{"title":"利用光参量放大进行探测的非线性光学成像(特邀论文)。","authors":"Yi Sun, Haohua Tu, Stephen A Boppart","doi":"10.1142/s1793545822450018","DOIUrl":null,"url":null,"abstract":"<p><p>Nonlinear optical imaging is a versatile tool that has been proven to be exceptionally useful in various research fields. However, due to the use of photomultiplier tubes (PMTs), the wide application of nonlinear optical imaging is limited by the incapability of imaging under ambient light. In this paper, we propose and demonstrate a new optical imaging detection method based on optical parametric amplification (OPA). As a nonlinear optical process, OPA intrinsically rejects ambient light photons by coherence gating. Periodical poled lithium niobate (PPLN) crystals are used in this study as the media for OPA. Compared to bulk nonlinear optical crystals, PPLN crystals support the generation of OPA signal with lower pump power. Therefore, this characteristic of PPLN crystals is particularly beneficial when using high-repetition-rate lasers, which facilitate high-speed optical signal detection, such as in spectroscopy and imaging. A PPLN-based OPA system was built to amplify the emitted imaging signal from second harmonic generation (SHG) and coherent anti-Stokes Raman scattering (CARS) microscopy imaging, and the amplified optical signal was strong enough to be detected by a biased photodiode under ordinary room light conditions. With OPA detection, ambient-light-on SHG and CARS imaging becomes possible, and achieves a similar result as PMT detection under strictly dark environments. These results demonstrate that OPA can be used as a substitute for PMTs in nonlinear optical imaging to adapt it to various applications with complex lighting conditions.</p>","PeriodicalId":16248,"journal":{"name":"Journal of Innovative Optical Health Sciences","volume":"16 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10426456/pdf/","citationCount":"0","resultStr":"{\"title\":\"Nonlinear optical imaging by detection with optical parametric amplification (invited paper).\",\"authors\":\"Yi Sun, Haohua Tu, Stephen A Boppart\",\"doi\":\"10.1142/s1793545822450018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Nonlinear optical imaging is a versatile tool that has been proven to be exceptionally useful in various research fields. However, due to the use of photomultiplier tubes (PMTs), the wide application of nonlinear optical imaging is limited by the incapability of imaging under ambient light. In this paper, we propose and demonstrate a new optical imaging detection method based on optical parametric amplification (OPA). As a nonlinear optical process, OPA intrinsically rejects ambient light photons by coherence gating. Periodical poled lithium niobate (PPLN) crystals are used in this study as the media for OPA. Compared to bulk nonlinear optical crystals, PPLN crystals support the generation of OPA signal with lower pump power. Therefore, this characteristic of PPLN crystals is particularly beneficial when using high-repetition-rate lasers, which facilitate high-speed optical signal detection, such as in spectroscopy and imaging. A PPLN-based OPA system was built to amplify the emitted imaging signal from second harmonic generation (SHG) and coherent anti-Stokes Raman scattering (CARS) microscopy imaging, and the amplified optical signal was strong enough to be detected by a biased photodiode under ordinary room light conditions. With OPA detection, ambient-light-on SHG and CARS imaging becomes possible, and achieves a similar result as PMT detection under strictly dark environments. These results demonstrate that OPA can be used as a substitute for PMTs in nonlinear optical imaging to adapt it to various applications with complex lighting conditions.</p>\",\"PeriodicalId\":16248,\"journal\":{\"name\":\"Journal of Innovative Optical Health Sciences\",\"volume\":\"16 1\",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10426456/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Innovative Optical Health Sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1142/s1793545822450018\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/11/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Innovative Optical Health Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1142/s1793545822450018","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/11/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPTICS","Score":null,"Total":0}
Nonlinear optical imaging by detection with optical parametric amplification (invited paper).
Nonlinear optical imaging is a versatile tool that has been proven to be exceptionally useful in various research fields. However, due to the use of photomultiplier tubes (PMTs), the wide application of nonlinear optical imaging is limited by the incapability of imaging under ambient light. In this paper, we propose and demonstrate a new optical imaging detection method based on optical parametric amplification (OPA). As a nonlinear optical process, OPA intrinsically rejects ambient light photons by coherence gating. Periodical poled lithium niobate (PPLN) crystals are used in this study as the media for OPA. Compared to bulk nonlinear optical crystals, PPLN crystals support the generation of OPA signal with lower pump power. Therefore, this characteristic of PPLN crystals is particularly beneficial when using high-repetition-rate lasers, which facilitate high-speed optical signal detection, such as in spectroscopy and imaging. A PPLN-based OPA system was built to amplify the emitted imaging signal from second harmonic generation (SHG) and coherent anti-Stokes Raman scattering (CARS) microscopy imaging, and the amplified optical signal was strong enough to be detected by a biased photodiode under ordinary room light conditions. With OPA detection, ambient-light-on SHG and CARS imaging becomes possible, and achieves a similar result as PMT detection under strictly dark environments. These results demonstrate that OPA can be used as a substitute for PMTs in nonlinear optical imaging to adapt it to various applications with complex lighting conditions.
期刊介绍:
JIOHS serves as an international forum for the publication of the latest developments in all areas of photonics in biology and medicine. JIOHS will consider for publication original papers in all disciplines of photonics in biology and medicine, including but not limited to:
-Photonic therapeutics and diagnostics-
Optical clinical technologies and systems-
Tissue optics-
Laser-tissue interaction and tissue engineering-
Biomedical spectroscopy-
Advanced microscopy and imaging-
Nanobiophotonics and optical molecular imaging-
Multimodal and hybrid biomedical imaging-
Micro/nanofabrication-
Medical microsystems-
Optical coherence tomography-
Photodynamic therapy.
JIOHS provides a vehicle to help professionals, graduates, engineers, academics and researchers working in the field of intelligent photonics in biology and medicine to disseminate information on the state-of-the-art technique.