SUOH 03导丝用于冠状动脉夹层的治疗:来自多中心注册的见解。

IF 1.6 3区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of interventional cardiology Pub Date : 2023-01-01 DOI:10.1155/2023/7958808
Gabriele L Gasparini, Mario Bollati, Mauro Chiarito, Michele Cacia, Fausto Roccasalva, Claudiu Ungureanu, Giuseppe Colletti, Simone Muraglia, Pierluigi Merella, Fabrizio Ugo, Andrea Pacchioni, Salvatore Colangelo, Jorge Sanz Sanchez, Pier Pasquale Leone, Azeem Latib, Pietro Mazzarotto
{"title":"SUOH 03导丝用于冠状动脉夹层的治疗:来自多中心注册的见解。","authors":"Gabriele L Gasparini,&nbsp;Mario Bollati,&nbsp;Mauro Chiarito,&nbsp;Michele Cacia,&nbsp;Fausto Roccasalva,&nbsp;Claudiu Ungureanu,&nbsp;Giuseppe Colletti,&nbsp;Simone Muraglia,&nbsp;Pierluigi Merella,&nbsp;Fabrizio Ugo,&nbsp;Andrea Pacchioni,&nbsp;Salvatore Colangelo,&nbsp;Jorge Sanz Sanchez,&nbsp;Pier Pasquale Leone,&nbsp;Azeem Latib,&nbsp;Pietro Mazzarotto","doi":"10.1155/2023/7958808","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In the setting of coronary artery dissection, both spontaneous and iatrogenic, fixing the intimal tear, usually with stent implantation, can be extremely challenging if the distal wire position has been lost. Common complications are mainly related to the inadvertent subintimal tracking of the guidewire while attempting to gain the distal true lumen.</p><p><strong>Aims: </strong>To report the registry results of using the SUOH 0.3 guidewire for managing coronary artery dissection in a real-world multicenter setting.</p><p><strong>Methods: </strong>The study population in this retrospective, multicenter, international registry included 75 consecutive patients who underwent PCI and required an antegrade wiring of a dissected coronary artery.</p><p><strong>Results: </strong>Successful use of SUOH 0.3 was achieved in 69 (92%) patients. The use of a microcatheter was associated with a significantly higher rate of TIMI 3 flow at the end of the procedure (no microcatheter: <i>n</i> = 17, 81%; microcatheter: <i>n</i> = 52, 96.3%; <i>p</i> = 0.017). The first recanalization attempt was made with the SUOH 03 guidewire in 48 (64%) cases, and it was successful in 42 (87%). The overall PCI success rate was reported in 72 (96%) patients, with no significant differences among patients with different origins, mechanisms, and locations of dissection.</p><p><strong>Conclusions: </strong>In this setting, the SUOH 0.3 guidewire provides high procedural success without additional complex techniques.</p>","PeriodicalId":16329,"journal":{"name":"Journal of interventional cardiology","volume":"2023 ","pages":"7958808"},"PeriodicalIF":1.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10409579/pdf/","citationCount":"0","resultStr":"{\"title\":\"SUOH 03 Guidewire for the Management of Coronary Artery Dissection: Insights from a Multicenter Registry.\",\"authors\":\"Gabriele L Gasparini,&nbsp;Mario Bollati,&nbsp;Mauro Chiarito,&nbsp;Michele Cacia,&nbsp;Fausto Roccasalva,&nbsp;Claudiu Ungureanu,&nbsp;Giuseppe Colletti,&nbsp;Simone Muraglia,&nbsp;Pierluigi Merella,&nbsp;Fabrizio Ugo,&nbsp;Andrea Pacchioni,&nbsp;Salvatore Colangelo,&nbsp;Jorge Sanz Sanchez,&nbsp;Pier Pasquale Leone,&nbsp;Azeem Latib,&nbsp;Pietro Mazzarotto\",\"doi\":\"10.1155/2023/7958808\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>In the setting of coronary artery dissection, both spontaneous and iatrogenic, fixing the intimal tear, usually with stent implantation, can be extremely challenging if the distal wire position has been lost. Common complications are mainly related to the inadvertent subintimal tracking of the guidewire while attempting to gain the distal true lumen.</p><p><strong>Aims: </strong>To report the registry results of using the SUOH 0.3 guidewire for managing coronary artery dissection in a real-world multicenter setting.</p><p><strong>Methods: </strong>The study population in this retrospective, multicenter, international registry included 75 consecutive patients who underwent PCI and required an antegrade wiring of a dissected coronary artery.</p><p><strong>Results: </strong>Successful use of SUOH 0.3 was achieved in 69 (92%) patients. The use of a microcatheter was associated with a significantly higher rate of TIMI 3 flow at the end of the procedure (no microcatheter: <i>n</i> = 17, 81%; microcatheter: <i>n</i> = 52, 96.3%; <i>p</i> = 0.017). The first recanalization attempt was made with the SUOH 03 guidewire in 48 (64%) cases, and it was successful in 42 (87%). The overall PCI success rate was reported in 72 (96%) patients, with no significant differences among patients with different origins, mechanisms, and locations of dissection.</p><p><strong>Conclusions: </strong>In this setting, the SUOH 0.3 guidewire provides high procedural success without additional complex techniques.</p>\",\"PeriodicalId\":16329,\"journal\":{\"name\":\"Journal of interventional cardiology\",\"volume\":\"2023 \",\"pages\":\"7958808\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10409579/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of interventional cardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1155/2023/7958808\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of interventional cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/2023/7958808","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:在自发性和医源性冠状动脉剥离的情况下,如果远端金属丝位置丢失,固定内膜撕裂(通常采用支架植入)是极具挑战性的。常见的并发症主要与导丝在试图获得远端真腔时无意中在内膜下跟踪有关。目的:报告在真实世界的多中心环境中使用SUOH 0.3导丝治疗冠状动脉夹层的注册结果。方法:这项回顾性、多中心、国际登记的研究人群包括75名连续接受PCI治疗并需要顺行冠状动脉剥离的患者。结果:69例(92%)患者成功使用SUOH 0.3。在手术结束时,微导管的使用与更高的TIMI - 3血流率相关(无微导管:n = 17,81%;微导管:52例,占96.3%;p = 0.017)。48例(64%)患者使用SUOH 03导丝进行了第一次再通尝试,42例(87%)患者成功。报告了72例(96%)患者的PCI总成功率,不同来源、机制和解剖位置的患者之间无显著差异。结论:在这种情况下,SUOH 0.3导丝无需额外的复杂技术即可提供较高的手术成功率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SUOH 03 Guidewire for the Management of Coronary Artery Dissection: Insights from a Multicenter Registry.

Background: In the setting of coronary artery dissection, both spontaneous and iatrogenic, fixing the intimal tear, usually with stent implantation, can be extremely challenging if the distal wire position has been lost. Common complications are mainly related to the inadvertent subintimal tracking of the guidewire while attempting to gain the distal true lumen.

Aims: To report the registry results of using the SUOH 0.3 guidewire for managing coronary artery dissection in a real-world multicenter setting.

Methods: The study population in this retrospective, multicenter, international registry included 75 consecutive patients who underwent PCI and required an antegrade wiring of a dissected coronary artery.

Results: Successful use of SUOH 0.3 was achieved in 69 (92%) patients. The use of a microcatheter was associated with a significantly higher rate of TIMI 3 flow at the end of the procedure (no microcatheter: n = 17, 81%; microcatheter: n = 52, 96.3%; p = 0.017). The first recanalization attempt was made with the SUOH 03 guidewire in 48 (64%) cases, and it was successful in 42 (87%). The overall PCI success rate was reported in 72 (96%) patients, with no significant differences among patients with different origins, mechanisms, and locations of dissection.

Conclusions: In this setting, the SUOH 0.3 guidewire provides high procedural success without additional complex techniques.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of interventional cardiology
Journal of interventional cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.80
自引率
0.00%
发文量
81
审稿时长
6-12 weeks
期刊介绍: Journal of Interventional Cardiology is a peer-reviewed, Open Access journal that provides a forum for cardiologists determined to stay current in the diagnosis, investigation, and management of patients with cardiovascular disease and its associated complications. The journal publishes original research articles, review articles, and clinical studies focusing on new procedures and techniques in all major subject areas in the field, including: Acute coronary syndrome Coronary disease Congenital heart diseases Myocardial infarction Peripheral arterial disease Valvular heart disease Cardiac hemodynamics and physiology Haemostasis and thrombosis
期刊最新文献
Epidemiological Trends, Etiology, and Burden Study of Heart Failure in China, 1990–2019 A Comparative Analysis of Primary and Bailout ADR in CTO-PCI The Effect of Electromagnetic Interference Produced by Smartphones Using 5G Network on Patients With Permanent Pacemakers (EMS5G-PPM Study) Comparison of Sheathless and Sheathed Guiding Catheters in Transradial Percutaneous Coronary Interventions: A Systematic Review and Meta-Analysis Percutaneous Coronary Intervention Using the DynamX Sirolimus-Eluting Bioadaptor: 12-Month Clinical and Imaging Outcomes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1