侧射Er,Cr:YSGG激光对钛盘表面去污效果的体内外研究

IF 3.1 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Implant Dentistry Pub Date : 2023-02-20 DOI:10.1186/s40729-023-00469-z
Lucia Kottmann, Rene Franzen, Georg Conrads, Stefan Wolfart, Juliana Marotti
{"title":"侧射Er,Cr:YSGG激光对钛盘表面去污效果的体内外研究","authors":"Lucia Kottmann,&nbsp;Rene Franzen,&nbsp;Georg Conrads,&nbsp;Stefan Wolfart,&nbsp;Juliana Marotti","doi":"10.1186/s40729-023-00469-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effectiveness of an erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser with side-firing tip in decontamination of titanium (Ti) disc.</p><p><strong>Methods: </strong>In the first test series, 29 Ti-discs were contaminated with Staphylococcus aureus and treated as follows: positive control (no treatment); Perioflow; Laser A (0.75 W, 100 Hz), Laser B (1.5 W, 30 Hz); Laser C (no radiation, 60% water); and Laser D (no radiation, 50% water). For bacterial quantification, colony forming units (CFU, vital cells only) and quantitative PCR (qPCR, vital and devital cells) were performed. In a second test series, 92 Ti-discs were used, contaminated with in vivo-grown biofilm and treated as follows: positive control (no treatment); Perioflow; Laser E (1.5 W, 30 Hz), and Laser F (no radiation, 50% water). Considering the different and unknown culture conditions, quantification of bacteria was performed by broad-spectrum bacterial qPCR only. Based on the assumption that all cells of an organism contain an equivalent complement of genetic information, genome equivalent (GE) determination ensured the detection of the different intact and semi-intact genomes, regardless of type of bacterial species and vitality, circumvent the inherent bias of cultures.</p><p><strong>Results: </strong>The GE values were significantly reduced by all interventions in both test series, compared to the positive control group (p < 0.001). In the first test series with S. aureus as model organism, Perioflow yielded a lower GE than the Laser groups A-D (all p < 0.025). The number of CFUs was significantly reduced in the intervention groups compared to the positive control (p < 0.001), except for Laser A (p = 0.157) and Laser D (p = 0.393). In the second test series, none of the pairwise comparisons of the intervention conditions showed a significant difference (Perioflow vs. Laser E: p = 0.732; Perioflow vs. Laser F: p = 0.590; Laser E vs. Laser F: p = 0.379).</p><p><strong>Conclusion: </strong>The Er,Cr:YSGG laser with side-firing tip and Perioflow were equally capable of effectively decontaminating a Ti-disc surface. It is assumed that the bacterial reduction was largely due to the mechanical effect of the air and water stream.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2023-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10110821/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of Er,Cr:YSGG laser with a side-firing tip on decontamination of titanium disc surface: an in vitro and in vivo study.\",\"authors\":\"Lucia Kottmann,&nbsp;Rene Franzen,&nbsp;Georg Conrads,&nbsp;Stefan Wolfart,&nbsp;Juliana Marotti\",\"doi\":\"10.1186/s40729-023-00469-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the effectiveness of an erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser with side-firing tip in decontamination of titanium (Ti) disc.</p><p><strong>Methods: </strong>In the first test series, 29 Ti-discs were contaminated with Staphylococcus aureus and treated as follows: positive control (no treatment); Perioflow; Laser A (0.75 W, 100 Hz), Laser B (1.5 W, 30 Hz); Laser C (no radiation, 60% water); and Laser D (no radiation, 50% water). For bacterial quantification, colony forming units (CFU, vital cells only) and quantitative PCR (qPCR, vital and devital cells) were performed. In a second test series, 92 Ti-discs were used, contaminated with in vivo-grown biofilm and treated as follows: positive control (no treatment); Perioflow; Laser E (1.5 W, 30 Hz), and Laser F (no radiation, 50% water). Considering the different and unknown culture conditions, quantification of bacteria was performed by broad-spectrum bacterial qPCR only. Based on the assumption that all cells of an organism contain an equivalent complement of genetic information, genome equivalent (GE) determination ensured the detection of the different intact and semi-intact genomes, regardless of type of bacterial species and vitality, circumvent the inherent bias of cultures.</p><p><strong>Results: </strong>The GE values were significantly reduced by all interventions in both test series, compared to the positive control group (p < 0.001). In the first test series with S. aureus as model organism, Perioflow yielded a lower GE than the Laser groups A-D (all p < 0.025). The number of CFUs was significantly reduced in the intervention groups compared to the positive control (p < 0.001), except for Laser A (p = 0.157) and Laser D (p = 0.393). In the second test series, none of the pairwise comparisons of the intervention conditions showed a significant difference (Perioflow vs. Laser E: p = 0.732; Perioflow vs. Laser F: p = 0.590; Laser E vs. Laser F: p = 0.379).</p><p><strong>Conclusion: </strong>The Er,Cr:YSGG laser with side-firing tip and Perioflow were equally capable of effectively decontaminating a Ti-disc surface. It is assumed that the bacterial reduction was largely due to the mechanical effect of the air and water stream.</p>\",\"PeriodicalId\":14076,\"journal\":{\"name\":\"International Journal of Implant Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2023-02-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10110821/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Implant Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40729-023-00469-z\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-023-00469-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价铒、铬、钇、钪、镓、石榴石(Er,Cr:YSGG)侧射激光器对钛(Ti)圆盘净化的效果。方法:在第一个试验系列中,29个ti -disc被金黄色葡萄球菌污染,并进行如下处理:阳性对照(未处理);Perioflow;激光器A (0.75 W, 100 Hz),激光器B (1.5 W, 30 Hz);激光C(无辐射,60%水);激光D(无辐射,50%水)。对于细菌的定量,采用菌落形成单位(CFU,仅限重要细胞)和定量PCR (qPCR,重要细胞和重要细胞)。在第二个试验系列中,使用92个ti -disc,被体内生长的生物膜污染,并进行如下处理:阳性对照(未处理);Perioflow;E激光器(1.5 W, 30hz)和F激光器(无辐射,50%水)。考虑到不同和未知的培养条件,仅采用广谱细菌qPCR进行细菌定量。基于一个生物体的所有细胞都含有相同的遗传信息的假设,基因组当量(GE)测定确保了不同的完整和半完整基因组的检测,而不考虑细菌种类和活力的类型,从而规避了培养物固有的偏见。结果:与阳性对照组相比,在两个测试系列中,所有干预措施均显著降低了GE值(p)。结论:Er,Cr:YSGG激光具有侧射尖端和Perioflow的有效去污钛盘表面的能力相同。据推测,细菌的减少主要是由于空气和水流的机械作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Er,Cr:YSGG laser with a side-firing tip on decontamination of titanium disc surface: an in vitro and in vivo study.

Purpose: To evaluate the effectiveness of an erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser with side-firing tip in decontamination of titanium (Ti) disc.

Methods: In the first test series, 29 Ti-discs were contaminated with Staphylococcus aureus and treated as follows: positive control (no treatment); Perioflow; Laser A (0.75 W, 100 Hz), Laser B (1.5 W, 30 Hz); Laser C (no radiation, 60% water); and Laser D (no radiation, 50% water). For bacterial quantification, colony forming units (CFU, vital cells only) and quantitative PCR (qPCR, vital and devital cells) were performed. In a second test series, 92 Ti-discs were used, contaminated with in vivo-grown biofilm and treated as follows: positive control (no treatment); Perioflow; Laser E (1.5 W, 30 Hz), and Laser F (no radiation, 50% water). Considering the different and unknown culture conditions, quantification of bacteria was performed by broad-spectrum bacterial qPCR only. Based on the assumption that all cells of an organism contain an equivalent complement of genetic information, genome equivalent (GE) determination ensured the detection of the different intact and semi-intact genomes, regardless of type of bacterial species and vitality, circumvent the inherent bias of cultures.

Results: The GE values were significantly reduced by all interventions in both test series, compared to the positive control group (p < 0.001). In the first test series with S. aureus as model organism, Perioflow yielded a lower GE than the Laser groups A-D (all p < 0.025). The number of CFUs was significantly reduced in the intervention groups compared to the positive control (p < 0.001), except for Laser A (p = 0.157) and Laser D (p = 0.393). In the second test series, none of the pairwise comparisons of the intervention conditions showed a significant difference (Perioflow vs. Laser E: p = 0.732; Perioflow vs. Laser F: p = 0.590; Laser E vs. Laser F: p = 0.379).

Conclusion: The Er,Cr:YSGG laser with side-firing tip and Perioflow were equally capable of effectively decontaminating a Ti-disc surface. It is assumed that the bacterial reduction was largely due to the mechanical effect of the air and water stream.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
期刊最新文献
Effect of osteopenia and osteoporosis on failure of first and second dental implants: a retrospective observational study. Influence of gingival phenotype on crestal bone loss at implants : A long-term 2 to 20-year cohort study in periodontally compromised patient. An eight-year retrospective study on the clinical outcomes of laser surface-treated implants. Long-term follow-up of a patient with Parkinson's disease under nursing care after replacement of fixed implant-supported prostheses with an implant overdenture: a case report. Accuracy of computer-guided implant surgery in partially edentulous patients: a prospective observational study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1