{"title":"填充因子指数对研究股四头肌表面肌电信号填充过程的验证","authors":"Javier Rodriguez-Falces ,&nbsp;Armando Malanda ,&nbsp;Cristina Mariscal ,&nbsp;Imran Khan Niazi ,&nbsp;Javier Navallas","doi":"10.1016/j.jelekin.2023.102811","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>The EMG filling factor is an index to quantify the degree to which an EMG signal has been filled. Here, we tested the validity of such index to analyse the EMG filling process as contraction force was slowly increased.</p></div><div><h3>Methods</h3><p>Surface EMG signals were recorded from the <em>quadriceps</em> muscles of healthy subjects as force was gradually increased from 0 to 40% MVC. The sEMG filling process was analyzed by measuring the EMG filling factor (calculated from the non-central moments of the rectified sEMG).</p></div><div><h3>Results</h3><p>(1) As force was gradually increased, one or two prominent abrupt jumps in sEMG amplitude appeared between 0 and 10% of MVC force in all the <em>vastus lateralis</em> and <em>medialis</em>.</p><p>(2) The jumps in amplitude were originated when a few large-amplitude MUPs, clearly standing out from previous activity, appeared in the sEMG signal.</p><p>(3) Every time an abrupt jump in sEMG amplitude occurred, a new stage of sEMG filling was initiated.</p><p>(4) The sEMG was almost completely filled at 2–12% MVC.</p><p>(5) The filling factor decreased significantly upon the occurrence of an sEMG amplitude jump, and increased as additional MUPs were added to the sEMG signal.</p><p>(6) The filling factor curve was highly repeatable across repetitions.</p></div><div><h3>Conclusions</h3><p>It has been validated that the filling factor is a useful, reliable tool to analyse the sEMG filling process. As force was gradually increased in the vastus muscles, the sEMG filling process occurred in one or two stages due to the presence of abrupt jumps in sEMG amplitude.</p></div>","PeriodicalId":56123,"journal":{"name":"Journal of Electromyography and Kinesiology","volume":"72 ","pages":"Article 102811"},"PeriodicalIF":2.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of the filling factor index to study the filling process of the sEMG signal in the quadriceps\",\"authors\":\"Javier Rodriguez-Falces ,&nbsp;Armando Malanda ,&nbsp;Cristina Mariscal ,&nbsp;Imran Khan Niazi ,&nbsp;Javier Navallas\",\"doi\":\"10.1016/j.jelekin.2023.102811\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>The EMG filling factor is an index to quantify the degree to which an EMG signal has been filled. Here, we tested the validity of such index to analyse the EMG filling process as contraction force was slowly increased.</p></div><div><h3>Methods</h3><p>Surface EMG signals were recorded from the <em>quadriceps</em> muscles of healthy subjects as force was gradually increased from 0 to 40% MVC. The sEMG filling process was analyzed by measuring the EMG filling factor (calculated from the non-central moments of the rectified sEMG).</p></div><div><h3>Results</h3><p>(1) As force was gradually increased, one or two prominent abrupt jumps in sEMG amplitude appeared between 0 and 10% of MVC force in all the <em>vastus lateralis</em> and <em>medialis</em>.</p><p>(2) The jumps in amplitude were originated when a few large-amplitude MUPs, clearly standing out from previous activity, appeared in the sEMG signal.</p><p>(3) Every time an abrupt jump in sEMG amplitude occurred, a new stage of sEMG filling was initiated.</p><p>(4) The sEMG was almost completely filled at 2–12% MVC.</p><p>(5) The filling factor decreased significantly upon the occurrence of an sEMG amplitude jump, and increased as additional MUPs were added to the sEMG signal.</p><p>(6) The filling factor curve was highly repeatable across repetitions.</p></div><div><h3>Conclusions</h3><p>It has been validated that the filling factor is a useful, reliable tool to analyse the sEMG filling process. As force was gradually increased in the vastus muscles, the sEMG filling process occurred in one or two stages due to the presence of abrupt jumps in sEMG amplitude.</p></div>\",\"PeriodicalId\":56123,\"journal\":{\"name\":\"Journal of Electromyography and Kinesiology\",\"volume\":\"72 \",\"pages\":\"Article 102811\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electromyography and Kinesiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1050641123000706\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electromyography and Kinesiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1050641123000706","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

EMG填充因子是一个量化EMG信号填充程度的指标。在这里,我们测试了该指标的有效性,以分析收缩力缓慢增加时的肌电填充过程。方法记录健康受试者股四头肌表面肌电信号,受力范围从0%逐渐增加到40%。结果(1)随着用力的逐渐增加,股外侧肌和股内侧肌的肌电振幅出现一到两次明显的突变,突变幅度在MVC力的0到10%之间。(2) 振幅的跳跃是在sEMG信号中出现几个明显不同于先前活动的大振幅MUP时产生的。(3) 每当sEMG振幅突然跳跃时,sEMG填充的新阶段就开始了。(4) sEMG在2–12%的MVC时几乎完全充满。(5) 填充因子在sEMG振幅跳跃发生时显著降低,并且随着向sEMG信号添加额外的MUP而增加。(6) 填充因子曲线在重复中具有高度可重复性。结论充填因子是分析表面肌电充填过程的一种有用、可靠的工具。当股肌中的力逐渐增加时,由于表面肌电振幅的突然跳跃,表面肌电充盈过程发生在一个或两个阶段。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Validation of the filling factor index to study the filling process of the sEMG signal in the quadriceps

Introduction

The EMG filling factor is an index to quantify the degree to which an EMG signal has been filled. Here, we tested the validity of such index to analyse the EMG filling process as contraction force was slowly increased.

Methods

Surface EMG signals were recorded from the quadriceps muscles of healthy subjects as force was gradually increased from 0 to 40% MVC. The sEMG filling process was analyzed by measuring the EMG filling factor (calculated from the non-central moments of the rectified sEMG).

Results

(1) As force was gradually increased, one or two prominent abrupt jumps in sEMG amplitude appeared between 0 and 10% of MVC force in all the vastus lateralis and medialis.

(2) The jumps in amplitude were originated when a few large-amplitude MUPs, clearly standing out from previous activity, appeared in the sEMG signal.

(3) Every time an abrupt jump in sEMG amplitude occurred, a new stage of sEMG filling was initiated.

(4) The sEMG was almost completely filled at 2–12% MVC.

(5) The filling factor decreased significantly upon the occurrence of an sEMG amplitude jump, and increased as additional MUPs were added to the sEMG signal.

(6) The filling factor curve was highly repeatable across repetitions.

Conclusions

It has been validated that the filling factor is a useful, reliable tool to analyse the sEMG filling process. As force was gradually increased in the vastus muscles, the sEMG filling process occurred in one or two stages due to the presence of abrupt jumps in sEMG amplitude.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.70
自引率
8.00%
发文量
70
审稿时长
74 days
期刊介绍: Journal of Electromyography & Kinesiology is the primary source for outstanding original articles on the study of human movement from muscle contraction via its motor units and sensory system to integrated motion through mechanical and electrical detection techniques. As the official publication of the International Society of Electrophysiology and Kinesiology, the journal is dedicated to publishing the best work in all areas of electromyography and kinesiology, including: control of movement, muscle fatigue, muscle and nerve properties, joint biomechanics and electrical stimulation. Applications in rehabilitation, sports & exercise, motion analysis, ergonomics, alternative & complimentary medicine, measures of human performance and technical articles on electromyographic signal processing are welcome.
期刊最新文献
Inter-session Reliability of Magnetic Nerve Stimulation and Within-Session comparison to Electrical Nerve Stimulation in Evaluating Neuromuscular Function of Knee Extensor Muscles. Effect of tasks on intramuscular regional differences in rectus femoris elasticity during isometric contraction: An ultrasound shear wave elastography study. Flexor hallucis longus and tibialis anterior: A synergistic relationship. The unprecedented progresses in neuromechanics over the past 50 years - In celebration of the 50th anniversary of the international society of biomechanics. Wavelet-based time-frequency intermuscular beta-band coherence decreases with age but increases after mental fatigue in ankle muscles during gait independent of age.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1