Lei Tian, Tong Zhao, Lei Dong, Qiwen Liu, Yu Zheng
{"title":"基于多载波无线柔性控制的被动阵列微磁刺激装置,用于磁神经调控。","authors":"Lei Tian, Tong Zhao, Lei Dong, Qiwen Liu, Yu Zheng","doi":"10.1088/1741-2552/acfa23","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>The passive micro-magnetic stimulation (<i>µ</i>MS) devices typically consist of an external transmitting coil and a single internal micro-coil, which enables a point-to-point energy supply from the external coil to the internal coil and the realization of magnetic neuromodulation via wireless energy transmission. The internal array of micro coils can achieve multi-target stimulation without movement, which improves the focus and effectiveness of magnetic stimulations. However, achieving a free selection of an appropriate external coil to deliver energy to a particular internal array of micro-coils for multiple stimulation targets has been challenging. To address this challenge, this study uses a multi-carrier modulation technique to transmit the energy of the external coil.<i>Approach.</i>In this study, a theoretical model of a multi-carrier resonant compensation network for the array<i>µ</i>MS is established based on the principle of magnetically coupled resonance. The resonant frequency coupling parameter corresponding to each micro-coil of the array<i>µ</i>MS is determined, and the magnetic field interference between the external coil and its non-resonant micro-coils is eliminated. Therefore, an effective magnetic stimulation threshold for a micro-coil corresponding to the target is determined, and wireless free control of the internal micro-coil array is achieved by using an external transmitting coil.<i>Main results.</i>The passive<i>µ</i>MS array model is designed using a multi-carrier wireless modulation method, and its synergistic modulation of the magnetic stimulation of synaptic plasticity long-term potentiation in multiple hippocampal regions is investigated using hippocampal isolated brain slices.<i>Significance.</i>The results presented in this study could provide theoretical and experimental bases for implantable micro-magnetic device-targeted therapy, introducing an efficient method for diagnosis and treatment of neurological diseases and providing innovative ideas for in-depth application of micro-magnetic stimulation in the neuroscience field.</p>","PeriodicalId":16753,"journal":{"name":"Journal of neural engineering","volume":" ","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2023-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Passive array micro-magnetic stimulation device based on multi-carrier wireless flexible control for magnetic neuromodulation.\",\"authors\":\"Lei Tian, Tong Zhao, Lei Dong, Qiwen Liu, Yu Zheng\",\"doi\":\"10.1088/1741-2552/acfa23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><i>Objective.</i>The passive micro-magnetic stimulation (<i>µ</i>MS) devices typically consist of an external transmitting coil and a single internal micro-coil, which enables a point-to-point energy supply from the external coil to the internal coil and the realization of magnetic neuromodulation via wireless energy transmission. The internal array of micro coils can achieve multi-target stimulation without movement, which improves the focus and effectiveness of magnetic stimulations. However, achieving a free selection of an appropriate external coil to deliver energy to a particular internal array of micro-coils for multiple stimulation targets has been challenging. To address this challenge, this study uses a multi-carrier modulation technique to transmit the energy of the external coil.<i>Approach.</i>In this study, a theoretical model of a multi-carrier resonant compensation network for the array<i>µ</i>MS is established based on the principle of magnetically coupled resonance. The resonant frequency coupling parameter corresponding to each micro-coil of the array<i>µ</i>MS is determined, and the magnetic field interference between the external coil and its non-resonant micro-coils is eliminated. Therefore, an effective magnetic stimulation threshold for a micro-coil corresponding to the target is determined, and wireless free control of the internal micro-coil array is achieved by using an external transmitting coil.<i>Main results.</i>The passive<i>µ</i>MS array model is designed using a multi-carrier wireless modulation method, and its synergistic modulation of the magnetic stimulation of synaptic plasticity long-term potentiation in multiple hippocampal regions is investigated using hippocampal isolated brain slices.<i>Significance.</i>The results presented in this study could provide theoretical and experimental bases for implantable micro-magnetic device-targeted therapy, introducing an efficient method for diagnosis and treatment of neurological diseases and providing innovative ideas for in-depth application of micro-magnetic stimulation in the neuroscience field.</p>\",\"PeriodicalId\":16753,\"journal\":{\"name\":\"Journal of neural engineering\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2023-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of neural engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1088/1741-2552/acfa23\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neural engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1741-2552/acfa23","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Passive array micro-magnetic stimulation device based on multi-carrier wireless flexible control for magnetic neuromodulation.
Objective.The passive micro-magnetic stimulation (µMS) devices typically consist of an external transmitting coil and a single internal micro-coil, which enables a point-to-point energy supply from the external coil to the internal coil and the realization of magnetic neuromodulation via wireless energy transmission. The internal array of micro coils can achieve multi-target stimulation without movement, which improves the focus and effectiveness of magnetic stimulations. However, achieving a free selection of an appropriate external coil to deliver energy to a particular internal array of micro-coils for multiple stimulation targets has been challenging. To address this challenge, this study uses a multi-carrier modulation technique to transmit the energy of the external coil.Approach.In this study, a theoretical model of a multi-carrier resonant compensation network for the arrayµMS is established based on the principle of magnetically coupled resonance. The resonant frequency coupling parameter corresponding to each micro-coil of the arrayµMS is determined, and the magnetic field interference between the external coil and its non-resonant micro-coils is eliminated. Therefore, an effective magnetic stimulation threshold for a micro-coil corresponding to the target is determined, and wireless free control of the internal micro-coil array is achieved by using an external transmitting coil.Main results.The passiveµMS array model is designed using a multi-carrier wireless modulation method, and its synergistic modulation of the magnetic stimulation of synaptic plasticity long-term potentiation in multiple hippocampal regions is investigated using hippocampal isolated brain slices.Significance.The results presented in this study could provide theoretical and experimental bases for implantable micro-magnetic device-targeted therapy, introducing an efficient method for diagnosis and treatment of neurological diseases and providing innovative ideas for in-depth application of micro-magnetic stimulation in the neuroscience field.
期刊介绍:
The goal of Journal of Neural Engineering (JNE) is to act as a forum for the interdisciplinary field of neural engineering where neuroscientists, neurobiologists and engineers can publish their work in one periodical that bridges the gap between neuroscience and engineering. The journal publishes articles in the field of neural engineering at the molecular, cellular and systems levels.
The scope of the journal encompasses experimental, computational, theoretical, clinical and applied aspects of: Innovative neurotechnology; Brain-machine (computer) interface; Neural interfacing; Bioelectronic medicines; Neuromodulation; Neural prostheses; Neural control; Neuro-rehabilitation; Neurorobotics; Optical neural engineering; Neural circuits: artificial & biological; Neuromorphic engineering; Neural tissue regeneration; Neural signal processing; Theoretical and computational neuroscience; Systems neuroscience; Translational neuroscience; Neuroimaging.