对用于测定分析样本中硒含量的选定预浓缩技术进行严格审查。

IF 4.2 2区 化学 Q1 CHEMISTRY, ANALYTICAL Critical reviews in analytical chemistry Pub Date : 2024-01-01 Epub Date: 2022-12-08 DOI:10.1080/10408347.2022.2153579
Ebaa Adnan Azooz, Mustafa Tuzen, Wael I Mortada, Naeem Ullah
{"title":"对用于测定分析样本中硒含量的选定预浓缩技术进行严格审查。","authors":"Ebaa Adnan Azooz, Mustafa Tuzen, Wael I Mortada, Naeem Ullah","doi":"10.1080/10408347.2022.2153579","DOIUrl":null,"url":null,"abstract":"<p><p>Selenium (Se) is considered to be an essential trace element needed for all living organisms. The importance, deficiency, and toxic effects of Se mainly depend on its quantity and chemical nature. It has been observed that the inorganic versions of Se are more hazardous than the organic versions. This review is mainly focused on the application of different extraction methods used for Se extraction and determination such as microextraction, solid-phase extraction (SPE), and their modified modes in the last 12 years. The use of different dispersive medium (magnetic field, ultrasonic radiation, and vortex agitator) to enhance Se separation is also part of this review. The usage of environmentally friendly solvents such as supramolecular solvents, hydrophobic deep eutectic solvents (DESs), and ionic liquids (ILs) are also the focus of attention in this review. This review is also emphasized the application of advanced microextraction methods, particularly liquid-phase microextraction (LPME). The most recent advances in LPME extraction techniques for Se in various environmental samples, as well as their prospects, are reviewed. Additionally, a summary of cheap, simple, and accurate techniques that have not yet been used to determine small amounts of Se has been provided.</p>","PeriodicalId":10744,"journal":{"name":"Critical reviews in analytical chemistry","volume":" ","pages":"2072-2086"},"PeriodicalIF":4.2000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A critical review of selected preconcentration techniques used for selenium determination in analytical samples.\",\"authors\":\"Ebaa Adnan Azooz, Mustafa Tuzen, Wael I Mortada, Naeem Ullah\",\"doi\":\"10.1080/10408347.2022.2153579\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Selenium (Se) is considered to be an essential trace element needed for all living organisms. The importance, deficiency, and toxic effects of Se mainly depend on its quantity and chemical nature. It has been observed that the inorganic versions of Se are more hazardous than the organic versions. This review is mainly focused on the application of different extraction methods used for Se extraction and determination such as microextraction, solid-phase extraction (SPE), and their modified modes in the last 12 years. The use of different dispersive medium (magnetic field, ultrasonic radiation, and vortex agitator) to enhance Se separation is also part of this review. The usage of environmentally friendly solvents such as supramolecular solvents, hydrophobic deep eutectic solvents (DESs), and ionic liquids (ILs) are also the focus of attention in this review. This review is also emphasized the application of advanced microextraction methods, particularly liquid-phase microextraction (LPME). The most recent advances in LPME extraction techniques for Se in various environmental samples, as well as their prospects, are reviewed. Additionally, a summary of cheap, simple, and accurate techniques that have not yet been used to determine small amounts of Se has been provided.</p>\",\"PeriodicalId\":10744,\"journal\":{\"name\":\"Critical reviews in analytical chemistry\",\"volume\":\" \",\"pages\":\"2072-2086\"},\"PeriodicalIF\":4.2000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Critical reviews in analytical chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1080/10408347.2022.2153579\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/12/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical reviews in analytical chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1080/10408347.2022.2153579","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/12/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

硒(Se)被认为是所有生物体所必需的微量元素。硒的重要性、缺乏症和毒性作用主要取决于其数量和化学性质。据观察,无机硒比有机硒危害更大。本综述主要关注过去 12 年中用于萃取和测定硒的不同萃取方法的应用,如微萃取、固相萃取(SPE)及其改进模式。使用不同的分散介质(磁场、超声波辐射和涡流搅拌器)来提高硒的分离效果也是本综述的一部分。超分子溶剂、疏水性深共晶溶剂(DES)和离子液体(IL)等环境友好型溶剂的使用也是本综述关注的重点。本综述还强调了先进微萃取方法的应用,特别是液相微萃取(LPME)。综述了针对各种环境样品中的硒的 LPME 萃取技术的最新进展及其前景。此外,还概述了尚未用于测定少量硒的廉价、简单而准确的技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A critical review of selected preconcentration techniques used for selenium determination in analytical samples.

Selenium (Se) is considered to be an essential trace element needed for all living organisms. The importance, deficiency, and toxic effects of Se mainly depend on its quantity and chemical nature. It has been observed that the inorganic versions of Se are more hazardous than the organic versions. This review is mainly focused on the application of different extraction methods used for Se extraction and determination such as microextraction, solid-phase extraction (SPE), and their modified modes in the last 12 years. The use of different dispersive medium (magnetic field, ultrasonic radiation, and vortex agitator) to enhance Se separation is also part of this review. The usage of environmentally friendly solvents such as supramolecular solvents, hydrophobic deep eutectic solvents (DESs), and ionic liquids (ILs) are also the focus of attention in this review. This review is also emphasized the application of advanced microextraction methods, particularly liquid-phase microextraction (LPME). The most recent advances in LPME extraction techniques for Se in various environmental samples, as well as their prospects, are reviewed. Additionally, a summary of cheap, simple, and accurate techniques that have not yet been used to determine small amounts of Se has been provided.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
12.00
自引率
4.00%
发文量
137
审稿时长
6 months
期刊介绍: Critical Reviews in Analytical Chemistry continues to be a dependable resource for both the expert and the student by providing in-depth, scholarly, insightful reviews of important topics within the discipline of analytical chemistry and related measurement sciences. The journal exclusively publishes review articles that illuminate the underlying science, that evaluate the field''s status by putting recent developments into proper perspective and context, and that speculate on possible future developments. A limited number of articles are of a "tutorial" format written by experts for scientists seeking introduction or clarification in a new area. This journal serves as a forum for linking various underlying components in broad and interdisciplinary means, while maintaining balance between applied and fundamental research. Topics we are interested in receiving reviews on are the following: · chemical analysis; · instrumentation; · chemometrics; · analytical biochemistry; · medicinal analysis; · forensics; · environmental sciences; · applied physics; · and material science.
期刊最新文献
Fluorescence chemosensing and bioimaging of metal ions using schiff base probes working through photo-induced electron transfer (PET). Decoding the Challenges: navigating Intact Peptide Mass Spectrometry-Based Analysis for Biological Applications. Phytosterols in Plant-Derived Foods: Recent Updates in Extraction and Analysis Methods. Comprehensive Application and Prospects of Surface-Enhanced Raman Spectroscopy in Natural Product Research. Electroanalysis of Statin Drugs: A Review on the Electrochemical Sensor Architectures Ranging from Classical to Modern Systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1