冷冻治疗对Neoniti旋转器械抗骨折性能的影响。

Q3 Dentistry Frontiers in Dentistry Pub Date : 2023-08-05 eCollection Date: 2023-01-01 DOI:10.18502/fid.v20i28.13346
Firouz Zadfatah, Saeedeh Galledar, Shahram Pourasgar, Alireza Fathiazar
{"title":"冷冻治疗对Neoniti旋转器械抗骨折性能的影响。","authors":"Firouz Zadfatah,&nbsp;Saeedeh Galledar,&nbsp;Shahram Pourasgar,&nbsp;Alireza Fathiazar","doi":"10.18502/fid.v20i28.13346","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objectives:</b> Nickel-titanium (NiTi) rotary files were introduced to optimize root canal instrumentation in endodontic treatment. However, despite the numerous advantages of NiTi instruments, they may unexpectedly break during clinical use, resulting in obstruction of the root canal system. This investigation aimed to assess the effect of cryotherapy on fracture resistance of Neoniti rotary files. <b>Materials and Methods:</b> This in vitro, study was conducted on 20 Neoniti rotary files with #35 tip size and 6% taper in two groups with and without cryogenic treatment (N=10). For cryogenic treatment, the files were immersed in liquid nitrogen at -196°C for 24 hours. Next, the Neoniti files in both groups were subjected to cyclic fatigue testing in a hand-piece operating at 500 rpm with 20 N/cm torque. The files were rotated until fracture and the fracture time as well as the number of cycles to fracture were recorded for each file. The two groups were compared by independent t-test at 0.05 level of significance. <b>Results:</b> The number of cycles to fracture was 235700±50649.22 in the control and 280600±22979.21 in the cryotherapy group. The mean fracture time was 471.40±101.29 and 561.20±45.958 seconds in the control and cryotherapy groups, respectively. Significant differences in both variables were noted between the two groups (P<0.05). <b>Conclusion:</b> Based on our findings, utilizing cryogenic treatment may enhance the fracture resistance of rotary instruments, making it a beneficial practice for dental clinicians to adopt. By using cryogenically treated rotary instruments, clinicians can potentially reduce the risk of file fracture during dental procedures.</p>","PeriodicalId":12445,"journal":{"name":"Frontiers in Dentistry","volume":"20 ","pages":"28"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/5e/39/FID-20-28.PMC10505447.pdf","citationCount":"0","resultStr":"{\"title\":\"Effect of Cryotherapy on Fracture Resistance of Neoniti Rotary Instruments.\",\"authors\":\"Firouz Zadfatah,&nbsp;Saeedeh Galledar,&nbsp;Shahram Pourasgar,&nbsp;Alireza Fathiazar\",\"doi\":\"10.18502/fid.v20i28.13346\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objectives:</b> Nickel-titanium (NiTi) rotary files were introduced to optimize root canal instrumentation in endodontic treatment. However, despite the numerous advantages of NiTi instruments, they may unexpectedly break during clinical use, resulting in obstruction of the root canal system. This investigation aimed to assess the effect of cryotherapy on fracture resistance of Neoniti rotary files. <b>Materials and Methods:</b> This in vitro, study was conducted on 20 Neoniti rotary files with #35 tip size and 6% taper in two groups with and without cryogenic treatment (N=10). For cryogenic treatment, the files were immersed in liquid nitrogen at -196°C for 24 hours. Next, the Neoniti files in both groups were subjected to cyclic fatigue testing in a hand-piece operating at 500 rpm with 20 N/cm torque. The files were rotated until fracture and the fracture time as well as the number of cycles to fracture were recorded for each file. The two groups were compared by independent t-test at 0.05 level of significance. <b>Results:</b> The number of cycles to fracture was 235700±50649.22 in the control and 280600±22979.21 in the cryotherapy group. The mean fracture time was 471.40±101.29 and 561.20±45.958 seconds in the control and cryotherapy groups, respectively. Significant differences in both variables were noted between the two groups (P<0.05). <b>Conclusion:</b> Based on our findings, utilizing cryogenic treatment may enhance the fracture resistance of rotary instruments, making it a beneficial practice for dental clinicians to adopt. By using cryogenically treated rotary instruments, clinicians can potentially reduce the risk of file fracture during dental procedures.</p>\",\"PeriodicalId\":12445,\"journal\":{\"name\":\"Frontiers in Dentistry\",\"volume\":\"20 \",\"pages\":\"28\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/5e/39/FID-20-28.PMC10505447.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers in Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18502/fid.v20i28.13346\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/fid.v20i28.13346","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:采用镍钛(NiTi)旋转锉优化根管器械在根管治疗中的应用。然而,尽管NiTi器械有许多优点,但它们在临床使用过程中可能会意外断裂,导致根管系统堵塞。本研究旨在评估冷冻治疗对Neoniti旋转锉抗骨折能力的影响。材料和方法:对20个尖端尺寸为#35、锥度为6%的Neoniti旋转锉进行了体外研究,分为两组(N=10)。对于低温处理,将锉刀浸入-196°C的液氮中24小时。接下来,对两组中的Neoniti锉刀在以20N/cm扭矩以500rpm操作的手持件中进行循环疲劳测试。旋转文件直到破裂,并记录每个文件的破裂时间和破裂周期数。两组通过独立t检验进行比较,显著性水平为0.05。结果:对照组骨折周期数为235700±50649.22,冷冻治疗组为280600±22979.21。对照组和冷冻治疗组的平均骨折时间分别为471.40±101.29和561.20±45.958秒。两组之间在两个变量上均存在显著差异(结论:根据我们的研究结果,使用低温治疗可以提高旋转器械的抗骨折能力,使其成为牙科临床医生采用的一种有益做法。通过使用低温治疗的旋转器械,临床医生可以潜在地降低牙科手术中锉刀骨折的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Cryotherapy on Fracture Resistance of Neoniti Rotary Instruments.

Objectives: Nickel-titanium (NiTi) rotary files were introduced to optimize root canal instrumentation in endodontic treatment. However, despite the numerous advantages of NiTi instruments, they may unexpectedly break during clinical use, resulting in obstruction of the root canal system. This investigation aimed to assess the effect of cryotherapy on fracture resistance of Neoniti rotary files. Materials and Methods: This in vitro, study was conducted on 20 Neoniti rotary files with #35 tip size and 6% taper in two groups with and without cryogenic treatment (N=10). For cryogenic treatment, the files were immersed in liquid nitrogen at -196°C for 24 hours. Next, the Neoniti files in both groups were subjected to cyclic fatigue testing in a hand-piece operating at 500 rpm with 20 N/cm torque. The files were rotated until fracture and the fracture time as well as the number of cycles to fracture were recorded for each file. The two groups were compared by independent t-test at 0.05 level of significance. Results: The number of cycles to fracture was 235700±50649.22 in the control and 280600±22979.21 in the cryotherapy group. The mean fracture time was 471.40±101.29 and 561.20±45.958 seconds in the control and cryotherapy groups, respectively. Significant differences in both variables were noted between the two groups (P<0.05). Conclusion: Based on our findings, utilizing cryogenic treatment may enhance the fracture resistance of rotary instruments, making it a beneficial practice for dental clinicians to adopt. By using cryogenically treated rotary instruments, clinicians can potentially reduce the risk of file fracture during dental procedures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Frontiers in Dentistry
Frontiers in Dentistry Dentistry-General Dentistry
CiteScore
1.00
自引率
0.00%
发文量
34
审稿时长
12 weeks
期刊最新文献
Anxiolytic Effect of Jasmine Aromatherapy in Pediatric Dental Procedures: A Single-Blinded Randomized Placebo-Controlled Trial. Smoking Cessation Counseling: Practices, Determinants, and Barriers in a Sample of Iranian Primary Care Dentists. Fracture Resistance, Surface Roughness, and Microtensile Bond Strength of Monolithic Zirconia to Resin Cements after Plasma Treatment. The Effect of Dimethyl Sulfoxide on the Microtensile Bond Strength of Universal Adhesives to Dentin. In Vitro Effects of Sof-Lex, Eve, and Astropol Polishing Systems on Composite Resin Surface Roughness after Aging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1