在湿热条件下进行间歇性体育活动时,单独使用电扇或与冰浆/冷水摄入和小腿浸泡相结合使用电扇对年轻男性的影响。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2023-11-01 Epub Date: 2023-09-12 DOI:10.1139/apnm-2023-0013
Thomas A Deshayes, Timothée Pancrate, Eric D B Goulet
{"title":"在湿热条件下进行间歇性体育活动时,单独使用电扇或与冰浆/冷水摄入和小腿浸泡相结合使用电扇对年轻男性的影响。","authors":"Thomas A Deshayes,&nbsp;Timothée Pancrate,&nbsp;Eric D B Goulet","doi":"10.1139/apnm-2023-0013","DOIUrl":null,"url":null,"abstract":"<p><p>Using a randomized crossover protocol, 10 young men completed four 180 min exposures (38 °C, 60% relative humidity), alternating between 30 min of walking and 30 min of sitting where fluid or ice slurry were served. Participants underwent four trials: (i) 5 mL·kg body mass<sup>-1</sup> of 20 °C water (CON); (ii) 5 mL·kg body mass<sup>-1</sup> of 20 °C water + fan at 4 m·s<sup>-1</sup> (FAN); (iii) fan + 3 mL·kg body mass<sup>-1</sup> of ice slurry + 2 mL·kg body mass<sup>-1</sup> of 4 °C water (FAN + ISCW); and (iv) FAN + ISCW + lower-leg immersion in 20 °C water (FAN + ISCW + LLI). Sweat and body mass losses were higher with FAN than CON, FAN + ISCW, and FAN + ISCW + LLI. Mean and peak changes in Δrectal temperature, heart rate, and perceived heat and thirst from baseline were not statistically and practically different between FAN and CON. FAN + ISCW + LLI decreased sweat loss compared with FAN + ISCW and mean and peak changes in Δrectal temperature, heart rate, and perceived thirst compared with CON. FAN + ISCW + LLI also attenuated the changes in Δrectal temperature (peak) and thirst (mean and peak) compared with FAN. In conclusion, FAN slightly exacerbates fluid loss but does not attenuate the changes in Δrectal temperature, heart rate, and perceived heat and thirst during intermittent physical activity in hot-humid conditions. However, coupling ISCW or ISCW + LLI with the use of a fan attenuates the increase in these outcomes compared with no intervention and to a greater extent for rectal temperature and thirst when fan is coupled with ISCW + LLI than when it is used in isolation.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of electric fan use in isolation or combined with ice slurry/cold water ingestion and lower-leg immersion in young men during intermittent physical activity in hot-humid conditions.\",\"authors\":\"Thomas A Deshayes,&nbsp;Timothée Pancrate,&nbsp;Eric D B Goulet\",\"doi\":\"10.1139/apnm-2023-0013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Using a randomized crossover protocol, 10 young men completed four 180 min exposures (38 °C, 60% relative humidity), alternating between 30 min of walking and 30 min of sitting where fluid or ice slurry were served. Participants underwent four trials: (i) 5 mL·kg body mass<sup>-1</sup> of 20 °C water (CON); (ii) 5 mL·kg body mass<sup>-1</sup> of 20 °C water + fan at 4 m·s<sup>-1</sup> (FAN); (iii) fan + 3 mL·kg body mass<sup>-1</sup> of ice slurry + 2 mL·kg body mass<sup>-1</sup> of 4 °C water (FAN + ISCW); and (iv) FAN + ISCW + lower-leg immersion in 20 °C water (FAN + ISCW + LLI). Sweat and body mass losses were higher with FAN than CON, FAN + ISCW, and FAN + ISCW + LLI. Mean and peak changes in Δrectal temperature, heart rate, and perceived heat and thirst from baseline were not statistically and practically different between FAN and CON. FAN + ISCW + LLI decreased sweat loss compared with FAN + ISCW and mean and peak changes in Δrectal temperature, heart rate, and perceived thirst compared with CON. FAN + ISCW + LLI also attenuated the changes in Δrectal temperature (peak) and thirst (mean and peak) compared with FAN. In conclusion, FAN slightly exacerbates fluid loss but does not attenuate the changes in Δrectal temperature, heart rate, and perceived heat and thirst during intermittent physical activity in hot-humid conditions. However, coupling ISCW or ISCW + LLI with the use of a fan attenuates the increase in these outcomes compared with no intervention and to a greater extent for rectal temperature and thirst when fan is coupled with ISCW + LLI than when it is used in isolation.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1139/apnm-2023-0013\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1139/apnm-2023-0013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/12 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

使用随机交叉方案,10名年轻男子完成了四次180分钟的暴露(38°C,60%相对湿度),在提供液体或冰浆的地方,交替步行30分钟和坐着30分钟。参与者接受了四项试验:(i)5 mL·kg体重-1的20°C水(CON);(ii)5 mL·kg体重-1的20°C水+4 m·s-1的风扇(fan);(iii)风扇+3 mL·kg体重-1的冰浆+2 mL·kg质量-1的4°C水(fan+ISCW);以及(iv)FAN+ISCW+小腿浸入20°C水中(FAN+ISCW+LLI)。FAN组的汗液和体重损失高于CON、FAN+ISCW和FAN+ISCW+LLI组。从基线开始,Δ直肠温度、心率、感知热和口渴的平均和峰值变化在FAN和CON之间没有统计学和实践上的差异。与FAN+ISCW相比,FAN+ISCW+LLI减少了汗液流失,与CON相比,Δ直肠温度、心率和感知口渴的平均变化和峰值变化减少。与FAN相比,FAN+ISCW+LLI还减弱了Δ直肠温度(峰值)和口渴(平均值和峰值)的变化。总之,在湿热条件下进行间歇性体育活动时,FAN会略微加重液体损失,但不会减弱Δ直肠温度、心率以及感知到的热和口渴的变化。然而,与不干预相比,将ISCW或ISCW+LLI与风扇结合使用可以减弱这些结果的增加,并且当风扇与ISCW+LLI结合使用时,与单独使用时相比,可以在更大程度上减轻直肠温度和口渴。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of electric fan use in isolation or combined with ice slurry/cold water ingestion and lower-leg immersion in young men during intermittent physical activity in hot-humid conditions.

Using a randomized crossover protocol, 10 young men completed four 180 min exposures (38 °C, 60% relative humidity), alternating between 30 min of walking and 30 min of sitting where fluid or ice slurry were served. Participants underwent four trials: (i) 5 mL·kg body mass-1 of 20 °C water (CON); (ii) 5 mL·kg body mass-1 of 20 °C water + fan at 4 m·s-1 (FAN); (iii) fan + 3 mL·kg body mass-1 of ice slurry + 2 mL·kg body mass-1 of 4 °C water (FAN + ISCW); and (iv) FAN + ISCW + lower-leg immersion in 20 °C water (FAN + ISCW + LLI). Sweat and body mass losses were higher with FAN than CON, FAN + ISCW, and FAN + ISCW + LLI. Mean and peak changes in Δrectal temperature, heart rate, and perceived heat and thirst from baseline were not statistically and practically different between FAN and CON. FAN + ISCW + LLI decreased sweat loss compared with FAN + ISCW and mean and peak changes in Δrectal temperature, heart rate, and perceived thirst compared with CON. FAN + ISCW + LLI also attenuated the changes in Δrectal temperature (peak) and thirst (mean and peak) compared with FAN. In conclusion, FAN slightly exacerbates fluid loss but does not attenuate the changes in Δrectal temperature, heart rate, and perceived heat and thirst during intermittent physical activity in hot-humid conditions. However, coupling ISCW or ISCW + LLI with the use of a fan attenuates the increase in these outcomes compared with no intervention and to a greater extent for rectal temperature and thirst when fan is coupled with ISCW + LLI than when it is used in isolation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1