Bart Doyen, Gilles Soenens, Blandine Maurel, Adrien Hertault, Lauren Gordon, Peter Vlerick, Frank Vermassen, Teodor Grantcharov, Isabelle van Herzeele
{"title":"使用黑盒系统评估混合室血管内团队的表现:一项前瞻性队列研究。","authors":"Bart Doyen, Gilles Soenens, Blandine Maurel, Adrien Hertault, Lauren Gordon, Peter Vlerick, Frank Vermassen, Teodor Grantcharov, Isabelle van Herzeele","doi":"10.23736/S0021-9509.22.12226-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The hybrid room (HR) is a complex, high-risk environment, requiring teams (surgeons, anesthesiologists, nurses, technologists) to master various skills, including the 'As Low As Reasonably Achievable' principle of radiation safety. This prospective single center cohort reports the first use of the Operating Room Black Box (ORBB) in a HR. This medical data recording system captures procedural and audio-visual data to facilitate structured team performance analysis.</p><p><strong>Methods: </strong>Patients planned for endovascular repair of an infrarenal abdominal aortic aneurysm (EVAR) or treatment of symptomatic iliac-femoral-popliteal atherosclerotic disease (Peripheral Vascular Interventions or PVI) were included. Validated measures and established assessment tools were used to assess (non-)technical skills, radiation safety performance and environmental distractions.</p><p><strong>Results: </strong>Six EVAR and sixteen PVI procedures were captured. Technical performance for one EVAR was rated 19/35 on the procedure-specific scale, below the 'acceptable' score of 21. Technical skills were rated above acceptable in all PVI procedures. Shared decision making and leadership were rated highly in 12/22 cases, whereas surgical communication and nurses' task management were rated low in 14/22 cases. Team members rarely stepped back from the C-arm during digital subtraction angiography. Radiation safety behavior was scored below 'acceptable' in 14/22 cases. A median (interquartile range) number of 12 (6-23) auditory distractions was observed per procedure.</p><p><strong>Conclusions: </strong>The ORBB facilitates holistic workplace-based assessment of endovascular performance in a HR by combining objective assessment parameters and rating scale-based evaluations. Strengths and weaknesses were identified in team members' (non-)technical and radiation safety practices. This technology has the potential to improve vascular surgical practice, though human input remains crucial. (NCT04854278).</p>","PeriodicalId":50245,"journal":{"name":"Journal of Cardiovascular Surgery","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessing endovascular team performances in a hybrid room using the Black Box system: a prospective cohort study.\",\"authors\":\"Bart Doyen, Gilles Soenens, Blandine Maurel, Adrien Hertault, Lauren Gordon, Peter Vlerick, Frank Vermassen, Teodor Grantcharov, Isabelle van Herzeele\",\"doi\":\"10.23736/S0021-9509.22.12226-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The hybrid room (HR) is a complex, high-risk environment, requiring teams (surgeons, anesthesiologists, nurses, technologists) to master various skills, including the 'As Low As Reasonably Achievable' principle of radiation safety. This prospective single center cohort reports the first use of the Operating Room Black Box (ORBB) in a HR. This medical data recording system captures procedural and audio-visual data to facilitate structured team performance analysis.</p><p><strong>Methods: </strong>Patients planned for endovascular repair of an infrarenal abdominal aortic aneurysm (EVAR) or treatment of symptomatic iliac-femoral-popliteal atherosclerotic disease (Peripheral Vascular Interventions or PVI) were included. Validated measures and established assessment tools were used to assess (non-)technical skills, radiation safety performance and environmental distractions.</p><p><strong>Results: </strong>Six EVAR and sixteen PVI procedures were captured. Technical performance for one EVAR was rated 19/35 on the procedure-specific scale, below the 'acceptable' score of 21. Technical skills were rated above acceptable in all PVI procedures. Shared decision making and leadership were rated highly in 12/22 cases, whereas surgical communication and nurses' task management were rated low in 14/22 cases. Team members rarely stepped back from the C-arm during digital subtraction angiography. Radiation safety behavior was scored below 'acceptable' in 14/22 cases. A median (interquartile range) number of 12 (6-23) auditory distractions was observed per procedure.</p><p><strong>Conclusions: </strong>The ORBB facilitates holistic workplace-based assessment of endovascular performance in a HR by combining objective assessment parameters and rating scale-based evaluations. Strengths and weaknesses were identified in team members' (non-)technical and radiation safety practices. This technology has the potential to improve vascular surgical practice, though human input remains crucial. (NCT04854278).</p>\",\"PeriodicalId\":50245,\"journal\":{\"name\":\"Journal of Cardiovascular Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.23736/S0021-9509.22.12226-3\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S0021-9509.22.12226-3","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Assessing endovascular team performances in a hybrid room using the Black Box system: a prospective cohort study.
Background: The hybrid room (HR) is a complex, high-risk environment, requiring teams (surgeons, anesthesiologists, nurses, technologists) to master various skills, including the 'As Low As Reasonably Achievable' principle of radiation safety. This prospective single center cohort reports the first use of the Operating Room Black Box (ORBB) in a HR. This medical data recording system captures procedural and audio-visual data to facilitate structured team performance analysis.
Methods: Patients planned for endovascular repair of an infrarenal abdominal aortic aneurysm (EVAR) or treatment of symptomatic iliac-femoral-popliteal atherosclerotic disease (Peripheral Vascular Interventions or PVI) were included. Validated measures and established assessment tools were used to assess (non-)technical skills, radiation safety performance and environmental distractions.
Results: Six EVAR and sixteen PVI procedures were captured. Technical performance for one EVAR was rated 19/35 on the procedure-specific scale, below the 'acceptable' score of 21. Technical skills were rated above acceptable in all PVI procedures. Shared decision making and leadership were rated highly in 12/22 cases, whereas surgical communication and nurses' task management were rated low in 14/22 cases. Team members rarely stepped back from the C-arm during digital subtraction angiography. Radiation safety behavior was scored below 'acceptable' in 14/22 cases. A median (interquartile range) number of 12 (6-23) auditory distractions was observed per procedure.
Conclusions: The ORBB facilitates holistic workplace-based assessment of endovascular performance in a HR by combining objective assessment parameters and rating scale-based evaluations. Strengths and weaknesses were identified in team members' (non-)technical and radiation safety practices. This technology has the potential to improve vascular surgical practice, though human input remains crucial. (NCT04854278).
期刊介绍:
The Journal of Cardiovascular Surgery publishes scientific papers on cardiac, thoracic and vascular surgery. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, therapeutical notes, special articles and letters to the Editor.
Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (www.icmje.org). Articles not conforming to international standards will not be considered for acceptance.