Mitri K Khoury, Elizabeth Lancaster, Matthew J Eagleton, Warren J Gasper
{"title":"美国主动脉研究联合会的T型分支使用更新。","authors":"Mitri K Khoury, Elizabeth Lancaster, Matthew J Eagleton, Warren J Gasper","doi":"10.23736/S0021-9509.23.12737-6","DOIUrl":null,"url":null,"abstract":"<p><p>Aortic endograft evolution has altered our approach to treating patients with both standard and complex aortic disease. In particular, fenestrated and branched aortic endografts have allowed for the expansion of therapy to include those patients with extensive thoracoabdominal aortic aneurysms (TAAAs). The fenestrations and branches allow for the aortic endografts to achieve a seal in the proximal and distal aspects of the aorto-iliac tree, to exclude the aneurysm, while maintaining perfusion to the renal and visceral vessels. Historically, many of the grafts used for this purpose are custom made devices designed for a specific patient based on their preoperative computed tomography imaging. One downside to this approach is the time it takes to construct these grafts. Given this, much effort has been directed towards developing \"off-the-shelf\" grafts which may be applicable to many patients in an immediate-need bases. The Zenith T-Branch device offers an off-the-shelf graft with four directional branches. Its utilization is not applicable to all patients, but can be applied to many patients with TAAAs. Large reported series on outcomes for these devices is limited to centers in Europe as well as within the United States Aortic Research Consortium. While early outcomes appear excellent, long-term outcomes related to aneurysm exclusion, branch patency, and freedom from reintervention are needed and will be forthcoming.</p>","PeriodicalId":50245,"journal":{"name":"Journal of Cardiovascular Surgery","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Update of T-branch use from the US Aortic Research Consortium.\",\"authors\":\"Mitri K Khoury, Elizabeth Lancaster, Matthew J Eagleton, Warren J Gasper\",\"doi\":\"10.23736/S0021-9509.23.12737-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Aortic endograft evolution has altered our approach to treating patients with both standard and complex aortic disease. In particular, fenestrated and branched aortic endografts have allowed for the expansion of therapy to include those patients with extensive thoracoabdominal aortic aneurysms (TAAAs). The fenestrations and branches allow for the aortic endografts to achieve a seal in the proximal and distal aspects of the aorto-iliac tree, to exclude the aneurysm, while maintaining perfusion to the renal and visceral vessels. Historically, many of the grafts used for this purpose are custom made devices designed for a specific patient based on their preoperative computed tomography imaging. One downside to this approach is the time it takes to construct these grafts. Given this, much effort has been directed towards developing \\\"off-the-shelf\\\" grafts which may be applicable to many patients in an immediate-need bases. The Zenith T-Branch device offers an off-the-shelf graft with four directional branches. Its utilization is not applicable to all patients, but can be applied to many patients with TAAAs. Large reported series on outcomes for these devices is limited to centers in Europe as well as within the United States Aortic Research Consortium. While early outcomes appear excellent, long-term outcomes related to aneurysm exclusion, branch patency, and freedom from reintervention are needed and will be forthcoming.</p>\",\"PeriodicalId\":50245,\"journal\":{\"name\":\"Journal of Cardiovascular Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.23736/S0021-9509.23.12737-6\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/6/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S0021-9509.23.12737-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/30 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Update of T-branch use from the US Aortic Research Consortium.
Aortic endograft evolution has altered our approach to treating patients with both standard and complex aortic disease. In particular, fenestrated and branched aortic endografts have allowed for the expansion of therapy to include those patients with extensive thoracoabdominal aortic aneurysms (TAAAs). The fenestrations and branches allow for the aortic endografts to achieve a seal in the proximal and distal aspects of the aorto-iliac tree, to exclude the aneurysm, while maintaining perfusion to the renal and visceral vessels. Historically, many of the grafts used for this purpose are custom made devices designed for a specific patient based on their preoperative computed tomography imaging. One downside to this approach is the time it takes to construct these grafts. Given this, much effort has been directed towards developing "off-the-shelf" grafts which may be applicable to many patients in an immediate-need bases. The Zenith T-Branch device offers an off-the-shelf graft with four directional branches. Its utilization is not applicable to all patients, but can be applied to many patients with TAAAs. Large reported series on outcomes for these devices is limited to centers in Europe as well as within the United States Aortic Research Consortium. While early outcomes appear excellent, long-term outcomes related to aneurysm exclusion, branch patency, and freedom from reintervention are needed and will be forthcoming.
期刊介绍:
The Journal of Cardiovascular Surgery publishes scientific papers on cardiac, thoracic and vascular surgery. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, therapeutical notes, special articles and letters to the Editor.
Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (www.icmje.org). Articles not conforming to international standards will not be considered for acceptance.