{"title":"无缓冲器软开关单级30高频链路DC-AC变换器主动整流的一种新型调制策略","authors":"Anirban Pal, K. Basu","doi":"10.1109/APPEEC.2017.8309011","DOIUrl":null,"url":null,"abstract":"This paper proposes a novel modulation strategy for active rectification of a single stage, isolated, three-phase high frequency link DC-AC converter. The proposed modulation strategy results in zero voltage switching (ZVS) of the DC side converter and zero current switching (ZCS) of AC side converter at all operating conditions without using additional snubber circuit. The technique also ensures magnetic flux balance of transformer within a switching cycle. High frequency transformer (HFT) flux balance results in significant reduction in size and weight and hence improves power density. The paper presents a detailed description of the proposed modulation strategy for unity power factor (UPF) operation. Important simulation results are shown to verify the converter operation.","PeriodicalId":247669,"journal":{"name":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"27 5","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"A novel modulation strategy for active rectification of a snubber less soft-switched single stage 30 high frequency link DC-AC converter\",\"authors\":\"Anirban Pal, K. Basu\",\"doi\":\"10.1109/APPEEC.2017.8309011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a novel modulation strategy for active rectification of a single stage, isolated, three-phase high frequency link DC-AC converter. The proposed modulation strategy results in zero voltage switching (ZVS) of the DC side converter and zero current switching (ZCS) of AC side converter at all operating conditions without using additional snubber circuit. The technique also ensures magnetic flux balance of transformer within a switching cycle. High frequency transformer (HFT) flux balance results in significant reduction in size and weight and hence improves power density. The paper presents a detailed description of the proposed modulation strategy for unity power factor (UPF) operation. Important simulation results are shown to verify the converter operation.\",\"PeriodicalId\":247669,\"journal\":{\"name\":\"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"volume\":\"27 5\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APPEEC.2017.8309011\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC.2017.8309011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文提出了一种新的调制策略,用于单级隔离三相高频链路DC-AC变换器的主动整流。该调制策略在不使用附加缓冲电路的情况下,可实现直流侧变换器零电压开关(ZVS)和交流侧变换器零电流开关(ZCS)。该技术还保证了变压器在一个开关周期内的磁通平衡。高频变压器(HFT)磁通平衡显著减小了尺寸和重量,从而提高了功率密度。本文对所提出的单位功率因数(UPF)调制策略进行了详细的描述。给出了重要的仿真结果来验证变换器的运行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A novel modulation strategy for active rectification of a snubber less soft-switched single stage 30 high frequency link DC-AC converter
This paper proposes a novel modulation strategy for active rectification of a single stage, isolated, three-phase high frequency link DC-AC converter. The proposed modulation strategy results in zero voltage switching (ZVS) of the DC side converter and zero current switching (ZCS) of AC side converter at all operating conditions without using additional snubber circuit. The technique also ensures magnetic flux balance of transformer within a switching cycle. High frequency transformer (HFT) flux balance results in significant reduction in size and weight and hence improves power density. The paper presents a detailed description of the proposed modulation strategy for unity power factor (UPF) operation. Important simulation results are shown to verify the converter operation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A novel modulation strategy for active rectification of a snubber less soft-switched single stage 30 high frequency link DC-AC converter Implementation of social spider optimization for optimized hydel-thermic operational delineation Frequency Response Analysis (FRA) in power transformers: An approach to locate inter-disk SC fault Fault estimation with analytical cable model for MMC-HVDC in offshore applications Modified current control technique for grid synchronization in voltage source converters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1