantly adhesive failures were observed in all groups.</p><p><strong>Clinical significance: </strong>A modification of adhesive application by using active, double, preheated, or ultrasonic application does not improve bonding to accidentally over-etched dentin.</p>\",\"PeriodicalId\":7538,\"journal\":{\"name\":\"American journal of dentistry\",\"volume\":\"36 3\",\"pages\":\"118-122\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of dentistry","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
目的:探讨过度蚀刻及后续使用不同的粘接方法,包括主动、双重、预热、超声等对牙本质粘接强度的影响。方法:制备健全人第三磨牙的牙本质标本,分为6组,每组10例。在第1组(阴性对照)中,牙本质标本用磷酸过度蚀刻30秒,并使用两步蚀刻-冲洗粘合剂(Prime & Bond XP;根据制造商的说明,应用Dentsply Sirona) 20秒。在测试组2-5中,胶粘剂的涂抹方式不同:第2组是主动将胶粘剂摩擦到牙本质表面,第3组是在第1层光固化后再涂抹第2层胶粘剂。第4组使用前将胶粘剂加热至68℃,第5组使用超声激活胶粘剂。阳性对照组(第6组)按照制造商的说明书进行酸蚀15秒,涂胶20秒。经过光固化和复合构筑[陶瓷]。x Spectra ST (HV);Dentsply Sirona],测定微拉伸粘结强度和断裂类型。数据采用Kruskal-Wallis秩检验进行统计学分析,采用Conover检验进行事后两两比较,并根据Holm进行p值调整(α= 0.05)。结果:与对照组相比,使用活性、双重、预热或超声黏合剂对牙本质黏结强度无显著影响。所有组中主要观察到粘附失败。临床意义:通过使用主动、双重、预热或超声等方法来改进粘接剂的应用,并不能改善意外过度蚀刻牙本质的粘接性。
Effect of different adhesive application approaches on bond strength in over-etched dentin.
Purpose: To investigate the effect of over-etching and subsequent use of different adhesive application approaches including active, double, preheated, and ultrasonic application on dentin bond strength.
Methods: Dentin specimens from sound human third molars were prepared and allocated into six groups (n= 10 per group). In Group 1 (negative control), the dentin specimens were over-etched with phosphoric acid for 30 seconds, and a two-step etch-and-rinse adhesive (Prime & Bond XP; Dentsply Sirona) was applied for 20 seconds according to the manufacturer's instructions. In test Groups 2-5, the application of the adhesive varied: In Group 2, the adhesive was actively rubbed into the dentin surface, whereas in Group 3, a second adhesive layer was applied after light-curing of the first one. In Group 4, the adhesive was heated to 68°C prior to application, and in Group 5, the adhesive was ultrasonically activated. Acid-etching for 15 seconds and adhesive application for 20 seconds was performed in the positive control group (Group 6) according to the manufacturer's instructions. After light-curing and composite build-up [Ceram.x Spectra ST (HV); Dentsply Sirona], microtensile bond strength and fracture types were determined. Data were statistically analyzed by Kruskal-Wallis rank test, followed by post-hoc pairwise comparisons using Conover tests and P-value adjustment according to Holm (α= 0.05).
Results: Active, double, preheated, or ultrasonic adhesive application showed no significant effect on dentin bond strength when compared to the control groups. Predominantly adhesive failures were observed in all groups.
Clinical significance: A modification of adhesive application by using active, double, preheated, or ultrasonic application does not improve bonding to accidentally over-etched dentin.
期刊介绍:
The American Journal of Dentistry, published by Mosher & Linder, Inc., provides peer-reviewed scientific articles with clinical significance for the general dental practitioner.