Karla Regina Nogueira da Silva, Lucas Novaes Teixeira, Marcelo Lucchesi Teixeira, Guilherme Bovi Ambrosano, Elizabeth Ferreira Martinez
{"title":"短种植体:不同直径、扭矩和跨粘膜高度对循环后螺钉预载荷损失的影响","authors":"Karla Regina Nogueira da Silva, Lucas Novaes Teixeira, Marcelo Lucchesi Teixeira, Guilherme Bovi Ambrosano, Elizabeth Ferreira Martinez","doi":"10.1111/eos.12937","DOIUrl":null,"url":null,"abstract":"<p>This study evaluated the influence of different implant diameters, insertion torques, and transmucosal heights on the loosening of abutments installed on short implants, after mechanical cycling. The Morse taper connection implants (<i>n</i> = 96) tested were 5 mm high, divided according to the platform diameter: 4 or 6 mm. A universal abutment was coupled to each implant (with different transmucosal heights: 1 or 5 mm). The sets were subdivided into 20- and 32-Ncm torque. After the cycle fatigue test, the detorque values were measured with a digital torque indicator. After mechanical cycling, the mean detorque values obtained for the abutment with 20-Ncm insertion torque were lower than for implants with 32-Ncm insertion torque, regardless of the platform diameter or transmucosal height. In the 20-Ncm torque group, there was no statistically significant difference in the detorque values between platform diameters or transmucosal heights. Otherwise, for 32-Ncm sets, a smaller platform diameter (4 mm), and a longer transmucosal height (5 mm) showed the lowest detorque values. In conclusion, implants placed with 32-Ncm insertion torque and abutments with 1 mm transmucosal height and a 6 mm implant diameter demonstrated the highest detorque values.</p>","PeriodicalId":11983,"journal":{"name":"European Journal of Oral Sciences","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2023-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Short implants: Influence of different diameters, torques, and transmucosal heights of straight prosthetic abutments on screw preload loss after cycling\",\"authors\":\"Karla Regina Nogueira da Silva, Lucas Novaes Teixeira, Marcelo Lucchesi Teixeira, Guilherme Bovi Ambrosano, Elizabeth Ferreira Martinez\",\"doi\":\"10.1111/eos.12937\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>This study evaluated the influence of different implant diameters, insertion torques, and transmucosal heights on the loosening of abutments installed on short implants, after mechanical cycling. The Morse taper connection implants (<i>n</i> = 96) tested were 5 mm high, divided according to the platform diameter: 4 or 6 mm. A universal abutment was coupled to each implant (with different transmucosal heights: 1 or 5 mm). The sets were subdivided into 20- and 32-Ncm torque. After the cycle fatigue test, the detorque values were measured with a digital torque indicator. After mechanical cycling, the mean detorque values obtained for the abutment with 20-Ncm insertion torque were lower than for implants with 32-Ncm insertion torque, regardless of the platform diameter or transmucosal height. In the 20-Ncm torque group, there was no statistically significant difference in the detorque values between platform diameters or transmucosal heights. Otherwise, for 32-Ncm sets, a smaller platform diameter (4 mm), and a longer transmucosal height (5 mm) showed the lowest detorque values. In conclusion, implants placed with 32-Ncm insertion torque and abutments with 1 mm transmucosal height and a 6 mm implant diameter demonstrated the highest detorque values.</p>\",\"PeriodicalId\":11983,\"journal\":{\"name\":\"European Journal of Oral Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Oral Sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/eos.12937\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Oral Sciences","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/eos.12937","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Short implants: Influence of different diameters, torques, and transmucosal heights of straight prosthetic abutments on screw preload loss after cycling
This study evaluated the influence of different implant diameters, insertion torques, and transmucosal heights on the loosening of abutments installed on short implants, after mechanical cycling. The Morse taper connection implants (n = 96) tested were 5 mm high, divided according to the platform diameter: 4 or 6 mm. A universal abutment was coupled to each implant (with different transmucosal heights: 1 or 5 mm). The sets were subdivided into 20- and 32-Ncm torque. After the cycle fatigue test, the detorque values were measured with a digital torque indicator. After mechanical cycling, the mean detorque values obtained for the abutment with 20-Ncm insertion torque were lower than for implants with 32-Ncm insertion torque, regardless of the platform diameter or transmucosal height. In the 20-Ncm torque group, there was no statistically significant difference in the detorque values between platform diameters or transmucosal heights. Otherwise, for 32-Ncm sets, a smaller platform diameter (4 mm), and a longer transmucosal height (5 mm) showed the lowest detorque values. In conclusion, implants placed with 32-Ncm insertion torque and abutments with 1 mm transmucosal height and a 6 mm implant diameter demonstrated the highest detorque values.
期刊介绍:
The European Journal of Oral Sciences is an international journal which publishes original research papers within clinical dentistry, on all basic science aspects of structure, chemistry, developmental biology, physiology and pathology of relevant tissues, as well as on microbiology, biomaterials and the behavioural sciences as they relate to dentistry. In general, analytical studies are preferred to descriptive ones. Reviews, Short Communications and Letters to the Editor will also be considered for publication.
The journal is published bimonthly.