{"title":"电解质溶液介电弛豫光谱的时域反射计","authors":"R. Buchner, J. Barthel","doi":"10.1002/bbpc.199700014","DOIUrl":null,"url":null,"abstract":"<p>A time domain reflectometer for dielectric relaxation spectroscopy of electrolyte solutions in the temperature range of −;45 ≤ ϑ /°C ≤ 90 is presented. With a set of cutoff cells differing in their cell constants, pure solvents covering the permittivity range of 7 ≤ ϵ ≤ 228 and their concentrated electrolyte solutions (κ > 1 Ω<sup>−1</sup> m<sup>−1</sup>) can be investigated at frequencies of 0.05 ≤ v/GHz ≤ 9. In combination with the transmission line system of our laboratory (8.5 ≤ v/GHz ≤ 89) dielectric dispersion, ϵ′(<i>v</i>), and total loss, η″(<i>v</i>) = <i>ϵ″</i>(<i>v</i>) + κ/(2π <i>vϵ</i><sub>0</sub>) can be determined with 2% accuracy relative to ϵ.</p>","PeriodicalId":100156,"journal":{"name":"Berichte der Bunsengesellschaft für physikalische Chemie","volume":"101 10","pages":"1509-1516"},"PeriodicalIF":0.0000,"publicationDate":"2014-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/bbpc.199700014","citationCount":"32","resultStr":"{\"title\":\"A Time Domain Reflectometer for Dielectric Relaxation Spectroscopy of Electrolyte Solutions\",\"authors\":\"R. Buchner, J. Barthel\",\"doi\":\"10.1002/bbpc.199700014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A time domain reflectometer for dielectric relaxation spectroscopy of electrolyte solutions in the temperature range of −;45 ≤ ϑ /°C ≤ 90 is presented. With a set of cutoff cells differing in their cell constants, pure solvents covering the permittivity range of 7 ≤ ϵ ≤ 228 and their concentrated electrolyte solutions (κ > 1 Ω<sup>−1</sup> m<sup>−1</sup>) can be investigated at frequencies of 0.05 ≤ v/GHz ≤ 9. In combination with the transmission line system of our laboratory (8.5 ≤ v/GHz ≤ 89) dielectric dispersion, ϵ′(<i>v</i>), and total loss, η″(<i>v</i>) = <i>ϵ″</i>(<i>v</i>) + κ/(2π <i>vϵ</i><sub>0</sub>) can be determined with 2% accuracy relative to ϵ.</p>\",\"PeriodicalId\":100156,\"journal\":{\"name\":\"Berichte der Bunsengesellschaft für physikalische Chemie\",\"volume\":\"101 10\",\"pages\":\"1509-1516\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-03-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/bbpc.199700014\",\"citationCount\":\"32\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Berichte der Bunsengesellschaft für physikalische Chemie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/bbpc.199700014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Berichte der Bunsengesellschaft für physikalische Chemie","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bbpc.199700014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Time Domain Reflectometer for Dielectric Relaxation Spectroscopy of Electrolyte Solutions
A time domain reflectometer for dielectric relaxation spectroscopy of electrolyte solutions in the temperature range of −;45 ≤ ϑ /°C ≤ 90 is presented. With a set of cutoff cells differing in their cell constants, pure solvents covering the permittivity range of 7 ≤ ϵ ≤ 228 and their concentrated electrolyte solutions (κ > 1 Ω−1 m−1) can be investigated at frequencies of 0.05 ≤ v/GHz ≤ 9. In combination with the transmission line system of our laboratory (8.5 ≤ v/GHz ≤ 89) dielectric dispersion, ϵ′(v), and total loss, η″(v) = ϵ″(v) + κ/(2π vϵ0) can be determined with 2% accuracy relative to ϵ.