两种不同修复材料冠的边缘间隙和图像质量评估:一项使用CBCT图像的体外研究。

Paulo Victor Teixeira Doriguêtto, Daniela de Almeida, Carolina Oliveira de Lima, Ricardo Tadeu Lopes, Karina Lopes Devito
{"title":"两种不同修复材料冠的边缘间隙和图像质量评估:一项使用CBCT图像的体外研究。","authors":"Paulo Victor Teixeira Doriguêtto,&nbsp;Daniela de Almeida,&nbsp;Carolina Oliveira de Lima,&nbsp;Ricardo Tadeu Lopes,&nbsp;Karina Lopes Devito","doi":"10.34172/joddd.2022.039","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The present study assessed the quality of images and the presence of marginal gaps on cone-beam computed tomography (CBCT) images of teeth restored with all-ceramic and metal-ceramic crowns and compared the gap sizes observed on CBCT images with those obtained on micro-CT images.</p><p><strong>Methods: </strong>Thirty teeth restored with metal-ceramic and all-ceramic crowns, properly adapted and with gaps of 0.30 and 0.50 mm, were submitted to micro-CT and CBCT scans. Linear measurements corresponding to the marginal gap (MG) and the absolute marginal discrepancy (AMD) were obtained. The objective assessment of the quality of CBCT images was performed using the contrast-to-noise ratio (CNR), and the subjective assessment was defined by the diagnoses made by five examiners regarding the presence or absence of gaps.</p><p><strong>Results: </strong>The measurements were always higher for CBCT, with a significant difference regarding AMD. No significant difference in image quality was observed using CNR between the crowns tested. Low accuracy and sensitivity values could be observed for both crowns.</p><p><strong>Conclusion: </strong>Marginal mismatch measures were overestimated in CBCT images. No difference in image quality was observed between the crowns. The correct diagnosis of gaps was considered low, irrespective of crown type and gap size.</p>","PeriodicalId":15599,"journal":{"name":"Journal of Dental Research, Dental Clinics, Dental Prospects","volume":"16 4","pages":"243-250"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10407872/pdf/","citationCount":"0","resultStr":"{\"title\":\"Assessment of marginal gaps and image quality of crowns made of two different restorative materials: An in vitro study using CBCT images.\",\"authors\":\"Paulo Victor Teixeira Doriguêtto,&nbsp;Daniela de Almeida,&nbsp;Carolina Oliveira de Lima,&nbsp;Ricardo Tadeu Lopes,&nbsp;Karina Lopes Devito\",\"doi\":\"10.34172/joddd.2022.039\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The present study assessed the quality of images and the presence of marginal gaps on cone-beam computed tomography (CBCT) images of teeth restored with all-ceramic and metal-ceramic crowns and compared the gap sizes observed on CBCT images with those obtained on micro-CT images.</p><p><strong>Methods: </strong>Thirty teeth restored with metal-ceramic and all-ceramic crowns, properly adapted and with gaps of 0.30 and 0.50 mm, were submitted to micro-CT and CBCT scans. Linear measurements corresponding to the marginal gap (MG) and the absolute marginal discrepancy (AMD) were obtained. The objective assessment of the quality of CBCT images was performed using the contrast-to-noise ratio (CNR), and the subjective assessment was defined by the diagnoses made by five examiners regarding the presence or absence of gaps.</p><p><strong>Results: </strong>The measurements were always higher for CBCT, with a significant difference regarding AMD. No significant difference in image quality was observed using CNR between the crowns tested. Low accuracy and sensitivity values could be observed for both crowns.</p><p><strong>Conclusion: </strong>Marginal mismatch measures were overestimated in CBCT images. No difference in image quality was observed between the crowns. The correct diagnosis of gaps was considered low, irrespective of crown type and gap size.</p>\",\"PeriodicalId\":15599,\"journal\":{\"name\":\"Journal of Dental Research, Dental Clinics, Dental Prospects\",\"volume\":\"16 4\",\"pages\":\"243-250\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10407872/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Dental Research, Dental Clinics, Dental Prospects\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.34172/joddd.2022.039\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Research, Dental Clinics, Dental Prospects","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/joddd.2022.039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

背景:本研究评估了全陶瓷和金属陶瓷冠修复牙齿的锥形束计算机断层扫描(CBCT)图像质量和边缘间隙的存在,并将CBCT图像与微ct图像观察到的间隙大小进行了比较。方法:采用金属陶瓷冠和全陶瓷冠修复牙体30颗,修复牙体间隙分别为0.30和0.50 mm,进行微ct和CBCT扫描。得到了相应的边际间隙(MG)和绝对边际差异(AMD)的线性测量值。CBCT图像质量的客观评价采用噪声对比比(CNR),主观评价由五名检查人员对有无间隙的诊断来确定。结果:CBCT的测量值总是更高,在AMD方面有显著差异。不同冠间的图像质量无显著差异。两种冠的准确度和灵敏度均较低。结论:CBCT图像的边缘失配测量值被高估。冠间图像质量无差异。无论冠型和牙隙大小如何,牙隙的正确诊断被认为是低的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of marginal gaps and image quality of crowns made of two different restorative materials: An in vitro study using CBCT images.

Background: The present study assessed the quality of images and the presence of marginal gaps on cone-beam computed tomography (CBCT) images of teeth restored with all-ceramic and metal-ceramic crowns and compared the gap sizes observed on CBCT images with those obtained on micro-CT images.

Methods: Thirty teeth restored with metal-ceramic and all-ceramic crowns, properly adapted and with gaps of 0.30 and 0.50 mm, were submitted to micro-CT and CBCT scans. Linear measurements corresponding to the marginal gap (MG) and the absolute marginal discrepancy (AMD) were obtained. The objective assessment of the quality of CBCT images was performed using the contrast-to-noise ratio (CNR), and the subjective assessment was defined by the diagnoses made by five examiners regarding the presence or absence of gaps.

Results: The measurements were always higher for CBCT, with a significant difference regarding AMD. No significant difference in image quality was observed using CNR between the crowns tested. Low accuracy and sensitivity values could be observed for both crowns.

Conclusion: Marginal mismatch measures were overestimated in CBCT images. No difference in image quality was observed between the crowns. The correct diagnosis of gaps was considered low, irrespective of crown type and gap size.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
相关文献
二甲双胍通过HDAC6和FoxO3a转录调控肌肉生长抑制素诱导肌肉萎缩
IF 8.9 1区 医学Journal of Cachexia, Sarcopenia and MusclePub Date : 2021-11-02 DOI: 10.1002/jcsm.12833
Min Ju Kang, Ji Wook Moon, Jung Ok Lee, Ji Hae Kim, Eun Jeong Jung, Su Jin Kim, Joo Yeon Oh, Sang Woo Wu, Pu Reum Lee, Sun Hwa Park, Hyeon Soo Kim
具有疾病敏感单倍型的非亲属供体脐带血移植后的1型糖尿病
IF 3.2 3区 医学Journal of Diabetes InvestigationPub Date : 2022-11-02 DOI: 10.1111/jdi.13939
Kensuke Matsumoto, Taisuke Matsuyama, Ritsu Sumiyoshi, Matsuo Takuji, Tadashi Yamamoto, Ryosuke Shirasaki, Haruko Tashiro
封面:蛋白质组学分析确定IRSp53和fastin是PRV输出和直接细胞-细胞传播的关键
IF 3.4 4区 生物学ProteomicsPub Date : 2019-12-02 DOI: 10.1002/pmic.201970201
Fei-Long Yu, Huan Miao, Jinjin Xia, Fan Jia, Huadong Wang, Fuqiang Xu, Lin Guo
来源期刊
CiteScore
1.40
自引率
0.00%
发文量
23
审稿时长
25 weeks
期刊介绍: Journal of Dental Research Dental Clinics Dental Prospects (JODDD) is a Platinum* Open Access, peer-reviewed quarterly indexed journal that publishes articles of basic, clinical, and prospective nature in all areas of dentistry and oral health.
期刊最新文献
Effect of treatment variables on apical extrusion of debris during root canal retreatment: A systematic review and meta-analysis of laboratory studies. Effects of ethylenediaminetetraacetic acid, citric acid, and etidronic acid on root dentin mineral content and bond strength of a bioceramic-based sealer: A scanning electron microscopy-energy dispersive spectroscopy study. Evaluation of the accuracy of full-arch impressions between three different intraoral scanners and conventional impressions: A prospective in vivo study. Evaluation of the skeletal and dental effects of a hybrid aesthetic functional appliance (HAF) in skeletal class II division 1 malocclusion: A prospective uncontrolled clinical trial. Impact of dental caries on the daily lives of geriatric patients visiting dental hospitals in Rawalpindi, Pakistan.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1