标准化HER2免疫组织化学评估:校正染色和扫描引起的全片成像的颜色和强度变化

Q3 Immunology and Microbiology Applied Microscopy Pub Date : 2023-09-14 DOI:10.1186/s42649-023-00091-8
Chie Ohnishi, Takashi Ohnishi, Peter Ntiamoah, Dara S. Ross, Masahiro Yamaguchi, Yukako Yagi
{"title":"标准化HER2免疫组织化学评估:校正染色和扫描引起的全片成像的颜色和强度变化","authors":"Chie Ohnishi,&nbsp;Takashi Ohnishi,&nbsp;Peter Ntiamoah,&nbsp;Dara S. Ross,&nbsp;Masahiro Yamaguchi,&nbsp;Yukako Yagi","doi":"10.1186/s42649-023-00091-8","DOIUrl":null,"url":null,"abstract":"<div><p>In the evaluation of human epidermal growth factor receptor 2 (HER2) immunohistochemistry (IHC) — one of the standard biomarkers for breast cancer— visual assessment is laborious and subjective. Image analysis using whole slide image (WSI) could produce more consistent results; however, color variability in WSIs due to the choice of stain and scanning processes may impact image analysis. We therefore developed a calibration protocol to diminish the staining and scanning variations of WSI using two calibrator slides. The IHC calibrator slide (IHC-CS) contains peptide-coated microbeads with different concentrations. The color distribution obtained from the WSI of stained IHC-CS reflects the staining process and scanner characteristics. A color chart slide (CCS) is also useful for calibrating the color variation due to the scanner. The results of the automated HER2 assessment were compared to confirm the effectiveness of two calibration slides. The IHC-CS and HER2 breast cancer cases were stained on different days. All stained slides and CCS were digitized by two different WSI scanners. Results revealed 100% concordance between automated evaluation and the pathologist’s assessment with both the scanner and staining calibration. The proposed method may enable consistent evaluation of HER2.</p></div>","PeriodicalId":470,"journal":{"name":"Applied Microscopy","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10499734/pdf/","citationCount":"0","resultStr":"{\"title\":\"Standardizing HER2 immunohistochemistry assessment: calibration of color and intensity variation in whole slide imaging caused by staining and scanning\",\"authors\":\"Chie Ohnishi,&nbsp;Takashi Ohnishi,&nbsp;Peter Ntiamoah,&nbsp;Dara S. Ross,&nbsp;Masahiro Yamaguchi,&nbsp;Yukako Yagi\",\"doi\":\"10.1186/s42649-023-00091-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In the evaluation of human epidermal growth factor receptor 2 (HER2) immunohistochemistry (IHC) — one of the standard biomarkers for breast cancer— visual assessment is laborious and subjective. Image analysis using whole slide image (WSI) could produce more consistent results; however, color variability in WSIs due to the choice of stain and scanning processes may impact image analysis. We therefore developed a calibration protocol to diminish the staining and scanning variations of WSI using two calibrator slides. The IHC calibrator slide (IHC-CS) contains peptide-coated microbeads with different concentrations. The color distribution obtained from the WSI of stained IHC-CS reflects the staining process and scanner characteristics. A color chart slide (CCS) is also useful for calibrating the color variation due to the scanner. The results of the automated HER2 assessment were compared to confirm the effectiveness of two calibration slides. The IHC-CS and HER2 breast cancer cases were stained on different days. All stained slides and CCS were digitized by two different WSI scanners. Results revealed 100% concordance between automated evaluation and the pathologist’s assessment with both the scanner and staining calibration. The proposed method may enable consistent evaluation of HER2.</p></div>\",\"PeriodicalId\":470,\"journal\":{\"name\":\"Applied Microscopy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10499734/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Microscopy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.1186/s42649-023-00091-8\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Immunology and Microbiology\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Microscopy","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s42649-023-00091-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Immunology and Microbiology","Score":null,"Total":0}
引用次数: 0

摘要

人表皮生长因子受体2 (HER2)免疫组织化学(IHC)是乳腺癌的标准生物标志物之一,在评估中,视觉评估是费力和主观的。使用全幻灯片图像(WSI)进行图像分析可以得到更一致的结果;然而,由于染色和扫描过程的选择,wsi的颜色变化可能会影响图像分析。因此,我们开发了一种校准方案,以减少使用两个校准载玻片的WSI染色和扫描变化。IHC校定剂载玻片(IHC- cs)含有不同浓度的肽包被微珠。IHC-CS染色WSI得到的颜色分布反映了染色过程和扫描仪特征。彩色图表幻灯片(CCS)对于校准由于扫描仪引起的颜色变化也很有用。将自动HER2评估结果进行比较,以确认两种校准载玻片的有效性。IHC-CS和HER2乳腺癌患者在不同时间进行染色。所有染色的载玻片和CCS通过两台不同的WSI扫描仪进行数字化处理。结果显示,自动评估和病理学家的评估与扫描仪和染色校准100%一致。所提出的方法可以实现HER2的一致性评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Standardizing HER2 immunohistochemistry assessment: calibration of color and intensity variation in whole slide imaging caused by staining and scanning

In the evaluation of human epidermal growth factor receptor 2 (HER2) immunohistochemistry (IHC) — one of the standard biomarkers for breast cancer— visual assessment is laborious and subjective. Image analysis using whole slide image (WSI) could produce more consistent results; however, color variability in WSIs due to the choice of stain and scanning processes may impact image analysis. We therefore developed a calibration protocol to diminish the staining and scanning variations of WSI using two calibrator slides. The IHC calibrator slide (IHC-CS) contains peptide-coated microbeads with different concentrations. The color distribution obtained from the WSI of stained IHC-CS reflects the staining process and scanner characteristics. A color chart slide (CCS) is also useful for calibrating the color variation due to the scanner. The results of the automated HER2 assessment were compared to confirm the effectiveness of two calibration slides. The IHC-CS and HER2 breast cancer cases were stained on different days. All stained slides and CCS were digitized by two different WSI scanners. Results revealed 100% concordance between automated evaluation and the pathologist’s assessment with both the scanner and staining calibration. The proposed method may enable consistent evaluation of HER2.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Microscopy
Applied Microscopy Immunology and Microbiology-Applied Microbiology and Biotechnology
CiteScore
3.40
自引率
0.00%
发文量
10
审稿时长
10 weeks
期刊介绍: Applied Microscopy is a peer-reviewed journal sponsored by the Korean Society of Microscopy. The journal covers all the interdisciplinary fields of technological developments in new microscopy methods and instrumentation and their applications to biological or materials science for determining structure and chemistry. ISSN: 22875123, 22874445.
期刊最新文献
Clearing techniques for deeper imaging of plants and plant–microbe interactions Noise reduction of electron holography observations for a thin-foiled Nd-Fe-B specimen using the wavelet hidden Markov model Microstructure of the silk fibroin-based hydrogel scaffolds derived from the orb-web spider Trichonephila clavata Changes of synaptic vesicles in three-dimensional synapse models by treatment with umbelliferone in scopolamine-induced hippocampal injury model A simple and rapid preparation of smooth muscle myosin 2 for the electron microscopic analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1