短种植体:不同直径、扭矩和跨粘膜高度对循环后螺钉预载荷损失的影响

IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE European Journal of Oral Sciences Pub Date : 2023-05-22 DOI:10.1111/eos.12937
Karla Regina Nogueira da Silva, Lucas Novaes Teixeira, Marcelo Lucchesi Teixeira, Guilherme Bovi Ambrosano, Elizabeth Ferreira Martinez
{"title":"短种植体:不同直径、扭矩和跨粘膜高度对循环后螺钉预载荷损失的影响","authors":"Karla Regina Nogueira da Silva,&nbsp;Lucas Novaes Teixeira,&nbsp;Marcelo Lucchesi Teixeira,&nbsp;Guilherme Bovi Ambrosano,&nbsp;Elizabeth Ferreira Martinez","doi":"10.1111/eos.12937","DOIUrl":null,"url":null,"abstract":"<p>This study evaluated the influence of different implant diameters, insertion torques, and transmucosal heights on the loosening of abutments installed on short implants, after mechanical cycling. The Morse taper connection implants (<i>n</i> = 96) tested were 5 mm high, divided according to the platform diameter: 4 or 6 mm. A universal abutment was coupled to each implant (with different transmucosal heights: 1 or 5 mm). The sets were subdivided into 20- and 32-Ncm torque. After the cycle fatigue test, the detorque values were measured with a digital torque indicator. After mechanical cycling, the mean detorque values obtained for the abutment with 20-Ncm insertion torque were lower than for implants with 32-Ncm insertion torque, regardless of the platform diameter or transmucosal height. In the 20-Ncm torque group, there was no statistically significant difference in the detorque values between platform diameters or transmucosal heights. Otherwise, for 32-Ncm sets, a smaller platform diameter (4 mm), and a longer transmucosal height (5 mm) showed the lowest detorque values. In conclusion, implants placed with 32-Ncm insertion torque and abutments with 1 mm transmucosal height and a 6 mm implant diameter demonstrated the highest detorque values.</p>","PeriodicalId":11983,"journal":{"name":"European Journal of Oral Sciences","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2023-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Short implants: Influence of different diameters, torques, and transmucosal heights of straight prosthetic abutments on screw preload loss after cycling\",\"authors\":\"Karla Regina Nogueira da Silva,&nbsp;Lucas Novaes Teixeira,&nbsp;Marcelo Lucchesi Teixeira,&nbsp;Guilherme Bovi Ambrosano,&nbsp;Elizabeth Ferreira Martinez\",\"doi\":\"10.1111/eos.12937\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>This study evaluated the influence of different implant diameters, insertion torques, and transmucosal heights on the loosening of abutments installed on short implants, after mechanical cycling. The Morse taper connection implants (<i>n</i> = 96) tested were 5 mm high, divided according to the platform diameter: 4 or 6 mm. A universal abutment was coupled to each implant (with different transmucosal heights: 1 or 5 mm). The sets were subdivided into 20- and 32-Ncm torque. After the cycle fatigue test, the detorque values were measured with a digital torque indicator. After mechanical cycling, the mean detorque values obtained for the abutment with 20-Ncm insertion torque were lower than for implants with 32-Ncm insertion torque, regardless of the platform diameter or transmucosal height. In the 20-Ncm torque group, there was no statistically significant difference in the detorque values between platform diameters or transmucosal heights. Otherwise, for 32-Ncm sets, a smaller platform diameter (4 mm), and a longer transmucosal height (5 mm) showed the lowest detorque values. In conclusion, implants placed with 32-Ncm insertion torque and abutments with 1 mm transmucosal height and a 6 mm implant diameter demonstrated the highest detorque values.</p>\",\"PeriodicalId\":11983,\"journal\":{\"name\":\"European Journal of Oral Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Oral Sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/eos.12937\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Oral Sciences","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/eos.12937","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

本研究评估了机械循环后不同种植体直径、插入扭矩和跨粘膜高度对短种植体基台松动的影响。测试的Morse锥度连接植入物(n = 96)高度为5mm,根据平台直径分为4或6 mm。通用基台连接到每个种植体(不同的粘膜高度:1或5毫米)。这些装置被细分为20和32 ncm扭矩。循环疲劳试验结束后,用数字转矩指示器测量转矩值。机械循环后,无论平台直径或经黏膜高度如何,插入扭矩为20 ncm的基台获得的平均解扭矩值低于插入扭矩为32 ncm的种植体。在扭矩为20 ncm的组中,平台直径和粘膜高度之间的脱扭矩值无统计学差异。另外,对于32-Ncm组,较小的平台直径(4 mm)和较长的粘膜高度(5 mm)显示最低的脱扭矩值。综上所述,植体置入扭矩为32-Ncm、基台经黏膜高度为1mm、种植体直径为6mm的植体,其去扭矩值最高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Short implants: Influence of different diameters, torques, and transmucosal heights of straight prosthetic abutments on screw preload loss after cycling

This study evaluated the influence of different implant diameters, insertion torques, and transmucosal heights on the loosening of abutments installed on short implants, after mechanical cycling. The Morse taper connection implants (n = 96) tested were 5 mm high, divided according to the platform diameter: 4 or 6 mm. A universal abutment was coupled to each implant (with different transmucosal heights: 1 or 5 mm). The sets were subdivided into 20- and 32-Ncm torque. After the cycle fatigue test, the detorque values were measured with a digital torque indicator. After mechanical cycling, the mean detorque values obtained for the abutment with 20-Ncm insertion torque were lower than for implants with 32-Ncm insertion torque, regardless of the platform diameter or transmucosal height. In the 20-Ncm torque group, there was no statistically significant difference in the detorque values between platform diameters or transmucosal heights. Otherwise, for 32-Ncm sets, a smaller platform diameter (4 mm), and a longer transmucosal height (5 mm) showed the lowest detorque values. In conclusion, implants placed with 32-Ncm insertion torque and abutments with 1 mm transmucosal height and a 6 mm implant diameter demonstrated the highest detorque values.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Journal of Oral Sciences
European Journal of Oral Sciences 医学-牙科与口腔外科
CiteScore
3.50
自引率
5.30%
发文量
61
审稿时长
2 months
期刊介绍: The European Journal of Oral Sciences is an international journal which publishes original research papers within clinical dentistry, on all basic science aspects of structure, chemistry, developmental biology, physiology and pathology of relevant tissues, as well as on microbiology, biomaterials and the behavioural sciences as they relate to dentistry. In general, analytical studies are preferred to descriptive ones. Reviews, Short Communications and Letters to the Editor will also be considered for publication. The journal is published bimonthly.
期刊最新文献
Bond strength of resin-based restorative materials to fast-setting calcium silicate cement using different resin adhesive systems. Different adhesive approaches for the bonding of a new universal resin cement to a disilicate glass-ceramic. Psychological resilience in patients with primary Sjögren's syndrome: effect of involvement of major salivary and lacrimal glands. Effect of propolis added to single-bottle adhesives on water permeation through the hybrid layer. Three-dimensional finite element analysis of the impact of access cavity preparation on first molar fracture resistance: A scoping review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1