小儿下颌骨骨折的可吸收固定与钛刚性固定:系统回顾、机构经验和比较分析。

IF 0.8 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Craniomaxillofacial Trauma & Reconstruction Pub Date : 2022-09-01 Epub Date: 2021-06-21 DOI:10.1177/19433875211022573
Matthew E Pontell, Eva B Niklinska, Stephane A Braun, Nolan Jaeger, Kevin J Kelly, Michael S Golinko
{"title":"小儿下颌骨骨折的可吸收固定与钛刚性固定:系统回顾、机构经验和比较分析。","authors":"Matthew E Pontell, Eva B Niklinska, Stephane A Braun, Nolan Jaeger, Kevin J Kelly, Michael S Golinko","doi":"10.1177/19433875211022573","DOIUrl":null,"url":null,"abstract":"<p><strong>Study design: </strong>Pediatric mandible fractures mandate special consideration because of unerupted teeth, mixed dentition, facial growth and the inability to tolerate maxillomandibular fixation. No consensus exists as to whether resorbable or titanium plating systems are superior with regards to clinical outcomes.</p><p><strong>Objective: </strong>This study aims to systematically review and compare the outcomes of both material types in the treatment of pediatric mandible fractures.</p><p><strong>Methods: </strong>After PROSPERO registration, studies from 1990-2020 publishing on outcomes of ORIF of pediatric mandible fractures were systematically reviewed according to PRISMA guidelines. An additional retrospective review was conducted at a pediatric level 1 trauma center.</p><p><strong>Results: </strong>1,144 patients met inclusion criteria (30.5% resorbable vs. 69.5% titanium). Total complication rate was 13%, and 10% required a second, unplanned operation. Complication rates in the titanium and resorbable groups were not significantly different (14% vs. 10%; P = 0.07), and titanium hardware was more frequently removed on an elective basis (P < 0.001). Condylar/sub-condylar fractures were more often treated with resorbable hardware (P = 0.01); whereas angle fractures were more often treated with titanium hardware (P < 0.001). Within both cohorts, fracture type did not increase the risk of complications, and comparison between groups by anatomic level did not demonstrate any significant difference in complications.</p><p><strong>Conclusions: </strong>Pediatric mandible fractures requiring ORIF are rare, and hardware-specific outcomes data is scarce. This study suggests that titanium and resorbable plating systems are equally safe, but titanium hardware often requires surgical removal. Surgical approach should be tailored by fracture anatomy, age-related concerns and surgeon preference.</p>","PeriodicalId":46447,"journal":{"name":"Craniomaxillofacial Trauma & Reconstruction","volume":"15 3","pages":"189-200"},"PeriodicalIF":0.8000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9446277/pdf/10.1177_19433875211022573.pdf","citationCount":"0","resultStr":"{\"title\":\"Resorbable Versus Titanium Rigid Fixation for Pediatric Mandibular Fractures: A Systematic Review, Institutional Experience and Comparative Analysis.\",\"authors\":\"Matthew E Pontell, Eva B Niklinska, Stephane A Braun, Nolan Jaeger, Kevin J Kelly, Michael S Golinko\",\"doi\":\"10.1177/19433875211022573\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Study design: </strong>Pediatric mandible fractures mandate special consideration because of unerupted teeth, mixed dentition, facial growth and the inability to tolerate maxillomandibular fixation. No consensus exists as to whether resorbable or titanium plating systems are superior with regards to clinical outcomes.</p><p><strong>Objective: </strong>This study aims to systematically review and compare the outcomes of both material types in the treatment of pediatric mandible fractures.</p><p><strong>Methods: </strong>After PROSPERO registration, studies from 1990-2020 publishing on outcomes of ORIF of pediatric mandible fractures were systematically reviewed according to PRISMA guidelines. An additional retrospective review was conducted at a pediatric level 1 trauma center.</p><p><strong>Results: </strong>1,144 patients met inclusion criteria (30.5% resorbable vs. 69.5% titanium). Total complication rate was 13%, and 10% required a second, unplanned operation. Complication rates in the titanium and resorbable groups were not significantly different (14% vs. 10%; P = 0.07), and titanium hardware was more frequently removed on an elective basis (P < 0.001). Condylar/sub-condylar fractures were more often treated with resorbable hardware (P = 0.01); whereas angle fractures were more often treated with titanium hardware (P < 0.001). Within both cohorts, fracture type did not increase the risk of complications, and comparison between groups by anatomic level did not demonstrate any significant difference in complications.</p><p><strong>Conclusions: </strong>Pediatric mandible fractures requiring ORIF are rare, and hardware-specific outcomes data is scarce. This study suggests that titanium and resorbable plating systems are equally safe, but titanium hardware often requires surgical removal. Surgical approach should be tailored by fracture anatomy, age-related concerns and surgeon preference.</p>\",\"PeriodicalId\":46447,\"journal\":{\"name\":\"Craniomaxillofacial Trauma & Reconstruction\",\"volume\":\"15 3\",\"pages\":\"189-200\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2022-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9446277/pdf/10.1177_19433875211022573.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Craniomaxillofacial Trauma & Reconstruction\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/19433875211022573\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/6/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Craniomaxillofacial Trauma & Reconstruction","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19433875211022573","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/6/21 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究设计:小儿下颌骨骨折需要特别考虑,因为小儿的牙齿尚未长齐、牙列不齐、面部发育不良,而且无法耐受上下颌骨固定。就临床效果而言,可吸收钢板系统还是钛钢板系统更胜一筹,目前尚无共识:本研究旨在系统回顾和比较两种材料在治疗小儿下颌骨骨折中的效果:方法:在 PROSPERO 注册后,根据 PRISMA 指南对 1990-2020 年间发表的有关小儿下颌骨骨折 ORIF 治疗效果的研究进行了系统回顾。结果:1144名患者符合纳入标准:1144名患者符合纳入标准(30.5%为可吸收假体,69.5%为钛假体)。总并发症发生率为 13%,10% 的患者需要进行第二次意外手术。钛合金组和可吸收组的并发症发生率无显著差异(14% vs. 10%;P = 0.07),钛合金硬件更常被选择性移除(P < 0.001)。髁状/髁下骨折更多采用可吸收硬件治疗(P = 0.01);而角骨折更多采用钛合金硬件治疗(P < 0.001)。在这两个组别中,骨折类型并不会增加并发症的风险,而按解剖层次进行的组间比较也未显示出并发症方面的显著差异:结论:需要进行手术切除治疗的小儿下颌骨骨折非常罕见,而特定硬件的结果数据却很少。这项研究表明,钛合金和可吸收钢板系统同样安全,但钛合金硬件通常需要手术移除。手术方法应根据骨折解剖结构、与年龄相关的问题和外科医生的偏好而定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Resorbable Versus Titanium Rigid Fixation for Pediatric Mandibular Fractures: A Systematic Review, Institutional Experience and Comparative Analysis.

Study design: Pediatric mandible fractures mandate special consideration because of unerupted teeth, mixed dentition, facial growth and the inability to tolerate maxillomandibular fixation. No consensus exists as to whether resorbable or titanium plating systems are superior with regards to clinical outcomes.

Objective: This study aims to systematically review and compare the outcomes of both material types in the treatment of pediatric mandible fractures.

Methods: After PROSPERO registration, studies from 1990-2020 publishing on outcomes of ORIF of pediatric mandible fractures were systematically reviewed according to PRISMA guidelines. An additional retrospective review was conducted at a pediatric level 1 trauma center.

Results: 1,144 patients met inclusion criteria (30.5% resorbable vs. 69.5% titanium). Total complication rate was 13%, and 10% required a second, unplanned operation. Complication rates in the titanium and resorbable groups were not significantly different (14% vs. 10%; P = 0.07), and titanium hardware was more frequently removed on an elective basis (P < 0.001). Condylar/sub-condylar fractures were more often treated with resorbable hardware (P = 0.01); whereas angle fractures were more often treated with titanium hardware (P < 0.001). Within both cohorts, fracture type did not increase the risk of complications, and comparison between groups by anatomic level did not demonstrate any significant difference in complications.

Conclusions: Pediatric mandible fractures requiring ORIF are rare, and hardware-specific outcomes data is scarce. This study suggests that titanium and resorbable plating systems are equally safe, but titanium hardware often requires surgical removal. Surgical approach should be tailored by fracture anatomy, age-related concerns and surgeon preference.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Craniomaxillofacial Trauma & Reconstruction
Craniomaxillofacial Trauma & Reconstruction DENTISTRY, ORAL SURGERY & MEDICINE-
自引率
0.00%
发文量
39
期刊最新文献
Guidelines for Orbital Defect Assessment and Patient-Specific Implant Design: Introducing OA2 (Orbital Assessment Algorithm). Moving Forward: The Last Subscription Issue and the Dawn of Open Access. Opportunity Cost of Surgical Management of Craniomaxillofacial Trauma: A Longitudinal Study. Does More Invasive Surgery Result in Higher Patient Satisfaction? A Long-Term Follow-Up of 136 Zygomaticomaxillary Complex Fractures. Microvascular Reconstructions in Elderly Patients With Oral Squamous Cell Carcinoma - Too Old for Surgical Treatment?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1