{"title":"Savi Scout雷达定位:从传统的有线定位到无线技术的转变","authors":"Gopal R. Vijayaraghavan ,&nbsp;Connie Ge ,&nbsp;Amanda Lee ,&nbsp;John G. Roubil ,&nbsp;Dina H. Kandil ,&nbsp;Kate H. Dinh ,&nbsp;Srinivasan Vedantham","doi":"10.1053/j.sult.2022.10.004","DOIUrl":null,"url":null,"abstract":"<div><p>Breast-conserving surgery or lumpectomy<span><span> requires localization of the lesion prior to surgery, which is traditionally accomplished by imaging-guided wire localization. Over the last decade, alternatives to wire localization have emerged. This work reviews the literature on one such wireless technology, SaviScout radar (SSR) system, and shares our experience with using this technology for presurgical tumor localization. The SSR surgical guidance system is non-radioactive. The radiologist implants a reflector device in the breast under </span>mammography or ultrasound guidance at any time prior to surgery. The placement of this reflector can be confirmed from the cadence of a handheld percutaneous probe of a handpiece and console system. Results from several studies show that the surgical outcomes from SSR and wire-localization are similar. SSR provides operational advantages as the scheduling for reflector placement by radiologists is decoupled from surgery, but at an increased cost compared to wire-localization.</span></p></div>","PeriodicalId":49541,"journal":{"name":"Seminars in Ultrasound Ct and Mri","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Savi-Scout Radar Localization: Transitioning From the Traditional Wire Localization to Wireless Technology for Surgical Guidance at Lumpectomies\",\"authors\":\"Gopal R. Vijayaraghavan ,&nbsp;Connie Ge ,&nbsp;Amanda Lee ,&nbsp;John G. Roubil ,&nbsp;Dina H. Kandil ,&nbsp;Kate H. Dinh ,&nbsp;Srinivasan Vedantham\",\"doi\":\"10.1053/j.sult.2022.10.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Breast-conserving surgery or lumpectomy<span><span> requires localization of the lesion prior to surgery, which is traditionally accomplished by imaging-guided wire localization. Over the last decade, alternatives to wire localization have emerged. This work reviews the literature on one such wireless technology, SaviScout radar (SSR) system, and shares our experience with using this technology for presurgical tumor localization. The SSR surgical guidance system is non-radioactive. The radiologist implants a reflector device in the breast under </span>mammography or ultrasound guidance at any time prior to surgery. The placement of this reflector can be confirmed from the cadence of a handheld percutaneous probe of a handpiece and console system. Results from several studies show that the surgical outcomes from SSR and wire-localization are similar. SSR provides operational advantages as the scheduling for reflector placement by radiologists is decoupled from surgery, but at an increased cost compared to wire-localization.</span></p></div>\",\"PeriodicalId\":49541,\"journal\":{\"name\":\"Seminars in Ultrasound Ct and Mri\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Seminars in Ultrasound Ct and Mri\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0887217122000786\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in Ultrasound Ct and Mri","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0887217122000786","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 1

摘要

保乳手术或肿块切除术需要在手术前对病变进行定位,传统上是通过成像引导下的金属丝定位来完成的。在过去的十年里,出现了导线本地化的替代方案。这项工作回顾了关于SaviScott雷达(SSR)系统这一无线技术的文献,并分享了我们使用该技术进行术前肿瘤定位的经验。SSR手术引导系统是非放射性的。放射科医生在手术前的任何时候,在乳房X光检查或超声引导下,在乳房中植入反射装置。该反射器的放置可以通过手持件和控制台系统的手持式经皮探头的节奏来确认。几项研究的结果表明,SSR和导线定位的手术结果相似。SSR提供了操作优势,因为放射科医生对反射器放置的调度与手术脱钩,但与导线定位相比成本增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Savi-Scout Radar Localization: Transitioning From the Traditional Wire Localization to Wireless Technology for Surgical Guidance at Lumpectomies

Breast-conserving surgery or lumpectomy requires localization of the lesion prior to surgery, which is traditionally accomplished by imaging-guided wire localization. Over the last decade, alternatives to wire localization have emerged. This work reviews the literature on one such wireless technology, SaviScout radar (SSR) system, and shares our experience with using this technology for presurgical tumor localization. The SSR surgical guidance system is non-radioactive. The radiologist implants a reflector device in the breast under mammography or ultrasound guidance at any time prior to surgery. The placement of this reflector can be confirmed from the cadence of a handheld percutaneous probe of a handpiece and console system. Results from several studies show that the surgical outcomes from SSR and wire-localization are similar. SSR provides operational advantages as the scheduling for reflector placement by radiologists is decoupled from surgery, but at an increased cost compared to wire-localization.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.60
自引率
0.00%
发文量
49
审稿时长
6-12 weeks
期刊介绍: Seminars in Ultrasound, CT and MRI is directed to all physicians involved in the performance and interpretation of ultrasound, computed tomography, and magnetic resonance imaging procedures. It is a timely source for the publication of new concepts and research findings directly applicable to day-to-day clinical practice. The articles describe the performance of various procedures together with the authors'' approach to problems of interpretation.
期刊最新文献
Evaluating Acute Pulmonary Changes of Coronavirus 2019: Comparative Analysis of the Pertinent Modalities COVID-19 Neuroimaging Update: Pathophysiology, Acute Findings, and Post-Acute Developments The Financial Impact of COVID on Radiology Health Systems The Impact of COVID on Health Systems: The Workforce and Telemedicine Perspective Chronic Chest Computed Tomography Findings Following COVID-19 Pneumonia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1