Meagan K Brucker-Hahn, Hans J Zander, Andrew J Will, Jayesh C Vallabh, Jason S Wolff, David A Dinsmoor, Scott F Lempka
{"title":"脊髓刺激过程中诱发的复合动作电位:姿势和脉冲宽度对脊髓内信号特征和神经激活的影响。","authors":"Meagan K Brucker-Hahn, Hans J Zander, Andrew J Will, Jayesh C Vallabh, Jason S Wolff, David A Dinsmoor, Scott F Lempka","doi":"10.1088/1741-2552/aceca4","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Evoked compound action potential (ECAP) recordings have emerged as a quantitative measure of the neural response during spinal cord stimulation (SCS) to treat pain. However, utilization of ECAP recordings to optimize stimulation efficacy requires an understanding of the factors influencing these recordings and their relationship to the underlying neural activation.<i>Approach.</i>We acquired a library of ECAP recordings from 56 patients over a wide assortment of postures and stimulation parameters, and then processed these signals to quantify several aspects of these recordings (e.g., ECAP threshold (ET), amplitude, latency, growth rate). We compared our experimental findings against a computational model that examined the effect of variable distances between the spinal cord and the SCS electrodes.<i>Main results.</i>Postural shifts strongly influenced the experimental ECAP recordings, with a 65.7% lower ET and 178.5% higher growth rate when supine versus seated. The computational model exhibited similar trends, with a 71.9% lower ET and 231.5% higher growth rate for a 2.0 mm cerebrospinal fluid (CSF) layer (representing a supine posture) versus a 4.4 mm CSF layer (representing a prone posture). Furthermore, the computational model demonstrated that constant ECAP amplitudes may not equate to a constant degree of neural activation.<i>Significance.</i>These results demonstrate large variability across all ECAP metrics and the inability of a constant ECAP amplitude to provide constant neural activation. These results are critical to improve the delivery, efficacy, and robustness of clinical SCS technologies utilizing these ECAP recordings to provide closed-loop stimulation.</p>","PeriodicalId":16753,"journal":{"name":"Journal of neural engineering","volume":"20 4","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2023-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Evoked compound action potentials during spinal cord stimulation: effects of posture and pulse width on signal features and neural activation within the spinal cord.\",\"authors\":\"Meagan K Brucker-Hahn, Hans J Zander, Andrew J Will, Jayesh C Vallabh, Jason S Wolff, David A Dinsmoor, Scott F Lempka\",\"doi\":\"10.1088/1741-2552/aceca4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><i>Objective.</i>Evoked compound action potential (ECAP) recordings have emerged as a quantitative measure of the neural response during spinal cord stimulation (SCS) to treat pain. However, utilization of ECAP recordings to optimize stimulation efficacy requires an understanding of the factors influencing these recordings and their relationship to the underlying neural activation.<i>Approach.</i>We acquired a library of ECAP recordings from 56 patients over a wide assortment of postures and stimulation parameters, and then processed these signals to quantify several aspects of these recordings (e.g., ECAP threshold (ET), amplitude, latency, growth rate). We compared our experimental findings against a computational model that examined the effect of variable distances between the spinal cord and the SCS electrodes.<i>Main results.</i>Postural shifts strongly influenced the experimental ECAP recordings, with a 65.7% lower ET and 178.5% higher growth rate when supine versus seated. The computational model exhibited similar trends, with a 71.9% lower ET and 231.5% higher growth rate for a 2.0 mm cerebrospinal fluid (CSF) layer (representing a supine posture) versus a 4.4 mm CSF layer (representing a prone posture). Furthermore, the computational model demonstrated that constant ECAP amplitudes may not equate to a constant degree of neural activation.<i>Significance.</i>These results demonstrate large variability across all ECAP metrics and the inability of a constant ECAP amplitude to provide constant neural activation. These results are critical to improve the delivery, efficacy, and robustness of clinical SCS technologies utilizing these ECAP recordings to provide closed-loop stimulation.</p>\",\"PeriodicalId\":16753,\"journal\":{\"name\":\"Journal of neural engineering\",\"volume\":\"20 4\",\"pages\":\"\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2023-08-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of neural engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1088/1741-2552/aceca4\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neural engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1741-2552/aceca4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Evoked compound action potentials during spinal cord stimulation: effects of posture and pulse width on signal features and neural activation within the spinal cord.
Objective.Evoked compound action potential (ECAP) recordings have emerged as a quantitative measure of the neural response during spinal cord stimulation (SCS) to treat pain. However, utilization of ECAP recordings to optimize stimulation efficacy requires an understanding of the factors influencing these recordings and their relationship to the underlying neural activation.Approach.We acquired a library of ECAP recordings from 56 patients over a wide assortment of postures and stimulation parameters, and then processed these signals to quantify several aspects of these recordings (e.g., ECAP threshold (ET), amplitude, latency, growth rate). We compared our experimental findings against a computational model that examined the effect of variable distances between the spinal cord and the SCS electrodes.Main results.Postural shifts strongly influenced the experimental ECAP recordings, with a 65.7% lower ET and 178.5% higher growth rate when supine versus seated. The computational model exhibited similar trends, with a 71.9% lower ET and 231.5% higher growth rate for a 2.0 mm cerebrospinal fluid (CSF) layer (representing a supine posture) versus a 4.4 mm CSF layer (representing a prone posture). Furthermore, the computational model demonstrated that constant ECAP amplitudes may not equate to a constant degree of neural activation.Significance.These results demonstrate large variability across all ECAP metrics and the inability of a constant ECAP amplitude to provide constant neural activation. These results are critical to improve the delivery, efficacy, and robustness of clinical SCS technologies utilizing these ECAP recordings to provide closed-loop stimulation.
期刊介绍:
The goal of Journal of Neural Engineering (JNE) is to act as a forum for the interdisciplinary field of neural engineering where neuroscientists, neurobiologists and engineers can publish their work in one periodical that bridges the gap between neuroscience and engineering. The journal publishes articles in the field of neural engineering at the molecular, cellular and systems levels.
The scope of the journal encompasses experimental, computational, theoretical, clinical and applied aspects of: Innovative neurotechnology; Brain-machine (computer) interface; Neural interfacing; Bioelectronic medicines; Neuromodulation; Neural prostheses; Neural control; Neuro-rehabilitation; Neurorobotics; Optical neural engineering; Neural circuits: artificial & biological; Neuromorphic engineering; Neural tissue regeneration; Neural signal processing; Theoretical and computational neuroscience; Systems neuroscience; Translational neuroscience; Neuroimaging.